Diagnostic Information
a VBAT when heater is on; will cycle from 0 to VBAT to 0 during KOER test.
b Not used on F650/750.
c 4R100 transmission only.
d Econoline only.
e Voltage goes to 0 when water in fuel activates switch.
f Pin not used on F-Series or Excursion.
g Neutral switch — F-Series with AT545 Allison automatic transmission.
h Not used on F-series.
i F650/750 only.
j F-Series 250/550
k Output is in Hz. and varies with vehicle speed; zero Hz when stopped; 450 to 750 Hz. at 50 mph.
l Not used on Econoline.
m Voltage increases as manifold air temperature increases.
n Voltage normally 0, goes to VBAT when PTO switch is turned on and ignition is on.
o Will momentarily go to VBAT during lamp check.
p Voltage goes to VBAT if engine is not running and key is on for over 20 seconds.
q Grounded when heater is on; will cycle from VBAT to 0 to VBAT during KOER test.
r Voltage increases as fuel level increases.