Storage Navigator or Element Manager is a webserver that allows you to perform day-to-day activities on a VSP. You will hear the terms Storage Navigator and Storage Navigator 2. The difference is that Storage Navigator is the software that comes with enterprise class arrays (VSP, USP, etc) while Storage Navigator 2 is the software that comes with modular class arrays (HUS,etc). Hitachi Storage Navigator provides a unified GUI for managing and optimizing the VSP storage system. You access the system in Storage Navigator from any computer with a web browser. Besides the GUI, Storage Navigator provides a CLI to allow scheduling of storage system events.

To access the GUI you open your browser and point it to the ip of the SVP (storage processor - black box that comes with your array in the cabinet) given by you by the HDS technician. The second way to open it is to use HCS (hicommand suite) and right click on the array and select Element Manager. There is no difference between the terms element manager and storage navigator from a admin perspective, those terms are synonyms.


Hitachi Device Manager Storage Navigator Download


Download Zip 🔥 https://shurll.com/2yGaxG 🔥



Starting with VSP Hitachi decided to port things from the old Java interface into a newer more modern looking interface using Flash. That being said, there are still portions of the SVP that will launch a Java applet on the VSP as well. The USP class arrays are using the Java applet entirely

Specific levels of microcode will have a bug where apache will not respond properly and need to be reopen. If you see the message bellow, just close your window and reopen it again by clicking on Element Manager once more. You should be ok the second time.

You should see the Hitachi Storage Navigator screen. Please note that this is a tool totally outside Hitachi Command Suite, and much closer to the array. In fact, a lot of operations (changing a port for example, cannot be done from HCS, only from SVP).

Remember that HCS is actually an application that holds it's own database regarding hosts, what they see, what type they are and where they are allocated. However, Strorage Navigator sits more closely to the hardware and admins have the option to perform activities using Storage Navigator as well as Device Manager. The trouble with that is that any changes that are being performed in SN they are not "pushed" into device manager (hitachi command suite).

As a result, storage admins should Refresh the storage arrays defined under the Command Suite before performing any tasks especially if they believe that someone else might be touching Storage Navigator as well. The refresh operation is nothing more then a pull where HCS will read the config from the Storage Navigator and correct any missing information in it's own database. A

The refresh is pretty simple, after you login to HCS you need to expand your arrays under All Storage Systems, then Click on the array you want to refresh and wait for the screen to load. Once summary is loaded on the right pane you right click the storage name and select "Refresh Storage System".


If you want to check the task status at a later time, just click on the Administration tab at the top, then select Data Collections Tasks and you should see your refreshs task in there. Once done your HCS should be in line with Storage Navigator.