Project Build

Thank You Professor Ken Arnold for allowing us to use your lab!

MPPT Prototype

MPPT Charge Controller KiCAD Schematics

  • Output of buck and filter circuit
  • Input is a 50 Khz square wave 75% duty cycle at 12 volts
  • DC output to the battery
  • Functioning as intended
  • Output is 8.9 V which is ≅ 75% of 12 V input

Buck converter stepped down input voltage as expected

Inverter Prototype

KiCAD 3D render of PCB to be built

Signal Generated to be fed into Inverter

Inverter output is wrong and unable to troubleshoot further