Instant view multi drugs of abuse urine test are diagnostic tests designed to detect the presence of multiple drugs in a urine sample quickly. These multi drugs of abuse urine tests are easy to use, require no special training, and provide accurate results within 3–5 minutes. They are commonly used for drug screening in various settings, including clinical, workplace, and criminal justice settings.
Features of Multi-drugs of Abuse Screen Tests
Quick results: Results are available in just 5 minutes, making instant-view multi-drug abuse screen test ideal for use in various settings.
Non-invasive: Urine is a non-invasive sample type, making it easy and safe to collect.
High accuracy: 99% accuracy, comparable to laboratory-based tests.
Shelf life: 24 month long shelf life and can be stored easily.
Cost-effective: Multi-drug of Abuse Urine Tests are cost-effective, making them an affordable option for drug testing.
Complete qualifications: CE, FDA 510K and NMPA cleared.
Product name Multi Panel drug Screen Rapid Tests (urine)
Format/Shape Dip Card, Flat Cassette, Cup
Strip size The regular strip is 2.5 mm, 3 mm, 4 mm
Specimen Urine
Time to result within 5 minutes
Service OEM available
Shelf life/validity 24 months
Certifications CLIA/510K, CE, ISO13485, FDA, NMPA Cleared
Storage between 2–30°C
Accuracy over 99%
Packing aluminum foil pouch
Manufacture Prometheus Bio Inc
REGULAR CUTOFF ITEMS DRUG NAME CALIBRATOR CUTOFF
AMP Amphetamine D-Amphetamine 1000 ng/mL
BAR Barbiturates Secobarbital 300 ng/mL
BZO Benzodiazepines Oxazepam 300 ng/mL
BUP Buprenorphine Buprenorphine 10 ng/mL
COC Cocaine Benzoylecgonine 300 ng/mL
EDDP EDDP EDDP 300 ng/mL
THC Marijuana Delta -9- THC-COOH 50 ng/mL
MTD Methadone Methadone 300 ng/mL
mAMP Metamphetamine D-Metamphetamine 1000 ng/mL
MDMA Methylenedioxymethamphetamine MDMA 500 ng/mL
OPI300 Opiates 300 Morphine 300 ng/mL
OPI2000 Opiates 2000 Morphine 2000 ng/mL
OXY Oxycodone Oxycodone 100 ng/mL
PCP Phencyclidine Phencyclidine 25 ng/mL
PPX Propoxyphene Propoxyphene 300 ng/mL
TCA Tricyclic Antidepressants Nortriptyline 1000 ng/mL
SPECIAL CUTOFF ITEMS DRUG NAME CALIBRATOR CUTOFF
AMP500 Amphetamine D-Amphetamine 500 ng/mL
AMP300 Amphetamine D-Amphetamine 300 ng/mL
AMP100 Amphetamine D-Amphetamine 100 ng/mL
BAR Barbiturates Secobarbital 200 ng/mL
BZO200 Benzodiazepines Oxazepam 200 ng/mL
BZO150 Benzodiazepines Oxazepam 150 ng/mL
BZO100 Benzodiazepines Oxazepam 100 ng/mL
BZO50 Benzodiazepines Oxazepam 50 ng/mL
BUP Buprenorphine Buprenorphine 5 ng/mL
COC200 Cocaine Benzoylecgonine 200 ng/mL
COC150 Cocaine Benzoylecgonine 150 ng/mL
COC100 Cocaine Benzoylecgonine 100 ng/mL
COC50 Cocaine Benzoylecgonine 50 ng/mL
COC10 Cocaine Benzoylecgonine 10 ng/mL
THC600 Marijuana Delta-9-THC-COOH 600 ng/mL
THC300 Marijuana Delta-9-THC-COOH 300 ng/mL
THC200 Marijuana Delta-9-THC-COOH 200 ng/mL
THC150 Marijuana Delta-9-THC-COOH 150 ng/mL
THC100 Marijuana Delta-9-THC-COOH 100 ng/mL
THC40 Marijuana Delta-9-THC-COOH 40 ng/mL
THC25 Marijuana Delta-9-THC-COOH 25 ng/mL
THC20 Marijuana Delta-9-THC-COOH 20 ng/mL
THC15 Marijuana Delta-9-THC-COOH 15 ng/mL
THC10 Marijuana Delta-9-THC-COOH 10 ng/mL
THC5 Marijuana Delta-9-THC-COOH 5 ng/mL
MTD500 Methadone Methadone 500 ng/mL
MTD200 Methadone Methadone 200 ng/mL
MTD150 Methadone Methadone 150 ng/mL
MTD50 Methadone Methadone 50 ng/mL
mAMP500 Methamphetamine D-Methamphetamine 500 ng/mL
mAMP300 Methamphetamine D-Methamphetamine 300 ng/mL
mAMP100 Methamphetamine D-Methamphetamine 100 ng/mL
MDMA300 Methylenedioxymethamphetamine MDMA 300 ng/mL
MDMA100 Methylenedioxymethamphetamine MDMA 100 ng/mL
OPI200 Opiate Morphine 200 ng/mL
OPI100 Opiate Morphine 100 ng/mL
OPI50 Opiate Morphine 50 ng/mL
OXY Oxycodone Oxycodone 300 ng/mL
PPX Propoxyphene Propoxyphene 100 ng/mL
TCA Tricyclic Antidepressants Nortriptyline 100 ng/mL
SPECIAL ITEMS DRUG NAME CALIBRATOR CUTOFF
APAP5000 Acetaminophen Acetaminophen 5000 ng/mL
APAP2000 Acetaminophen Acetaminophen 2000 ng/mL
COT Cotinine Cotinine 200 ng/mL
CLZP Klonopin Klonopin 300ng/mL
EDDP EDDP EDDP 300 ng/mL
ETG500 Ethyl Glucuronide Ethyl Glucuronide 500ng/mL
ETG300 Ethyl Glucuronide Ethyl Glucuronide 300ng/mL
FEN300 Fentanyl Fentanyl 300 ng/mL
FEN200 Fentanyl Fentanyl 200 ng/mL
FEN100 Fentanyl Fentanyl 100 ng/mL
FEN200 Fentanyl Fentanyl 20 ng/mL
GBPT2000 Gabapentin Gabapentin 2000 ng/mL
GBPT1000 Gabapentin Gabapentin 1000 ng/mL
KET1000 Ketamine Ketamine 1000 ng/mL
KET300 Ketamine Ketamine 300 ng/mL
KET100 Ketamine Ketamine 100 ng/mL
K2–50 K2 JWH-018/JWH-073 50 ng/mL
K2–25 K2 JWH-018/JWH-073 25 ng/mL
K2–20 K2 JWH-018/JWH-073 20 ng/mL
K3–300 AB-PINACA AB-PINACA 300ng/mL
K3–25 AB-PINACA AB-PINACA 25 ng/mL
K4 UR-144 UR-144 5-Pentanoic acid Metabolite 10 ng/mL
KRA500 Kratom Mitragynine 500 ng/mL
KRA250 Kratom Mitragynine 250 ng/mL
LSD10 Lysergic Acid Diethylamide LSD 10 ng/mL
LSD3 Lysergic Acid Diethylamide LSD 3 ng/mL
MDPV500 Methylenedioxypyrovalerone Methylenedioxypyrovalerone 500 ng/mL
MDPV300 Methylenedioxypyrovalerone Methylenedioxypyrovalerone 300 ng/mL
MQL Methaqualone Methaqualone 300 ng/mL
MTHP Methylphenidate Methylphenidate 300 ng/mL
6-MAM 6-Monoacetylmorphine 6-Monoacetylmorphine 10 ng/mL
TRA300 Tramadol Tramadol 300 ng/mL
TRA200 Tramadol Tramadol 200 ng/mL
TRA100 Tramadol Tramadol 100 ng/mL
ZOLP Zolpidem Zolpidem 10 ng/mL
FAQs Of Urine Drugs of Abuse Screen / Urine Screen for Drugs of Abuse
Q.
How Can I Know If The Product Testing Is Running Well?
A.
As an internal quality control program, a colored line appears in the quality control zone © to indicate that sufficient samples have been added and that the correct operating procedures have been followed.
Q.
Can Exhibiting Visible Precipitates Urine Samples Be Used?
A.
Exhibiting visible precipitates urine samples can affect the test results, so urine specimen exhibiting visible precipitates should be centrifuged, filtered or allowed the precipitates to settle to obtain a clear specimen for testing.
Q.
When A Negative Result Appears, One Colored Line Appears In The Quality Control Zone, And Another Colored Line Appears In The Test Zone. Do The Two Lines Need To Be Of The Same Depth?
A.
They don’t need.to keep the same depth, as long as colored lines can be seen in the test zone (whether lighter, deeper, or equal than the lines in the quality control zone), they should be considered a negative result.
Q.
Can I Read The Results Before The Specified Reading Time?
A.
It is not allowed. Even if a positive result appears early on, it is still necessary to read the result within 5 minutes.
Q.
If The Aluminum Foil Pouch Has Been Opened, Should It Be Tested As Soon As Possible?
A.
Because moisture in the air can affect the functionality of the product, it is recommended to use the product immediately after opening the aluminum foil pouch. Similarly, if the packaging pouch is not tightly sealed or punctured before testing, the product inside should no longer be used.
Q.
What Conditions Should The Test Product Be Stored?
A.
Store test kits in the sealed pouch at 2°C to 30°C. The test kits are stable through the expiration date printed on the sealed pouch. The test kits must remain in the sealed pouch until use. If store at 2°C to 8°C, allow the test kits to reach room temperature (15°C to 28°C) before performing the test. Dot not freeze, do not use beyond the expiration date.
Q.
Why Did I Get A False Positives Results?
A.
1. The sample contains interfering substances, such as direct contact with alum, bleach and alcohol;
2. The cold medicine and anti-inflammatory drugs recently used by the tested person contain a small amount of the tested.
Q.
Why Did I Get A False Negative Results?
A.
1. The Tested object is not suitable for this product, such as, use morphine test product to test the person who has taked methamphetamine;
2. Too long after taking drugs, the tested substance has been metabolized by human body and the concentration is lower than the test line.
As one of point of care testing manufacturers, we can offer sorts of related products for sale, anything you need, please contact us.