26 Ga bare Copper wire
30 Ga bare Copper wire
Nylon 6,6 Polymer wire
Step 1:
Take a 26 Ga bare copper wire of lenght 0.9 meters and create a loop on both ends.
Step 2:
Hook both the ends to motors as shown in figure to motor E0 and E1.
Step 3:
Now take the 30 Ga bare copper wire and cut it at 3.6 meters and create loops on both ends.
Step 4:
Now hook one end of the wire to the motor E0 and run the wire along the pulley with weight and connect it to motor Z
Step 5:
Now press the button 3 (Mandrel only) and coil the 30 Ga wire around the 26 Ga as shown.
Step 6:
Next run the 30 Ga wire through the follower guide as shown and press button 2(Coil around mandrel).
Step 7:
Wait till the traveller plate reaches the minimum point and then move the follower guide out of the way and press mandrel only button and coil the wire around the mandrel.
Step 8:
Remove the wires from the top motor and take a 3.6 m Nylon 6,6 tread and create loops on both ends.
Step 9:
Now hook one end of the thread to the motor E0 and run the wire along the pulley with weight and connect it to motor Z
Step 10:
Press the button 1(Twisting) which will help with the twisting of the thread.
Step 11:
Now add the copper wires to the top motor and press the button __(Mandrel only) and coil the thread around the copper wires.
Step 12:
Next run the thread through the follower guide as shown and press button __(Coil around mandrel).
Step 13:
Remove the entire setup from the machine and anneal the setup at 195K for 45 mins
Step 14:
Now make a small cut on the coiled 30 Ga wire and again fix the setup to the E0 motor and E1 motor.
Step 15:
Hold the cut 30 Ga wire and press the button 3 ( Mandrel only) so that the wire will be uncoiled.
Step 16:
Now cut the wire with coiled thread into your desired length. Hold the 26 Ga wire with a plyer and pull it out.