Daily gallons decide capacity. Gallons per minute decide whether the system keeps up when several fixtures run at once. Whole-house equipment has to pass both.
List what could reasonably run together, then add the flows.
Fixture | Starting value | Basis
Shower — 2.0 gpm — EPA WaterSense maximum for labeled showerheads
Bathroom faucet — 1.5 gpm — EPA WaterSense maximum for labeled bathroom faucets
Kitchen faucet — 2.2 gpm — federal maximum
Replace any starting value with the fixture label or a measured flow. A static pressure reading or the meter's pipe size is not a flow measurement. Compare the total with the exact model's documented rated service flow, not a "maximum flow" label, and check its pressure drop at that flow.
Next: run the whole-house flow-rate calculator or read how to size a whole-house filter.
Published by Water System Guide, an independent water treatment research publisher (not a manufacturer, dealer, installer, utility or laboratory). Statistics are quoted from the open dataset doi.org/10.5281/zenodo.23534609 (CC BY 4.0). Cite the original source for any single figure.