Detecting CS2 Dark (Front Access Type: Reject box is opened.) | Health Check Req
Error caused by dust on optic / glass sensor. Find sensor at front top of dispensor by just opening reject box and seeing lever is actuated by reject door. When door is closed sensor is visable. Look close from top. I can usually touch the sensor to rub off dust with the little finger on my left hand. Good to wipe dust off those anyway. Error is also sometimes caused by torn piece of bill. Fixed.
WE NOW HAVE SEVERAL WINCE 7.0 ATM that I know of.
WinCE 7.0 Integrated I/O-Mainboard (THIS) - OS Version: v10.11.10 or higher (began manufacturing in 2022)
WinCE 7.0 Integrated I/O-Mainboard
Part Number: S7650000289 or S7650000330
Part Number (for ATMs w/ Touch Function Keys): S7650000317 or S7650000323
PHOTO BELOW IS WinCE 7 Mainboard its "ONE" board
Win7 Software loading instructions
Hold down the boot menu button and press and release reset button to access boot menu.
Photo below is older WinCE 6.0 Mainboard on top of board
Please send me a email at tgately@bfcenterprises.com . I have a return email prepared with links to get the latest Kahuna/Cardtronics + software.
Jun 01, 2022
New for Hyosung SE
*PLEASE IDENTIFY YOUR MAINBOARD TYPE BEFORE LOADING SOFTWARE**
*PLEASE IDENTIFY YOUR MAINBOARD TYPE BEFORE LOADING SOFTWARE**
Apart from the physical differences (see picture of WinCE 7.0 Integrated I/O-Mainboard at top), SE Mainboards can also be identified by the "OS Version" found in the REPORT > S/W VERSION menu:
-WinCE 6.0 Mainboard - OS Version: v06.01.19 or lower
-WinCE 7.0 Integrated I/O-Mainboard (At Top) - OS Version: v10.11.10 or higher (began manufacturing in 2022)
WinCE 7.0 Integrated I/O-Mainboard
Part Number: S7650000289 or S7650000330
Part Number (for ATMs w/ Touch Function Keys): S7650000317 or S7650000323
A recent technical bulletin was launched to inform our customers about the new WinCE 7.0 mainboard for our Retail ATMs. The new mainboard does not have a separate I/O board like the WinCE 6.0 mainboard required. The WinCE 7.0 mainboard and I/O board are “combined” so it is only one part. The new WinCE 7.0 mainboard will be installed on new production retail ATMs in Q1 2022. Advantages to moving to this new mainboard are:
The updated hardware and WinCE7 have better performance than the previous generations
Updates from the cloud software repository take less than a minute in most cases
Previous generation mainboards are no longer available for purchase or warranty replacement.
For any new Retail ATMs manufactured after Q1 2022 there is no action that needs to be taken. For existing ATMs in production today the mainboards will need to be replaced.
The WinCE 7.0 mainboard does not use the same software as the WinCE 6.0 mainboard. The WinCE 7.0 Software (OS, BL, and AP) is available for download on our website, www.nhatm.com. The instructions to load the software via SD card and/or USB are very similar to that of the WinCE 6.0 mainboard. Also, the loading instructions are included in the software download from our website.
Minimum SW Required for the new WinCE 7.0 mainboard:
OS : V10.11.07 and up (note: WINCE60 version structure is V08.xx.xx)
BL : V10.02.07 and up
AP : V06.02.09 and up
Please contact your Hyosung account representative to help you determine the appropriate board needed for your specific ATM model and to plan this upgrade.
****************************************************************************************************
I asked grok what does aid list mean in regards to Hyosung atm emv aid list.
aid list (application ID) description from grok
In the context of EMV (Europay, Mastercard, and Visa) technology for Hyosung ATMs, an AID list refers to the configured list of Application Identifiers (AIDs) supported by the ATM terminal.
Key Concepts:
• What is an AID?
An AID is a unique hexadecimal code (typically 5–16 bytes long) that identifies a specific payment application on an EMV chip card, such as a Visa credit application (AID: A0000000031010) or a Mastercard debit application (AID: A0000000041010). It consists of a Registered Application Provider Identifier (RID, assigned by EMVCo to card schemes like Visa or Mastercard) and a Proprietary Application Identifier Extension (PIX, specific to the application). AIDs enable the ATM to select and interact with the correct payment app on the card during a transaction.
• What is the AID List?
The AID list is a predefined set of AIDs that the ATM terminal (in this case, a Hyosung model like the NH1800, NH2700, or Halo series) is programmed to recognize and support. During an EMV transaction:
1. The card presents its available applications (via the card’s Payment System Environment or PSE).
2. The ATM compares these against its AID list to build a “candidate list” of matching applications.
3. It selects the highest-priority match (based on configuration) to proceed with the transaction, such as authorizing a withdrawal.
This ensures compatibility with various card issuers and networks, preventing fallback to insecure magnetic stripe processing. Without a properly configured AID list, the ATM may reject valid EMV cards or fail to route transactions correctly.
Specific to Hyosung ATMs:
Hyosung (now Nautilus Hyosung) ATMs require software updates and configuration adjustments to enable EMV, including loading or enabling the AID list. For example:
• In the operator menu (accessed via master/service password), navigate to System Setup > Optional Function 1 > EMV to toggle the AID list (e.g., “Enable All AIDs” or disable specific CDS said ones like #1, #13-16 , 20 for Columbus Data/Midwest Money processors).
• This is part of EMV certification and often involves updating to the latest firmware (e.g., for models like the 1500 or 2700) to comply with PCI and EMV Level 1/2 standards.
• Common AIDs in ATM configs include those for Visa, Mastercard, Discover, and regional debit networks (e.g., STAR or NYCE). A full list of standard AIDs can be referenced from EMVCo specifications, but Hyosung configs are tailored by the ATM deployer or processor.
If your Hyosung ATM shows EMV-related errors (e.g., card read failures), check the AID list configuration first, as mismatches are a frequent issue. For model-specific manuals, consult Hyosung’s support or your processor.
*****************************************************************************************************
*********************************************************************************************************
ROCKITCOIN Bitcoin link / Form to fill out after / while job is completed. Will give some troubleshooting ideas as you fill out form. May help to fix Kiosk.
LINK -->>FOR Rockitcoin repair only.
*********************************************************************************************************
Every time I reprogram a Hyosung atm I have to remember this to get master password reset
When the Please Wait While Initializing Screen comes up you will have roughly 5 seconds to enter in:
usually have to make sure atm makes ding noise on first key press.
MASTER PASSWORD RESET KEY SEQUENCE
*** Clear > Left Arrow > Right Arrow > Clear > Clear > Cancel***
**********************************************************************************************************
USB update SE--> Most used, C06.02.06 SE USB Update for Hyosung Atms that are SE Like 1800SE 1800SE, 2700CE, 2700T, 4000W, 5000SE, Force, Halo, Halo II, Halo-S
USB update CE Older Atms CE ends in .38 USB update for Hyosung atms with CE in Model number like 1800 CE 1800CE, 5000CE, 5300CE
SD Card OS for SE--> US_V060208_OS_BL_SDCard Hyosung Atms that are SE Like 1800SE 1800SE, 2700CE, 2700T, 4000W, 5000SE, Force, Halo, Halo II, Halo-S
SD Card OS for SE SD Card ends 11 new 11-7-2023 Hyosung Atms that are SE Like 1800SE 1800SE, 2700CE, 2700T, 4000W, 5000SE, Force, Halo, Halo II, Halo-S
SD Card OS for CE New Revision CE Model SD Card Full Hyosung atms with CE in Model number like 1800 CE 1800CE, 5000CE, 5300CE
Use C06.02.06 for Hyosung SE Atms. Like 1800SE. (Not to be confused with windows software called CE)
Once the software version is changed on atm from Factory Version which starts with a "V" to Cardtronics/KAHUNA/NCR Version which starts with a "C" The settings below are available.
1.)Customer option 1/Balance/Enable all
2.)Customer/Standard 1 option/Disable local surcharge, check 1st Call is disabled
3.)Customer option 1 / other / TDL option / all enabled fee is $1.00 dollar dual balance enabled
This fee charges an extra dollar when customer uses a regular credit card and not a debit card on Atm.
*********************************************************************************************************
RMS Setup Remote Monitoring System
*********************************************************************************************************
CDU binding is now “enabled” by default in software version AP V06.02.10, which was released on 02/18/22.
Unbind HYOSUNG Dispenser screen error -400BC(00) or 400BC00
For 4K dispenser with reset button below dip switches <--click link
Short jumper on dispenser for 1K dispenser below
Atm off, short jumper 7+8 or 1+2 , power up atm for 20 seconds. Power down, remove jumper, boot up normally.
*********************************************************************************************************
How to program Hyosung ATM
Use below link to program Atm Standard 1 these setting work for a Atm that connects using locations internet.
Toms BFC Hyosung Master Password reset NEED VAULT DOOR OPEN FOR MASTER PASSWORD RESET TO APPEAR.
After setting parameters above, use below link for Atms that communicate with Systech or I-4100 or opt-connect
Standard 1 programming notes for regular Hyosung BFC ATMs
These 2 links above are for programming a Hyosung Atm that is new or has just been formatted.
************************************************************************************************************
How to program Genmega ATM. Atm side is on page 10-13 of this PDF.
Other info in PDF is on updating software and Libertyx bitcoin configuration.
************************************************************************************************************
For Atm software--->>> Go to Atmequipment.com and make your own user, then download directly from there. Choose 1800 SE for that model or 1800 CE.
I formerly had software for download available here but got a strange threatning email concerning content on my google site from Huang, Chin Chao <s1xpence.cs08@nctu.edu.tw> suggesting I take this whole page down or at least the proprietary software downloads. I just removed the download links. You can still download the proprietary factory software from atmequiptment.com
**********************************************************************************
Hyosung Libertyx Bitcoin.
Needs 8000 keypad. SE ATM not CE. C software ending.06. One set of DES Keys. Kahuna Instructions.
Suggests -->For software update COPY NVRAMM settings onto USB first in case of crash.
Must DO --> atm.Libertyx.com page 6 number 4 change API URL to atm.libertyx.com from libertyx.com
Dont change anything on standard 1 standard 3 when you call in to columbus data say standard 3 for Libertyx Terminal ID.
Dont change any communications settings
When it says epp error at end just reboot.
Kahuna Libertyx bitcoin instructions
3-11-2025 Libertyx Terminal IDs new edited at bottom
********************************************************************
Triton RL 3.2.3 full install to make DCC work just copy this one file to USB
You know its a BFC --> Cardtronics ATM if the terminal ID starts P314. Cardtronics USB updates. First use factory version sdram. Then Cardtronics USB updates to change Version V.xx to C.38. We only have about 0 Atms that are Cardtronics. Cardtronics ATMs are programmed standard 1. Enhanced Standard 1. All regular BFC/NCAL Atms were programmed standard 3. We have switched all Hyosung Atms to standard 1, enabling DCC and online Journal, enabling RMS. When calling in keys to Columbus Data say Enhanced Standard 1 if its Cardtronics or BFC/NCAL now.
Cardtronics Enhanced Standard 1 programming guide
****************************
Toms BFC Hyosung Programming guide Standard 1 same as top of page
For latest software update
BACKUP settings to USB before software update
11-02-2021
Software update C06.02.02 Don't install .02 locks up on screen where you enter pin. Use C06.02.06 or newer.
1.)Customer option 1/Balance/Enable all
2.)Customer/Standard 1 option/Disable local surcharge
3.)Customer option 1 / other / TDL option / all enabled fee is $1.00 dollar dual balance enabled
*****************************
Hyosung said OS version should be .19 When updating with SDRAM OS Version also gets updated.
Need vault door open to get master password reset screen.
Usually reload software from SDRAM then reset master password.
On newer SE software may I have to do SDRAM then update from USB.
At end need to reset dispenser because of CDU Binding if error 400BC
SE and [CE (below)] master password reset
Link to SE Instructions from update (GOOD)
Dip switches for SE normal operation 2 off 1,3,4 on. On board without battery.
Switch dipswitch 4 to get diagnostics
Flip dipswitch 4. Reboot. Insert correct sdram card.
Choose update or format. Format will fix stuff.
May have to re enter all. Back up settings to USB first.
Enter correct Terminal ID to restore settings.
or
Enter settings from Setup Sheet.
SE master password reset
SE Power the machine off, remove the SD Card, open the vault door (do not touch the vault door position
switch) and then power it back on.
23. Watch the screen for the Please Wait While Initializing Screen, NOT the Please wait while loading
screen.
24. When the Please Wait While Initializing Screen comes up you will have roughly 5 seconds to enter in:
SE *** Clear > Left Arrow > Right Arrow > Clear > Clear > Cancel***
Note: once the Master Password Reset is complete and you can log
in with the default Master Password 555555 you can close the Vault Door if you wish.
***CE master password reset hold top 2 left buttons while booting takes a while.
on CE hold bottom 2 left buttons to enter diagnostics mode.
Enable Health Check
Unnecessary Debit / Debit Mastercard screen on ATM during tranaction. To disable.
On a regular Hyosung ATM the setting is under Customer/Optional Function 2/EMV/Other Options/Use Common Aid/ Enable.
When I enable use common aid this screen does not show on our Hyosung ATMs.
Standard 1 programming notes for regular Hyosung BFC ATMs
5100T thru the wall ATM programming notes
5100 T boots shuts down windows and goes to blank screen. This was caused by backup batteries. Solution replace 4 backup batteries .
Problem 5100T goes to operator mode on reboot. 5100T reboots into operator mode.
Problem was back up batteries in bottom have gotten weak.
Fix There are four 12 volt batteries. If you buy replacements Batteries Plus carries them and called them "Twelve, eight, F." 12 8 F.
Fix 2 Cherry switch was broken in vault area. Their is a 4 wire 6 terminal cherry switch telling atm open closed status of vault door.
Cherry switch was physically broken.
Fix 3 we jumped the cherry wswitch. Connected 2 wires black and yellow on right. Also connected 2 wires black and yellow on left.
This error persisted for years until I changed the backup batteries again and noticed cherry switch broken.
Every Monday morning atm needed to be reset from operator mode to put it back in sercive by switching rocker switch on back panel.
When 5100T losses power if back up batteries are strong enough the PC performs a proper shutdown. Then on reboot the ATM comes back into service and works instead of coming into operator mode. When the batteries are weak PC shuts down immediately and reboots into operator mode until service person flips switch and puts ATM back into service.
Check wires are pushed onto battery terminals correctly.
5100T Software installation manual win 10 and win 7.
**********************************************************************************************
This worked for sure on one machine. Maybe two. regedit fix to make 5100T atm come into service
There is an “Always in service” registry that can be changed. It is found in:
HKEY_LOCAL_MACHINE\\Software\\ATM\\Devinfo
TTU
“AllWaysInService"=dword:00000001
Check to see if this is changed to that value.
Regards,
The Hyosung America Support Team
*******************************************************************
***********************************************************************
5100T Windows boot error
windows Boot Manager
Windows failed to start. A recent hardware or software change might be the cause. To fix the problem:
1. Insert your windows installation disc and restart your computer. 2. Choose your language settings, and then click "Next."
3. Click "Repair your computer."
If you do not have this disc, contact your system administrator or computer manufacturer for assistance.
File: \windows\system32\config\system
status: 0xc00000e9
Info: Windows failed to load because the system registry file is missing, or corrupt.
ENTER Contine
ESC-EX11
**************************************************************************
5100T Windows boot manager screen
I called Hyosung tech support after first windows error. They said needs full software reload.
Tried reloading software unsuccessfully many times.
Windows error changed to device unacessable.
Finally checked backup batteries in bottom one was corroded leaking and reading zero volts.
Replaced backup batteries.
Found another working 5100T with same pc part number and same version bios.
Copied that drive to a ssd.
Brought ssd to out of order location.
It booted.
Just had to change name on receipt, serial number, and amount of bills. Also got the BC 400 error but after resetting dispenser atm was functioning.
*******************************************************************************
Cencon installation instructions
Cencon change combo
power up lock Dial left ccw, enter combo ,Opr Dial right cw retract bolt ,open vault.
insert change wire
turn dial right cw extends bolt with vault door still open
Press #8
enter old combo
enter new combo twice.
Pull out change wire test with vault open.
if error reverts to original combo.
Cencon Change combo instructions from manual
1. Power Lock g EC
Turn the Dial to the left (CCW) until “EC” (Enter Combination) is displayed.
2. EC g Enter Shelved Mode Combination g OPr
Enter the current Shelved Mode combination (either 50-25-50 or a changed
Shelved Mode combination) by sequentially pressing those digits on the lock
keypad. The numbers will be displayed on the LCD as they are entered.
3. OPr g Retract Bolt
Turn the Dial to the right (CW) to retract the bolt
4. Open Door
5. Insert Change Key
Insert the change key into the change key socket on the back of the lock.
6. Extend Bolt
Do not close the door. Turn the Dial to the left (CCW) to extend the bolt.
7. Power Lock g EC
Turn the dial to the left (CCW) until EC (the Change Key symbol along with
Enter Combination) is displayed.
8. EC g Press #8 g EcF
Press the “#” button followed by the “8” button. EcF (Enter current Factory
combination) will be displayed.
9. EcF g Enter Current Shelved Mode Combination g EnF
Enter the current shelved mode combination, “EnF” (Enter new Factory
combination) will be displayed.
10.EnF g Enter New Factory Combination g Cnf
Select and enter the new combination. “CnF” (Confirm new Factory combination)
will be displayed.
Note: The new Shelved Mode combination should be recorded and stored
in a secure area.
11.CnF g Confirm new Factory combination g POC
Enter new combination again to confirm. POC (Pull Out Change key) will
be displayed.
12.POC g Remove Change Key g EOP
Remove the change key. EOP (End OPeration) is displayed.
13.EOP g Power Lock g EC
Turn the dial to the left (CCW) until EC (Enter Combination) is displayed.
14.EC g Enter New Shelved Mode Combination g OPr
Enter the new shelved mode combination by pressing those digits on the lock’s
keypad. The numbers will be displayed on the LCD as they are entered.
15.OPr g Retract Bolt
Turn the Dial to the right (CW) to retract the bolt.
16.Close Door
17.Extend Bolt
Turn the Dial to the left (CCW) to extend the bolt.
*************************************************************
Cencon lock removal instructions.
Write serial number on back of lock with sharpie #2 to get serial number.
Shelved combo 50-25-50 or if it goes IPI need to call NCAL to get combo.
Get small box and plastic baggy for parts and screws.
Lock should be in unlocked state to remove it.
1) Remove 2 screws from back of lock.
Carefully remove back plate it has a wire that needs to be unplugged attached.
Hold knob on front while unscrewing screw in center of big gear in back.
Remove gear and knob put screw to hold them together.
Remove screws from front holding on dial pad.
Remove dialpad.
Carefully dislodge ribbon cable plastic tube and remove front plate.
Four screws hold back plate.
Remove back plate.
Do not touch or damage ribbon cable.
Reverse procedure for installation.
MAS HAMILTON LOCK
To change combo
Press Enter, then 1, then old combo, then new combo twice
To open turn dial and wiggle dial till it blins charging lock. . Tab must be at 12 oclock. Enter combo. Turn to right to pull in bolt. Turn or pull handle to open. To lock close then turn dial.
Pictured below is a sidelock in locked position. Note 9v battery charging port on face of lock. If lock needs battery replaced, charge by holding 9v battery on port, then enter combo and turn lock to right to pull in bolt. Then turn handle to open. Battery located inside atm vault.
Pictured to left is sidelock in the open position. Not good to leave atm in the open position. Turn lock back up to lock.
SG lock combo reset instructions
22 star
Default #
New #
New #
To open SG lock enter combo then #
************************************************
Panty Hose Machine Peavy Tech support 813-884-3905 Tech Darrin 813-468-9412
PantyHose red button on mainboard
red button 11 3 8Meter
11 options, 4 price option, 5 column reset
11 does 1st 6 columns, 12 does second
11,5,12,6 reset 12 column <---(not sure why I put this)
11,6 reset all columns <--- USE THIS
6000 Keypad Hyosung
Keypad error 97999
Rick said one green light on replace keypad
Keypad reset this works if keypad lags sometimes.
Switch machine off
On Keypad Switch dip SW 1 on
Switch machine back on 5 seconds
Turn machine off
Switch dip 1 back off
Turn machine back on
re enter keys in keypad
Hyosung 8000 keypad instructions best to call Hyosung tech support 877-496-7864 and have them talk you through it.
PCI = Payment Card Industry. EPP = Encrypting Pin Pad. 8000 Keypad is PCI 3.0. 6000 Keypad is PCI 1.0.
Hyosung X1 Keypad instructions Physical installation
Hyosung X1 Keypad instructions Menu installation
X1 keypad PCI 5 Payment Card Industry
8000 Keypad PCI 3
6000 Keypad PCI 1
All keypads one greeen light bad. Needs flashed. BAD
X1 Keypad. Forget edit key password, needs re-flashed. BAD -->Send in for repair.
X1 and 8000 need old edit key passwords. And new change state passwords
6000 and 8000 reset with dipswitch.
X1 does not do reset with dipswitch. In menu choose epp reset or clear.
If Secure mode passwords are lost on X1 <-- send in for repair.
If change state passwords are lost try reset keypad in menu.
Clear EPP default change state passwords become 000000.
default passwords 000000 inside key after first passwords (Make first passwords inside key the normal ones)
for keypad state change key passwords from 000000 to 5's, and 6's.
Change state on keypad from initialization state to installation state.
1) Installation State The Installation State is the default operational state for the EPP. This state is required for the EPP to accept a Master Key and for transactions to be processed. This state is the same as the default for the PCI 1.0 EPP.
4) Initialization State This is the default state of the EPP after performing a physical NVRAM clear on the EPP. All passwords and accounts are reset to default zeroes (000000) and must be reconfigured prior to key entry / normal ATM operations. You must change the EPP State accounts and passwords from default, and log in successfully to change from this state
Directions for setting 8000 and X1 keypads.
Host,Edit Key, set epp state. Enter id 1 and 2 default all zeros. Add Id make id 1 all 5,s and id 2 all 6's. Back out go into set epp state again with the new ids. Shows initialization state. Choose change state. Changes to installation state.
Back out to host. Back in edit key change initial passwords from all zeros to our usual edit key passwords.
Be sure mode is tdes 3. In edit key choose master key triple and enter des keys as usual.
Tech support numbers
Hyosung tech support 877-496-7864
Columbus Data Tech Support 888-275-2864 Help if not connecting
ATM Store . com Systech 877-977-8020
ENCORE Tech support 703-433-6329
Triton Tech Support 288-868-1317
Cardtronics Tech Support 800-786-9666
MAYA Tech Support Phillips 66 Lindell Daniel Yeh cell 909-305-3052 email danielyeh@maya.tech prefers emails sometimes answers quickly
For all other questions my cell is 314-575-6470 =Tom cell I fix ATMs for fun and will help you out anytime for free or maybe a small fee.
Thanks and good luck ATM fixin
************************************************************************************
Systech wireless Box Settings and DCC info.
********************************************************************************************************************
Encore e1000 use lan
Processor standard3 or Standard 1
Type tcp/ip
Top ip type visa framed
VISA framed option no enq / eot required
Ssl tls enabled
Certificate disabled
System
DHCP enabled ,sets IP itself
Ip 192.168.10.187
Gateway 192.168.10.1
Sub 255.255.255.0
Dns 192.168.10.1
Hosts
Url enable
Host 1 2 Atm.columbusdata.net
Port 1 2 6963
These setting work for Standard 3 or Standard 1. Later directions for encore say use Standard instead of visa framed. On Standard those settings for enq/eot do not show.
********************************************************************************************
Source: National ATM Council. Effective April 13, 2019, all ATM owners and operators will be able to offer Dynamic Currency Conversion (DCC) services to their customers in the U.S. DCC is permitted today by MasterCard at U.S. ATMs and represents a meaningful revenue stream for many ATM providers. I think it means we now charge a fee to people with foreign cards.
TRITON Printer settings CONFIG TERMINAL / Printer settings
TRITON Default password key management 12345678 for both
Triton RL 3.2.3 software or greater for DCC
Probably has to be 3.2.3 Plus Joe got off Kahuna website.
I put on RL software for download in link below
copy file xd34xuce3.2.3j.tfv to USB
New default password after software update 001234
password 4,1, just (normal 6 digit default menu password) it puts 00 itself?
1)Copy ATM config file to USB 8,6, (note TID filename it makes)
2)Software update 5,7,
3)Restore config file 8,7
Select bill thickness ter 6,4,9
Enter Denomination in 7? 2000 denomination shows $20.00
print all setup 6,8, 3 to print
shows DCC enabled at bottom
Call CDS if its not listed as RL on Columbus data
Done?
All Standard 1 Hyosung comms ID CDHY
If changing setting on Triton Columbus Data told me to set communications ID to CDSAA0 <--(WRONG).
We found that Triton communications ID has to be set ATMI00 (atm eye zero zero)
To enable Health check on Triton.
Press Blank key and numeral key 1 at same time to enter menu password screen.
Menu password is 00 then default six digit regular menu password.
Press 0 main menu.
6 Terminal config
1 General Parameters
0 Checked to enable heartbeat
F1 which is upper left function key by screen
Set F1 to 120 for a 2 hour call in
Press enter to leave screen and save new setting
other tip F8 enables on screen Triton keypad then blank key for CAPS
Triton said error 621 replace keypad
EPROM ERROR RECOVERY After initial installation and software download, you “may” experience a “hard” 205 or 239 Error Code. You will have to reboot the terminal of which you will get this screen (below, left). CLEAR TAMPER -
This option is only displayed if the terminal has detected a tamper condition from the SPED device. CLEAR SERIAL TAMPER - This option is only displayed when the serial number of the SPED device does not match the SPED device serial number that the terminal has stored. This is not a SPED device tamper but an indication that the terminal may have been tampered with. When this error is cleared, the serial number of the connected SPED device is written to the terminal .
If this screen has either the SPED Tamper Error Code 205 or SPED Serial Number Error Code 239, the reset error button will not clear these 2 errors. To clear the errors, enter
MANAGEMENT FUNCTIONS > DIAGNOSTICS > MORE DIAGNOSTICS > MORE(MORE) DIAGNOSTICS > KEYPAD. Need to find keypad. Maybe under first diagnostics.
This menu option is dynamic. The clear error codes (Tamper or Serial) will only appear when either error is detected on the terminal.
HYOSUNG ADVERTISEMENT SCREEN LOGO NOTES
Copy files to usb with this folder structure.
Insert USB run software update.
Different folder structure for SE or CE
SE = UPDATE/NH2700CE/PATCH/ADVERTISEMENT/1024_600/ADV_01.JPG
CE = UPDATE/PATCH/ADVERTISEMENT/ADV_01.JPG
ON MENU UNDER CUSTOMER WELCOME ADVERTISEMENT ENABLE 01 FOR ONE NAME IT 02 FOR TWO.
file needs for NH2700 which is an SE
1024x600 pixels
72 DPI
24 Bit Color
JPEG Format
Maximum file size 500kb