Corrosion Damage Assessment of Prestressed Concrete Structures

Selected publications:

  • Dubuc, B., Ebrahimkhanlou, A., Salamone, S., (2017). “Higher order longitudinal guided wave modes in axially stressed seven-wire strands”, Ultrasonics, Vol. 84, pp.382-391.
  • Ercolino M., Farhidzadeh, A., Salamone, S., Magliulo, G., (2015). “Detection of onset of failure in prestressed strands by cluster analysis of acoustic emissions”, Structural Monitoring and Maintenance: an international journal, Vol.2 (4).
  • Farhidzadeh, A., Salamone, S., (2015). “Reference-free corrosion damage diagnosis in steel strands using guided ultrasonic waves”, Ultrasonics, Vol. 57(3), pp.198-208.