Programming Pump

Per the manual, the three steps define 8 speeds. If you are familiar with binary math, its a binary counter.

Programming is pretty easy, once I figured out how this needs to work.

Press menu, then when you see the locked configuration page, press < and > at the same time and hold until the page unlocks.

Press > until you see the Remote Control menu, then press + to change to Relay Control instead of Stand Alone.

Save when it asks.

Now you need to set the speeds, but set in the Timer menu, not the Speeds menu.

Timer 1 has to be set to 0 rpm. So, when you select Timer speed 1 per the table above (all relays open), then pump is off

Set the rest of the timers to the speeds you want.

Don't worry about the time for the speeds in the Timer menu, they are ignored by the pump, only the speeds are used when you turn on relay control.

I did the following:

    • Timer 1 0

    • Timer 2 600

    • Timer 3 1200

    • Timer 4 1800

    • Timer 5 2300

    • Timer 6 2750

    • Timer 7 3100

    • Timer 8 3450

    • Timer 1 0

    • Timer 2 600

    • Timer 3 900 300

    • Timer 4 1200 300

    • Timer 5 1600 400

    • Timer 6 2100 500

    • Timer 7 2700 600

    • Timer 8 3450 650

Save, and you're done. Now you should be able to close the relays, and have it go the the speeds you selected.