This is M.Tech Mechanical engineering project on "simulation study of cryogenic air separation unit using aspen hysys at Rourkela Steel Plant". As the name suggest the simulation investigation of cryogenic air separation unit (Rourkela steel plant, Odisha) is done by using Aspen Hysys. It is based on steady state and dynamic (high pressure column and low pressure column) both. The dynamic air separation unit has been designed based on PI controller. You can also Subscribe to FINAL YEAR PROJECT'S by Email for more such projects and seminar.
The air separation unit of Rourkela steel plat is simulated using Aspen Hysys software. 2. This model produces purity of Oxygen 98.889%, Nitrogen 99.1513%, Argon 100% and molar flow rate of Nitrogen 3553 kgmole/h, Oxygen 943.1kgmole/h and Argon 16.90 kgmole/h for an inlet Air flow rate of 4521 kgmole/h at pressure of 101.3 kPa and temperature of 280C which is economically suitable for steel plant.