Surface measurement techniques such as pressure-sensitive paint (PSP), temperature-sensitive paint (TSP), and infrared thermography allow for higher spatial resolution measurements than conventional point sensors. These techniques can measure surface pressure, oxygen concentration adjacent to the wall, surface temperature, and heat flux. There are a wide variety of applications across all flow regimes, ranging from acoustics, gas turbine blade cooling, and hypersonic aerodynamics to name a few.
PSP and TSP leverage luminophores that can be excited by light at particular wavelengths. These luminophores emit light at a higher wavelength, and the intensity of this light is proportional to the temperature of the luminophore and/or the oxygen concentration adjacent to it. An a priori or in situ calibration between intensity and pressure/temperature is used to back out the surface quantity of interest. IR thermography measures the thermal electromagnetic radiation emitted from a object's surface.
The DASH group looks to expand the capabilities of these established surface measurement techniques. Characteristics such as sensitivity, frequency response, and thermal stability are of particular interest. Applications of these techniques to extreme environments, such as that generated by a high-enthalpy hypersonic wind tunnel, is an emerging interest of the group.
Above Figure: Static pressure-temperature calibration for an anodized aluminum pressure-sensitive paint.