Three-phase pad-mounted compartmental type distribution transformers are designed for indoor or outdoor locations. Unobtrusive construction allows them to be installed in locations exposed to public view like schools, shopping centers and industrial sites. A wide array of configurations and accessories are available to meet a broad range of application demands.
Standard Ratings
45, 75, 112.5, 150, 225, 300, 500, 750, 1000, 1500, 2000 & 2500 KVA ( Above 2500 KVA as erquired)
Standard High-voltage & insulation level (BIL)
13200 V BIL: 95KV
13800 V BIL: 95KV
14400 V BIL: 95KV
23900GrdY/13800 V BIL: 125KV
24940GrdY/14400 V BIL: 125KV
34500GrdY/19920 V BIL: 150KV
Standard de-energized before operating tap changer
Two - 2½% taps above and below rated voltage
NEMA taps (14400, 13800, 13200, 12470, 12540 V)
Standard secondary voltage & insulation level (BIL)
The basic insulation level (BIL) of the secondary voltage shall be 30 kV.
208Y/120 V
230Y/133 V
400Y/231 V
480Y/277 V
240D/120 MIDTAP
480D
240D
Standard primary and secondary connections
Delta - Wye
Grounded Wye - Wye
Delta - Delta
Standard Impedance Voltage (%)
150KVA~400KVA 3.0% ~ 4.0%
400KVA~750KVA 3.5% ~ 4.5%
750KVA~1500KVA 4.0% ~ 5.5%
1500KVA~2500KVA 5.0% ~ 6.0%
Standard Sound Level (Average) decibels
150KVA~400KVA 55 db
400KVA~750KVA 58 db
750KVA~1500KVA 60 db
1500KVA~2500KVA 62 db
Following is required it shall be clearly stated on the inquiry:
Overcurrent protection by a Bay-O-Net expulsion fuse
Overcurrent protection by a Bay-O-Net expulsion fuse/ with a partial range under-oil ELSP current-limiting fuses
Primary loadbreak dry-well fuse canisters
Provided with an on/off loadbreak switch
4-position Loadbreak Switch / V-Blade Switch / T-Blade Switch
Accessories: Any additional accessories will be specified on the inquiry
Externally operated off- load tap changer
Pressure relief valve
Drain valve with sampler on top and bottom
Liquid level gauge
Oil temperature gauge
Ground pad and clamp with grounding
Stainless Diagrammatic name plate
Jacking Pad.
Other Accessorie
Lifting Lugs (4)
Bolted Cover w/Nut Guard
Cabinet Hinges & Mounting Studs
20” Deep Cabinet (45-1000 kVA)
24” Deep Cabinet (1500-2500 kVA)
30” Deep Cabinet (@34.5/19.92kV)
Low Voltage 6-Hole / 8-Hole Spade / 10-Hole Spade w/Supports
Options make the product non-standard
Low Voltage Spade - 12, 16, 20-Hole
SS Tank Base & Cabinet
Auxiliary Contacts for Liquid Level Gauge
Auxiliary Contacts for Dial Type Thermometer
Auxiliary Contacts for Pressure/Vacuum Gauge