Drylining process are fastest way to construct partitions/ceilings and It's long-lasting material construction.
Where are used; Drylining construction are used in a commercial spaces/European residential projects/Independent Villas.
What can we construct; Party Wall/Internal Partition/Thermal/Sacrificial Lining/Ceilings/Metal Roofs
Party Wall
Party wall are made between apartment/apartment and apartment/communal.
Specification;
Metal; Twin Vertical Studs and Base Track
Deflection;
Plasterboard Strips
Head Track (Deep Channel or Extra Deep Channel)
Gyproc Sealant
Acoustic; 3 Layer Insulation
Lining; 2 Layer plasterboard to each side of party wall
Fire Rating; 90/120/160/190 minute (*according to the design)
Internal Partition Type 1
Internal Partition Type 1 is without insulation wall are made within the apartment or communal corridor area.
Specification;
Metal; 70mm Vertical Studs
Deflection;
Plasterboard Strips
Head Track (Deep Channel or Extra Deep Channel)
Gyproc Sealant
Acoustic; Non-acoustic
Lining; Single Layer plasterboard to each side of partition
Fire Rating; 30/60/90 minute (*according to the design)
Internal Partition Type 2
Internal Partition Type 2 is with insulation wall are made within the apartment or communal corridor area.
Specification;
Metal; 70mm Vertical Studs
Deflection;
Plasterboard Strips
Head Track (Deep Channel or Extra Deep Channel)
Gyproc Sealant
Acoustic; Infill Insulation
Lining; Single Layer plasterboard to each side of partition
Fire Rating; 30/60/90 minute (*according to the design)
Thermal Lining/Sacrificial Lining
Thermal lining is made where there are staircase/lift/shaft-risers on the other side of the apartment. They provide sound & fire proofing to accommodation sides.
Specification;
Metal; Vertical I Studs
Deflection; N/A
Acoustic; Infill Insulations
Lining; Single Layer plasterboard to one side of partition
Fire Rating; 60/90/120 minute (*according to the design)
Shaft/Riser Wall
Shaft/riser wall are located in the communal corridors. They highly fire rated wall to provide extreme level fireproofing.
Specification;
Metal; 70mm Vertical Studs
Deflection;
Plasterboard Strips (2 or 1 Layer)
Head Track (Deep Channel or Extra Deep Channel)
Gyproc Sealant
Acoustic; Infill Insulation
Lining; Single Layer plasterboard to each side of partition
Fire Rating; 60/90/120 minute (*according to the design)