Week 2
Planning and troubleshooting on the design of smart inverter
Planning and troubleshooting on the design of smart inverter
This Smart Inverter is based on an Intelligent Power Module (IPM). The gate signals are provided via Texas Instruments micro controller C2000.
IPM FSBB20CH60F
Module: https://www.digikey.com/en/products/detail/on-semiconductor/FSBB20CH60F/1127360
Data Sheet: www.onsemi.com/pub/Collateral/FSBB20CH60-D.pdf
Texas Instruments LAUNCHXL-F28379D
IPM FSBB20CH60F
LAUNCHXL-F28379D
Figure: Circuit diagram of the smart inverter
Design of the smart inverter is done by a previous student.
The prototype showed different improvements to this inverter
Additional resisters must be connected for opto-couplers
The current paths should be enlarged to reduce heating