Private wells are tested by their owners, not by a utility. These USGS and EPA figures show why a well test comes before any equipment choice.
The median hardness of 2,160 domestic (private) wells sampled by USGS in 1991–2004 was 162 mg/L as calcium carbonate, which is in USGS's "hard" range. (USGS (DeSimone), 2009; source; row homes-02)
80% of the domestic wells in that USGS sample had hardness between 30.3 and 370 mg/L. (USGS (DeSimone), 2009; source; row homes-03)
A quarter of those domestic wells exceeded 267 mg/L, and a tenth exceeded 370 mg/L (75th and 90th percentiles). (USGS (DeSimone), 2009; source; row homes-04)
USGS found hard and very hard groundwater mainly in western and central aquifers and in carbonate and some sandstone aquifers in the East. (USGS (DeSimone, Mcmahon and Rosen), 2014; source; row homes-05)
Around 15% of the U.S. population, over 43 million people, rely on private wells for drinking water (EPA, updated August 2026). (U.S. EPA, updated 2026-08-25; source; row wells-01)
EPA estimates that more than 23 million households rely on private wells for drinking water. (U.S. EPA, updated 2026-08-25; source; row wells-02)
Private wells are not regulated under the Safe Drinking Water Act (EPA). (U.S. EPA, updated 2026-03-02; source; row wells-03)
About 23% of domestic wells sampled by USGS had at least one contaminant above a human-health benchmark. (USGS (DeSimone), 2009; source; row wells-04)
Radon exceeded the lower proposed MCL (300 pCi/L) in about 65% of sampled domestic wells and the higher proposed MCL (4,000 pCi/L) in about 4%. (USGS (DeSimone), 2009; source; row wells-05)
Nitrate, arsenic, manganese, strontium and gross alpha radioactivity each exceeded health benchmarks in about 5% to 7% of domestic wells. (USGS (DeSimone), 2009; source; row wells-06)
Total coliform bacteria were detected in about 34% of sampled domestic wells and E. coli in about 8%. (USGS (DeSimone), 2009; source; row wells-07)
Iron exceeded EPA's secondary (aesthetic) level in about 19% of domestic wells and manganese in about 21%. (USGS (DeSimone), 2009; source; row wells-08)
About 15% of domestic wells had total dissolved solids above EPA's 500 mg/L secondary level. (USGS (DeSimone), 2009; source; row wells-09)
About 16% of domestic wells had pH outside EPA's recommended 6.5–8.5 range. (USGS (DeSimone), 2009; source; row wells-10)
Nitrate exceeded the MCL more often in agricultural areas than in other land-use settings. (USGS (DeSimone), 2009; source; row wells-11)
USGS and CDC estimate about 2.1 million people may drink private-well water with arsenic above 10 µg/L (2017). (USGS and CDC, 2017-10-18; source; row wells-12)
That arsenic model was built from water samples from more than 20,000 domestic wells. (USGS and CDC, 2017-10-18; source; row wells-13)
One in every five wells sampled in USGS's 1991–2010 principal-aquifer studies had a contaminant at a level of potential human-health concern. (USGS, 2014; source; row wells-14)
Next: compare treatment types in the home water treatment selection guide, or check what a certified filter claim actually covers.
Published by Water System Guide, an independent water treatment research publisher (not a manufacturer, dealer, installer, utility or laboratory). Statistics are quoted from the open dataset doi.org/10.5281/zenodo.23534609 (CC BY 4.0). Cite the original source for any single figure.
More from Water System Guide: Hard water data · Planning worksheets · Salt, chloride and local rules · watersystemguide.com