Minimize time off the chest. Chest Compression Fraction (CCF) is one of the most important measures during CPR. Any unnecessary pause in compressions can lower your score.
Pay particular attention during transitions between rescuers or roles. During two-rescuer CPR, the transition from ventilation to compressions at the fifth cycle is a common point where delays occur. Anticipate the transition and resume compressions promptly rather than waiting for additional instruction.
Maintaining the correct ratio is essential.
Be careful not to deliver an additional breath simply because the first ventilation was inadequate. Quickly repeating breaths can result in too many or overly frequent ventilations.
When transitioning from adult CPR at 30:2 to two-rescuer infant CPR at 15:2, mentally reset the compression count. The shorter cycle moves quickly, and inadvertently continuing to 17 or 18 compressions can result in an incorrect ratio.
Air leaking around the bridge of the nose can prevent effective ventilation.
If you notice air escaping:
Reposition the mask to improve the seal.
Seat the mask firmly over the bridge of the nose.
Position the lower portion of the mask slightly higher on the chin than you may initially expect.
If appropriate for the equipment being used, adjust the mask cushion to improve the fit. Think seal first, then ventilate. Repeatedly delivering breaths without correcting a poor seal will not solve the underlying problem.
The ARC Brayden manikin has a built-in feature that can help you achieve the proper 42 degree head-tilt position for effective ventilations.
The manikin is designed to replicate the head and neck positioning needed to open the airway. As you extend the head, continue until you feel the occiput of the manikin’s head make firm, plastic-to-plastic contact with the neck stop.
If you have not reached that contact point, you have not fully extended the manikin’s head into the intended ventilation position.
Think of that contact as your “cheat code”: when you feel it, you know you have reached the manikin’s designed head-tilt position. From there, focus on maintaining the position, establishing a good mask seal, and delivering your ventilation.
Pay attention to what the scoring system displays after your attempt.
-- / double dash: This indicates that no score was generated. An incorrect compression-to-ventilation ratio is one possible cause, so review your sequence and ratio carefully.
Low or failing numerical score: Review the feedback provided by the system. It can help identify the specific performance element that needs correction before your next attempt.
Consistency matters more than rushing. Know your ratio, anticipate transitions, minimize interruptions in compressions, and establish a good mask seal before ventilating.
Small corrections in technique can make a significant difference.