The same device used for the electrospray may exhibit varicose instability. In this case, the jet undergoes lateral displacement following a conical helix or even a chaotic trajectory. We have modelled this phenomena using the fluid mechanical counterpart of the Cosserat rod model and accounting for the electrostatic forces. For more details, visit our publications in the electro-coflow configuration or the stagnant gas configuration.