DESCRIPTION
ThermaCote® is a high-performance thermal barrier that utilizes ceramic technology to prevent heat and cold transfer.
BASIC USES
ThermaCote® is used on walls and ceilings.
Applicable in residential, commercial, and industrial sectors.
Suitable for all types of surfaces, including metal, brick, cement, concrete (including slabs), cladding stone, old adhered paint, plaster and derivatives, wood and derivatives, bituminous, steel roofs, waterproofing membranes, fiber cement tiles, slates, PU foam, rigid PVC, etc.
ThermaCote® is used for industrial protection: silos, containers, cooling cells, insulation, etc.
PROPERTIES
Flexible, semi-thick coating for protection and/or decoration.
High reflectivity: Approved Cool Roof & Cool Wall.
Eligible for Energy Saving Certificates.
New construction or renovation.
Effective for all seasons.
Optimizes insulation performance of buildings, homes, and industrial components.
Improves thermal comfort.
FINISH
Matte - Tintable
FORMAT
19L
USAGE
Interior / Exterior
APPLICATION TOOLS
Airless spray gun only.
TECHNICAL CHARACTERISTICS
Classification:
NF T 36-005: Family 1 - Class 7b2
NF P 84-403: Class D3 e I1
NF EN 1062: European Classification EVWA: G3E4V2W2A1 / G3E5V2W2A1
Binder:
Specific acrylic
Solvent Type:
Water
Odor:
Neutral
Specific Gravity:
0.62 +/-0.05
Solid Content:
54.6% +/-2%
Viscosity:
20-100 Poise
Gloss Level at 60°:
Matte
Appearance:
Semi-thick coating - Smooth
Colors:
White and colors from the French ThermaCote® color chart (Contact us)
Flash Point:
Not classified as flammable
Shelf Life:
12 months in unopened original packaging
Application Tools:
Airless spray only
Dilution:
Ready to use. Do not dilute.
Coverage:
Coverage may vary depending on the substrate and application quality.
Drying Times at 21°C and 60% relative humidity:
Dry: 2h
Recoat: 12 to 24 hours
Weather conditions and application settings may significantly alter drying times.
Thermal Conductivity:
λ = 0.0345 W/mK according to EN 12667:2002
In situ energy consumption measurement:
Energy consumption reduced for air conditioning by 38% according to EU ISO 9869
Energy consumption reduced for heating by 26% according to EU ISO 9869
Thermal Resistance:
R = 1.49m²K/W for 500µm according to EU ISO 9869
R = 1.87m²K/W for 1mm according to EU ISO 9869
Thermal Emissivity:
88% according to ASTM C-1371
Solar Reflectance:
83% according to ASTM C-1549
Solar Reflectance Index (SRI):
104 when new | 100 when aged according to ISO 16474-3:2020 after 4000 hours
Air Permeability:
0.0001 L/s.m² at 75 Pa according to ASTM E-2178
Water Vapor Permeability:
Sd = 1.69m or 3.617 perms exterior to interior
Sd = 0.87m or 6.779 perms interior to exterior
Gross Calorific Value (QPCS):
1.91 MJ/m² according to NF EN ISO 1716
Maintain fire resistance classification ***
Cleaning:
Water. Ideally warm soapy water.
VOC:
EU limit value for this product (cat. A/c): 40g/l (2010). This product contains max. 5.3g/L
Storage:
Store in a dry place between 5°C and 40°C. Keep away from freezing, high temperatures, and direct sunlight (prolonged exposure to direct sunlight can cause "hardening," rendering the product unusable).
CE EN-1504-2
DESCRIPTION
STANDARD
VALUES
Water vapor transmission
EN ISO 7783
Sd=1.0m - CLASS I
Determination and classification of liquid water transmission rate
EN 1062-3
0.011 W
Measurement of adhesive strength by pull-off
EN 1542
1.23 MPa
Thermal cycling without impact from de-icing salt
EN 13687-3
1.11 MPa
CO2 permeability
EN 1062-6
59 m
GOOD PRACTICE APPLICATION
Cover everything that you do not want to paint.
Apply between 10°C and 40°C. The substrate temperature should be between 10°C and 40°C.
Relative humidity should be below 80%.
Ensure that the substrate is at least 3°C above the dew point.
For a slope of less than or equal to 3%, contact us.
Do not apply if rain is expected within the next 24 hours.
SURFACE PREPARATION
Surfaces must be clean, dry, and free of oil, grease, rust, and any other surface contamination.
Remove all loose and flaking material to a solid and sound surface.
Clean the surface with ELIXCLEAN* or SOAPCLEAN*, depending on the level of dirt.
Surfaces with moss, mold, and/or algae should be treated with ATM PRO* or PROXYNET*.
Surfaces with localized damage should be repaired with THERMACOTE ROOF REPAIR TAPE, COSMOFER* or CHOUKROUT*.
Friable or powdery surfaces should be treated with ELIXFOND* or ELIXIMPRESS*.
METALLIC SURFACES
Ferrous:
Remove all signs of corrosion by sand or grit blasting to SIS-Sa 2½.
If blasting is not possible, surfaces should be manually prepared to SIS-St3 and primed with OWATROL PID 60 or OWATROL CIP.
Non-ferrous (Aluminum, Copper, Galvanized, etc.):
Treat with OWATROL OWAPHOS.
DIFFICULT SURFACES
Very old and dirty bituminous coatings.
Areas of temporary water retention on flat roofs, i.e., areas subject to pooling. Prime with PRIMTHERM*.
For all the above scenarios, refer to the THERMACOTE equipment and application guide for additional information.
SPECIFIC SURFACES
These types of surfaces should be coated with an appropriate primer. Contact us for advice. For a slope of less than or equal to 3%, contact us.
APPLICATION
The application of ThermaCote® requires an airless pump capable of maintaining a spray output rate of 8 L/min. Refer to the operating instructions and safety information of your airless pump.
The resulting weight must always be adjusted to the substrate, its relief, and the desired aesthetic.
In case of strong color contrast, an additional coat (ThermaCote or primer*) may be necessary.
Recommended application pressure of 150 to 200 bar. Check the spray quality and adjust the pressure if necessary.
ThermaCote® should be applied in coats of 250µm to 500µm WFT.
The application is done in cross passes. 2 cross passes on smooth or slightly rough surfaces, 4 cross passes on very rough surfaces.
Allow ThermaCote® to dry completely between coats (minimum 12h) when applying multiple coats.
Refer to the THERMACOTE equipment and application guide for additional information or contact us.
RESTRICTIONS
Not suitable for applications in swimming pools, tanks, water tarps, etc., and generally for any work where permanent contact with water is possible.
Cannot be applied over surfaces treated with water repellents, e.g., silicone. When in doubt, contact us. Do not apply over old waterproofing systems (coatings, membranes).
SAFETY
Refer to the safety data sheet (SDS) available on our website www.owatrol.com and the label text. Keep out of reach of children.
*Mismo fabricante. ** BAT-EN-112 / Reflective roof coatings/ For France / CAE for Spain ... *** 2000/553/EC: Commission Decision of 6 September 2000 implementing Council Directive 89/106/EEC as regards the external fire performance of roof coverings (notified under document number C(2000) 2266): Any external covering must have a GCV ≤ 4 MJ/m²).
This technical sheet cancels and replaces any previous technical sheet for the same product. Its purpose is to inform the user about the product. The information contained in this technical sheet is based on our current knowledge. However, the information contained in this document cannot replace a specification appropriate to the nature and conditions of the substrate to be coated. Due to continuous technical advances, it is the user's responsibility to establish that this document has not been replaced by a more recent edition. The information contained