N Maleki, A Safavi, F Tajabadi - Analytical chemistry, 2006 - ACS Publications
Ionic liquid, n-octylpyridinum hexafluorophosphate (OPFP) has been used to fabricate a new
carbon composite electrode with very attractive electrochemical behavior. This type of
carbon electrode has been constructed using graphite mixed with OPFP as the binder. ...
Cited by 338 Related articles All 3 versions Cite
A Safavi, N Maleki, O Moradlou, F Tajabadi - Analytical biochemistry, 2006 - Elsevier
A recently constructed carbon composite electrode using room temperature ionic liquid as
pasting binder was employed as a novel electrode for sensitive, simultaneous determination
of dopamine (DA), ascorbic acid (AA), and uric acid (UA). The apparent reversibility and ...
Cited by 209 Related articles All 4 versions Cite
N Maleki, A Safavi, E Farjami, F Tajabadi - Analytica chimica acta, 2008 - Elsevier
In this work arrays of palladium nanoparticles were synthesized on carbon ionic liquid
electrode (CILE)(Pd/CILE), and the electrocatalytic oxidation of hydrazine was investigated
using this electrode. Electrochemical oxidation of hydrazine in phosphate buffer (pH 7) ...
Cited by 84 Related articles All 4 versions Cite
A Safavi, N Maleki, F Tajabadi - Analyst, 2006 - pubs.rsc.org
A carbon ionic liquid electrode (CILE) was used for the investigation of the electrochemical
oxidation of phenolic compounds in acidic media using cyclic voltammetry,
chronoamperometry and square wave voltammetry techniques. The results indicate that, ...
Cited by 80 Related articles All 5 versions Cite
A Safavi, N Maleki, F Tajabadi, E Farjami - Electrochemistry …, 2007 - Elsevier
A simple method for the fabrication of arrays of palladium nanoparticles on carbon ionic
liquid electrode (CILE) is described. The ionic liquid, octylpyridinum hexafluorophosphate
([C8Py]+ PF6-), is incorporated in the electrode as the binder. Pd nanoparticle arrays are ...
Cited by 74 Related articles All 2 versions Cite
N Maleki, A Safavi, F Tajabadi - Electroanalysis, 2007 - Wiley Online Library
Abstract In this paper, a survey has been undertaken to clarify the possible reasons for the
electrocatalytic activity obtained by the presence of ionic liquid in carbon paste electrode
(CPE). For this purpose, the effect of the addition of traces of ionic liquid to conventional ...
Cited by 50 Related articles All 2 versions Cite
A Safavi, N Maleki, F Honarasa, F Tajabadi… - …, 2007 - Wiley Online Library
Abstract A new type of potentiometric sensor based on a recently constructed carbon ionic
liquid electrode (CILE) is described. Two kinds of ionic liquids, ie, N-octylpyridinium
hexafluorophosphate (OPFP) and 1-butyl-3-methylimidazoluim hexafluorophosphate ( ...
Cited by 47 Related articles All 3 versions Cite
A Safavi, N Maleki, F Farjami - Colloids and Surfaces A: Physicochemical …, 2010 - Elsevier
A microemulsion based on imidazolium ionic liquids (ILs), 1-octyl-3-methylimidazolium
chloride [omim][Cl], as a surfactant, a hydrophobic IL as a substitute for.
Cited by 31 Related articles All 3 versions Cite
A Safavi, N Maleki, O Moradlou - Electroanalysis, 2008 - Wiley Online Library
... Using Carbon Ionic Liquid Electrode Afsaneh Safavi,* Norouz Maleki, Omran Moradlou ... Biochem.
2006, 359, 224. [27] A. Safavi, N. Maleki, F. Tajabadi, Analyst 2007, 132, 54. [28] A. Safavi, N.
Maleki, O. Moradlou, M. Sorouri, Electrochem. Commun. 2008, 10, 420. ...
Cited by 25 Related articles Cite
A Safavi, N Maleki, O Moradlou, M Sorouri - Electrochemistry …, 2008 - Elsevier
... 21]; N. Maleki, A. Safavi, F. Tajabadi; Anal. Chem., 78 (2006), p. 3820. ... 23];
A. Safavi, N. Maleki, F. Tajabadi; Analyst, 132 (2007), p. 54. ...
Cited by 98 Related articles All 2 versions Cite
Fabrication of a glucose sensor based on a novel nanocomposite electrode
A Safavi, N Maleki, E Farjami - Biosensors and Bioelectronics, 2009 - Elsevier
... Recently, we proposed carbon ionic liquid electrode (CILE) as a high performance electrode
with many good features and provision of high rates of electron transfer ( [Maleki et al., 2006],
[Safavi et al., 2006], [Safavi et al., 2007a], [Safavi et al., 2007b] and [Maleki et al., 2007]). ...
Cited by 96 Related articles All 5 versions Cite
A Safavi, N Maleki, S Momeni, F Tajabadi - Analytica chimica acta, 2008 - Elsevier
The electrocatalytic oxidation of sulfite was investigated at carbon ionic liquid electrode
(CILE). This electrode is a very good alternative to previously described electrodes because
the electrocatalytic effect is achieved without any electrode modification. Comparative ...
Cited by 21 Related articles All 3 versions Cite
A Safavi, N Maleki, E Farjami, FA Mahyari - Analytical chemistry, 2009 - ACS Publications
Cited by 49 Related articles All 3 versions Cite
A Safavi, N Maleki, F Farjami, E Farjami - Journal of Electroanalytical …, 2009 - Elsevier
The electrocatalytic oxidation of formaldehyde on palladium nanoparticles electrodeposited
on carbon ionic liquid electrode (Pd–CILE) has been investigated. T.
Cited by 46 Related articles All 2 versions Cite
A Safavi, N Maleki, E Farjami - Electroanalysis, 2009 - Wiley Online Library
... Afsaneh Safavi,a, b* Norouz Maleki,a, b Elaheh Farjamia, b a Department of Chemistry, College
of Sciences, Shiraz University, Shiraz 71454, Iran b Nanotechnology Research Institute, Shiraz
University, Shiraz, Iran *e-mail: safavi ... 46] A. Safavi, N. Maleki, F. Tajabadi, E. Farjami ...
Cited by 36 Related articles Cite
Development of a sensitive and selective Riboflavin sensor based on carbon ionic liquid electrode
A Safavi, N Maleki, H Ershadifar, F Tajabadi - Analytica chimica acta, 2010 - Elsevier
The electrochemical properties of Riboflavin adsorbed on carbon ionic liquid electrode
(CILE) were studied by cyclic voltammetry. A film with a surface coverage of up to 3.3× 10−
9molcm− 2 was formed after 10min exposure time. Electron transfer coefficient and rate ...
Cited by 7 Related articles All 4 versions Cite
Molecular wires as a new class of binders in carbon composite electrodes
A Safavi, N Maleki, F Honarasa, F Tajabadi - Electrochemistry …, 2009 - Elsevier
A new carbon composite electrode based on the use of a molecular wire as the binder is
introduced. The composite electrode consists of graphite and diphenylacetylene (a
molecular wire). The behavior of the electrode towards different categories of compounds ...
Cited by 5 Related articles All 2 versions Cite
A Safavi, N Maleki, F Aghakhani Mahyari… - Fullerenes, …, 2013 - Taylor & Francis
... a * , Norooz Maleki a , Farzaneh Aghakhani Mahyari a & Mohammad Mahdi Doroodmand a pages
472-484. ... Maleki, N., Safavi, A. and Tajabadi, F. 2006. High-performance carbon composite
electrode based on an ionic liquid as a binder. Anal. Chem., 78: 3820–2836. ...
Cited by 1 Related articles All 2 versions Cite
SE‐30 Graphite Composite Electrode: An Alternative for the Development of Electrochemical Biosensors
A Safavi, N Maleki, F Tajabadi - Electroanalysis, 2010 - Wiley Online Library
Abstract A new graphite composite electrode was constructed by mixing graphite powder
with chromatography stationary phase, SE-30, as the binder. The electrochemical behavior
of the new electrode has been evaluated and compared with that of traditional carbon ...
Related articles All 2 versions Cite
Electrochemistry in room temperature ionic liquids: a review and some possible applications
DS Silvester, RG Compton - Zeitschrift für Physikalische …, 2006 - oldenbourg-link.com
... Afsaneh Safavi, Norouz Maleki, Safieh Momeni und Fariba Tajabadi. (2008) Highly
improved electrocatalytic behavior of sulfite at carbon ionic liquid electrode: Application
to the analysis of some real samples. Analytica Chimica ...
Cited by 186 Related articles All 2 versions Cite
N Maleki, A Safavi, MM Doroodmand - Talanta, 2005 - Elsevier
A hydride generation method for the determination of traces of selenium at ngmL− 1
concentration ranges has been introduced using a solid mixture of tartaric acid and sodium
tetrahydroborate. Atomic absorption spectrometry (AAS) has been used as the detection ...
Cited by 36 Related articles All 4 versions Cite
Phase behavior and characterization of ionic liquids based microemulsions
A Safavi, N Maleki, F Farjami - Colloids and Surfaces A: Physicochemical …, 2010 - Elsevier
A microemulsion based on imidazolium ionic liquids (ILs), 1-octyl-3-methylimidazolium
chloride [omim][Cl], as a surfactant, a hydrophobic IL as a substitute for traditional organic
solvent, 1-butyl-3-methylimidazolium hexaflourophosphate [bmim][PF6] and water was ...
Cited by 31 Related articles All 3 versions Cite
N Maleki, A Safavi, Z Ramezani - Journal of Analytical Atomic …, 1999 - pubs.rsc.org
A new method of hydride generation was used for the determination of lead at ng mL− 1
levels by atomic absorption spectrometry (AAS). Lead hydride was generated at 65 C using
solid sodium borohydride and solid tartaric acid. The limit of detection was 4.5 ng mL− 1 ...
Cited by 25 Related articles All 4 versions Cite
A Safavi, N Maleki, MM Doroodmand - Analytica chimica acta, 2010 - Elsevier
A chromatographic technique is introduced based on single-walled carbon nanotubes
(SWCNTs) as stationary phase for separation of Ar, CO2 and H2 at parts per million (ppm)
levels. The efficiency of SWCNTs was compared with solid materials such as molecular ...
Cited by 6 Related articles All 4 versions Cite
N Maleki, Z Ramezani, H Kaabi - Analytica chimica acta, 1996 - Elsevier
A solid based titrimetric method is introduced in which a solid titrant is poured to a solution
by a vibrating spatula fixed to the pan of a balance. The spatula, the balance, and the
responses of the detector are measured and controlled by a personal computer. The ...
Cited by 3 Related articles All 4 versions Cite
A Safavi, N Maleki, F Aghakhani Mahyari… - Fullerenes, …, 2013 - Taylor & Francis
Different carbon ionic liquid electrodes were constructed from several kinds of carbon
allotropes such as multi-walled carbon nanotubes, single-walled carbon nanotubes,
graphite, fullerene and carbon nanofiber by using 30wt% of the ionic liquid, n- ...
Cited by 1 Related articles All 2 versions Cite
New cavity design suitable for monitoring gaseous samples by molecular emission cavity analysis
N Maleki, A Safavi, Z Ramezani - Analytica chimica acta, 2000 - Elsevier
A new flame-containing cavity for molecular emission cavity analysis (MECA) was designed.
The reliability of the proposed design was evaluated using SO2 as a representative sulfur-
containing compound. The blue emission of excited S2 was monitored by a ...
Cited by 1 Related articles All 4 versions Cite
Design of a Simple and Stand-alone RS-232c Interface
N Maleki, B Haghighi - Journal of Chemical Education, 1995 - ACS Publications
Textbooks that show static diagrams, whether rendered by computer or human, can sometimes
be difficult to un- derstand and often cannot convey desired information. An example of this is
thep-u-Trelationship in simple one com- ponent systems. Students cannot see that the pT ...