Horner Automation Group designs, builds, and markets a wide array of industrial All-in-One Controllers, consisting of programmable HMI, I/O, software and peripherals for the Industrial, Process Control and Building Automation markets.
MODEL A BUILT-IN I/O: 12 DIGITAL INPUTS, 12 DIGITAL OUTPUTS, 4 ANALOG INPUTS, 2 ANALOG OUTPUTS
MODEL R BUILT-IN I/O: 12 DIGITAL INPUTS, 6 RELAY OUTPUTS, 2 PWM OUTPUTS, 4 ANALOG INPUTS, 2 ANALOG OUTPUTS
HE-E0 - No built-in I/O
HE-E2 - 12 DC in, 6 Relay Out, 4 – 12-bit Analog In
HE-E3 - 12 DC in, 12 DC Out, 2 – 12-bit Analog In
HE-E4 - 24 DC in, 16 DC Out, 2 – 12-bit Analog In
HE-E5 - 12 DC in, 12 DC Out, 2 – 14/16-bit Analog In (mA/V/Tc/mV/RTD), 2 – 12-bit Analog Out
HE-E6 - 12 DC in, 12 DC Out, 6 – 14/17-bit Analog In (mA/V/Tc/mV/RTD), 4 – 12-bit Analog Out
For years, the Horner XL Series has enjoyed a reputation as the most highly functional All-in-one Controller available anywhere. These products are currently trusted with thousands of applications world-wide. The NEW XL Prime Series builds upon that proven reputation – offering new and existing users alike performance upgrades and a highly secure, modern memory architecture. This is accomplished with a new Horner designed System on Module (SOM) – containing a faster CPU, onboard mass storage and 100% non-volatile memory. The only battery is a small coin cell – simply tasked with maintaining the clock.
HE-E0 - No built-in I/O
HE-E2 - 12 DC in, 6 Relay Out, 4 – 12-bit Analog In
HE-E3 - 12 DC in, 12 DC Out, 2 – 12-bit Analog In
HE-E4 - 24 DC in, 16 DC Out, 2 – 12-bit Analog In
HE-E5 - 12 DC in, 12 DC Out, 2 – 14/16-bit Analog In (mA/V/Tc/mV/RTD), 2 – 12-bit Analog Out
HE-E6 - 12 DC in, 12 DC Out, 6 – 14/17-bit Analog In (mA/V/Tc/mV/RTD), 4 – 12-bit Analog Out
Perfect for when just a few I/O points are needed. SmartStix can be used remotely or to expand the I/O capacity of any CsCAN Horner OCS application.
HE559DIM610 - 16 DC Inputs (pos/neg logic) for CsCAN with removable field terminals
HE559DIM710 - 32 DC Inputs (pos/neg logic) for CsCAN with removable field terminals
HE559DQM602 - 16 Relay Outputs (2A) for CsCAN with removable field terminals
HE559DQM606 - 16 DC Outputs (pos logic) 0.5A for CsCAN with removable field terminals
HE559DQM706 - 32 DC Outputs (pos logic) 0.5A for CsCAN with removable field terminals
HE559DIQ816 - 16 DC Inputs (pos/neg logic) plus 16 DC Outputs (pos logic) 0.5A for CsCAN with removable field terminals
HE559ADC970 - 12 Analog Inputs (0-10V, 0 -5V, 0-20mA, and 4-20mA) 16-bit resolution with channel-by-channel input selection
HE559MIX577 - 4 Analog Inputs (+/-10V, +/-20mA) 14-bit resolution + 2 Analog Outputs (+/-10V, +/-20mA) 14-bit resolution. Channel-by-Channel voltage/current selection for all channels. For CsCAN with removable field terminals
HE559MIX977 - 8 Analog Inputs (+/-10V, +/-20mA) 14-bit resolution + 4 Analog Outputs (+/-10V, +/-20mA) 14-bit resolution. Channel-by-Channel voltage/current selection for all channels. For CsCAN with removable field terminals
For CAN based networks requiring high-resolution I/O. Our best analog I/O and simple Digital I/O solution
HE579MIX102 - Isolated Mixed Digital/Analog I/O Module (12/6/4). Twelve Isolated, 12/24V DC Inputs (pos/neg logic). Six Relay Outputs (30VDC, 250Vac, 3A). Four Isolated Analog Inputs (16-bit) supporting 4-20mA and 0-10V
HE579RTD100 - Isolated RTD Input Module, 4 channel. Supports PT100, PT200, PT500, Pt-1000, Ni100, Ni120, and Cu10. 0.1°C or F resolution. 0.1% accuracy, typical
HE579RTD200 - Isolated RTD Input Module, 8 channel. Supports PT100, PT200, PT500, Pt-1000, Ni100, Ni120, and Cu10. 0.1°C or F resolution. 0.1% accuracy, typical
HE579THM100 - Isolated Thermocouple Input Module, 4 channel. Supports J, K, T, E, R, S, C, mV. 0.1°C or F resolution. 0.1% accuracy, typical (varies by type and temperature range)
HE579THM200 - Isolated Thermocouple Input Module, 8 channel. Supports J, K, T, E, R, S, C, mV. 0.1°C or F resolution. 0.1% accuracy, typical (varies by type and temperature range)
HE579MIX577 - 4 Analog Inputs (0-10V, 0 -5V, 0-20mA, 4-20mA) 16-bit resolution + 2 Analog Outputs (0-10V, 0 -5V, 0-20mA, 4-20mA) 14-bit resolution. Channel-by-Channel voltage/current selection for all channels
HE579MIX977 - 8 Analog Inputs (0-10V, 0 -5V, 0-20mA, 4-20mA) 16-bit resolution + 4 Analog Outputs (0-10V, 0 -5V, 0-20mA, 4-20mA) 14-bit resolution. Channel-by-Channel voltage/current selection for all channels
HE579ADC570 - 6 Analog Inputs (0-10V, 0 -5V, 0-20mA, 4-20mA, and 10K Thermistor) 16-bit resolution with channel-by-channel input selection
HE579ADC970 - 12 Analog Inputs (0-10V, 0 -5V, 0-20mA, 4-20mA, and 10K Thermistor) 16-bit resolution with channel-by-channel input selection
HE579DAC107 - 4 Analog Outputs (0-10V, 0 -5V, 0-20mA, 4-20mA) 14-bit resolution. Channel-by-Channel voltage/current selection for all channels
HE579DAC207 - 8 Analog Outputs (0-10V, 0 -5V, 0-20mA, 4-20mA) 14-bit resolution. Channel-by-Channel voltage/current selection for all channels
HE579DIQ880 - Smart Block 8 DC inputs and 8 -3 amp relay outputs
HE579DIQ881 - Smart Block 8 DC inputs and 8 2.5 amp DC outputs
HE579MIX105 - Isolated Mixed Digital/Analog I/O Module (12/12/2/2). Twelve Isolated, 12/24V DC Inputs (pos/neg logic). Twelve 12/24VDC Outputs . Two Analog Inputs (14-bit) supporting 4-20mA, 0-10V, 100mV or (16-bit) PT100 RTD, Thermocouple. Two Analog Outputs (14-bit) 0-10 or 0-20mA
HE579ACM300 - SmartBlock AC Power Monitor (3-phase). Provides complete power measurements, including voltage, current, power, power factor, etc. Direct connect up to 600Vac (voltage), and 0-5A (current) per phase
HE579ACM302 - SmartBlock AC Power Monitor (3-phase) w/ 1000A Rogowski Coils. Provides complete power measurements, including voltage, current, power, power factor, etc. Direct connect up to 600Vac (voltage), and 0-5A (current) per phase
HE569DQM212 - 8 High Current, Socketed Relays. Form C (NO/NC) Mechanical Relays with 7A rating (30VDC, 250Vac). Load connections made with Removable Terminal Strips
HE569DQM212-12 - 8 High Current, Socketed Relays. Form C (NO/NC) Mechanical Relays with 7A rating (30VDC, 250Vac). Load connections made with Removable Terminal Strips. Supports 12V relay coils
HE569DQM204 - 8 High Current, Socketed SSRs (AC). Form A (NO) Solid State Relays with 1A rating (1A, 275Vac). Load connections made with Removable Terminal Strips
HE569DQM205 - 8 High Current, Socketed SSRs (DC). Form A (NO) Solid State Relays with 2A rating (2A, 35VDC). Load connections made with Removable Terminal Strips
SmartRail I/O expands the I/O capacity of OCS All-in-One controllers. SmartRail uses fieldbus technology, and can be installed locally or thousands of meters away.
HE599DIM510 - 8 DC Inputs (24VDC pos/neg logic). For spring-clamp terminals, add HE599TRM010
HE599DIM610 - 16 DC Inputs (24VDC pos/neg logic). For spring-clamp terminals, add HE-599TRM010 & HE599TRM008
HE599DIM610-03 - 16 DC Inputs (12VDC pos/neg logic). For spring-clamp terminals, add HE-599TRM010 & HE599TRM008
HE599DIM710 - 32 DC Inputs (24VDC pos/neg logic). SmartLink Terminal Strip (HE599TRM040) and Expansion Cable (HE599CBL040 - 0.5m or HE599CBL240 - 2.0m)
HE599DIQ512 - 8 DC Inputs (24VDC, pos/neg logic). 8 Relay Outputs (2A). For spring-clamp terminals, add (Qty 2) HE599TRM009
HE599DQM506 - 8 DC Outputs (24VDC, pos logic, 0.5A). For spring-clamp terminals, add HE599TRM010
HE599DQM606 - 16 DC Outputs (24VDC, pos logic, 0.5A). For spring-clamp terminals, add HE599TRM010 & HE599TRM008
HE599DQM706 - 32 DC Outputs (24VDC, pos logic, 0.2A). SmartLink Terminal Strip (HE599TRM040) and Expansion Cable (HE599CBL040 - 0.5m or HE599CBL240 - 2.0m) OR SmartLink Relay Output Strip (HE599RLY037) and Expansion Cable (HE599CBL037 - 0.5m or HE599CBL237 - 2.0m)
HE599DQM502 - 8 Relay Outputs (125VDC or 250Vac), 2A. For spring-clamp terminals, add HE599TRM009
HE599DQM602 - 16 Relay Outputs (125VDC or 250Vac), 2A. For spring-clamp terminals, add (Qty 2) HE599TRM009
HE599DAC101 - 4 channel Analog Outputs, 12-bit. Supports 0-10V. For spring-clamp terminals, add HE599TRM011
HE599DAC106 - 4 channel Analog Outputs, 12-bit. Supports 0-20mA, 4-20mA. For spring-clamp terminals, add HE599TRM011
HE599MIX116 - 2 channel Analog Inputs + 2 channel Analog Outputs. 12-bit resolution, channel-by-channel selectable for 0-20mA, 4-20mA, 0-10V. For spring-clamp terminals, add HE599TRM011
HE599ADC170 - 4 channel Analog Inputs, 12-bit. Selectable channel-by-channel for 0-20mA, 4-20mA, 0-10V. For spring-clamp terminals, add HE599TRM011
HE599RTD100 - 4 channel RTD Inputs, 0.1°C. Supports Pt-100. For spring-clamp terminals, add HE599TRM015
HE599THM100 - 4 channel Thermocouple Inputs, 0.1°C (typical). Supports J, K, T, R. For spring-clamp terminals, add HE599TRM011
Featuring Modbus and a RS485 ½ duplex, SmartMod covers a variety of low cost I/O offerings, such as voltage, current, temperature, and digital.
HE359DIQ512 - 4 DC Inputs (12/24VDC neg logic), 4 Relay Outputs (250vac, 30VDC, 2A max). 2000vac isolation (in-RS485 & in-power)
HE359ADC107 - 4 channel Analog Inputs, Voltage (+/-10VDC) 1mV resolution, 2000vac isolation (ch-RS485 & ch-power)
HE359ADC120 - 4 channel Analog Inputs, Current (4-20mA), 1uA resolution, 2000vac isolation (ch-RS485 & ch-power)
HE359DIM610 - 12 DC Inputs (12/24VDC, neg logic). 2000vac isolation (in-RS485 & in-power)
HE359RTD100 - 4 channel RTD Inputs (Pt-100, Ni-100, Pt-1000, Ni-1000) or Resistance Inputs (0-2000ohm). 0.1 degree Celsius resolution, 2000vac isolation (ch-RS485 & ch-power)
HE359THM100 - 4 channel Thermocouple Inputs (Types J,K,R,S,B,E,T,N) or millivolt inputs (+/-1000mV, max). 0.1 degrees Celsius resolution, 2000vac isolation (ch-RS485 & ch-power)
HE359DAC007 - 2 channel Analog Outputs, selectable between Voltage (0-10VDC) and Current (0-20mA). 1mV or 1uA resolution. 2000vac isolation (ch-RS485 & ch-power)
HE359ADC207 - 8 channel Analog Inputs, Voltage (+/-10VDC) 1mV resolution, 2000vac isolation (ch-RS-485 & ch-power)
HE359ADC220 - 8 channel Analog Inputs, Current (4-20mA), 1uA resolution, 2000vac isolation (ch-RS485 & ch-power)
HE359DAC107 - 4 channel Analog Outputs, selectable between Voltage (0-10VDC) and Current (0-20mA). 1mV or 1uA resolution. 2000vac isolation (ch-RS485 & ch-power)
HE359THM200 - 8 channel Thermocouple Inputs (Types J,K,R,S,B,E,T,N) or millivolt inputs (+/-1000mV, max). 0.1 degrees Celsius resolution, 2000vac isolation (ch-RS485 & ch-power)
HE359DAC201 - 8 channel Analog Outputs, Voltage (0-10VDC) 1mV resolution. 2000vac isolation (ch-RS485 & ch-power)