Formula (from Water System Guide's sizing method):
daily hardness load (grains/day) = hardness (gpg) × softened gallons per day
required working grains = daily hardness load × (service days + reserve days)
If your result is in mg/L or ppm as calcium carbonate, divide by 17.118 to get grains per gallon.
Worked example (every value labeled):
Input | Value | What it is
Hardness — 10 gpg — hypothetical measured input
Softened use — 300 gal/day — Penn State example convention, 75 gal/person/day × 4 people
Window — 7 service + 1 reserve = 8 days — chosen example assumption
Daily load — 3,000 grains/day — 10 × 300
Target — 24,000 working grains — 3,000 × 8
The result is a minimum usable working capacity, not a nominal marketing size. Compare it with the exact model's documented capacity at the proposed salt dose. Iron and manganese call for a review, not an invented compensation factor.
Make your own copy of this worksheet
Next: run it in the water softener sizing calculator, read what a grain capacity rating means, or see the full sizing method with more examples.
Published by Water System Guide, an independent water treatment research publisher (not a manufacturer, dealer, installer, utility or laboratory). Statistics are quoted from the open dataset doi.org/10.5281/zenodo.23534609 (CC BY 4.0). Cite the original source for any single figure.
More from Water System Guide: Hard water data · Planning worksheets · Salt, chloride and local rules · watersystemguide.com