Search this site
Embedded Files

Download Free IEC 60870-5 104 Protocol Server client Simulator Windows Linux C C++ Programming Test tool

Download Free simulator
IEC 104 Protocol
  • IEC 60870-5-104 Protocol
  • IEC 104 Protocol Source Code Library
  • IEC 104 Linux SDK C C++ POSIX Arm
  • IEC 104 Client Simulator
  • IEC 104 Server Simulator
  • IEC 104 Windows SDK C C++ C# .NET
IEC 104 Protocol
  • IEC 60870-5-104 Protocol
  • IEC 104 Protocol Source Code Library
  • IEC 104 Linux SDK C C++ POSIX Arm
  • IEC 104 Client Simulator
  • IEC 104 Server Simulator
  • IEC 104 Windows SDK C C++ C# .NET
  • More
    • IEC 60870-5-104 Protocol
    • IEC 104 Protocol Source Code Library
    • IEC 104 Linux SDK C C++ POSIX Arm
    • IEC 104 Client Simulator
    • IEC 104 Server Simulator
    • IEC 104 Windows SDK C C++ C# .NET

IEC 60870-5-104 Protocol Source Code Library (SCL) Stack

Windows (C, C++, C# .net), Linux (Arm, POSIX C, C++)

The most complete implementation of IEC 104 protocol stack including File transfer (Monitor and Control Direction), Directory Commnads, Supports all type of Monitoring, command , parameter ASDUs.

Low memory footprint, easy start on any hardware platform, can operate with or without an operating system, delivered as a source code,

high configurability allows to use required features only, royalty-free licensing.


Salient Features


  • Written in ANSI-Standard C Source Code, under a strict corporate coding standard, and supports C++, C#

  • Can be used with or without a Real Time Operating System (RTOS).

  • Transparent licensing scheme - No hidden costs, No deferred payments.

  • High performance, robust and scalable architecture

  • Provides a simple method for systems Integrators and OEMs to utilize standard tools to implement their systems

  • Our stacks are fully compliant with "POSIX" and tested in ubuntu, feroda, Debian, QNX, Linux Embedded OS and Various Cross compiler tool chains.
    Our all protocol stack supports "POSIX compliant operating system"

  • Context-based event-driven model

  • Multiple Server and Client Simulation

  • In a Single Server(link) simulate Multiple Stations (Common Address)

  • Supports Background Scan, Cyclic Data Transmission, Double Transmission, Redundancy and File transfer.

  • Communication with redundant control systems and interruption-free switch over between redundant systems

  • Supports "Select-Before-Operate" and "Direct-Execute" command execution modes

  • In IEC 60870-5-104 Client Side, Data Mode and Test mode connection type available.

  • Source Code Library allows a fast and cost efficient implementation

  • APIs are designed to be very easy to use and flexible


Application Examples

  • Integrate existing devices to a modern control system with a field proven product

  • Use the IEC-104 event based communication instead of polling

  • Feeder automation

  • Substation automation

  • Utility automation

  • Reclosers

  • Protection relays


​Standard IEC 60870-5-104 data types ASDU - Typeids


Type Dec Description


M_SP_NA_1 1 Single-point information

M_SP_TA_1 2 Single-point information with time tag ( IEC 101 Supported )

M_DP_NA_1 3 Double-point information

M_DP_TA_1 4 Double-point information with time tag ( IEC 101 Supported )

M_ST_NA_1 5 Step position information

M_ST_TA_1 6 Step position information with time tag ( IEC 101 Supported )

M_BO_NA_1 7 Bitstring of 32 bit

M_BO_TA_1 8 Bitstring of 32 bit with time tag ( IEC 101 Supported )

M_ME_NA_1 9 Measured value, normalised value

M_ME_TA_1 10 Measured value, normalized value with time tag ( IEC 101 Supported )

M_ME_NB_1 11 Measured value, scaled value

M_ME_TB_1 12 Measured value, scaled value wit time tag ( IEC 101 Supported )

M_ME_NC_1 13 Measured value, short floating point number

M_ME_TC_1 14 Measured value, short floating point number with time tag ( IEC 101 Supported )

M_IT_NA_1 15 Integrated totals

M_IT_TA_1 16 Integrated totals with time tag ( IEC 101 Supported )

M_EP_TA_1 17 Event of protection equipment with time tag

M_EP_TB_1 18 Packed start events of protection equipment with time tag

M_EP_TC_1 19 Packed output circuit information of protection equipment with time tag

M_PS_NA_1 20 Packed single point information with status change detection

M_ME_ND_1 21 Measured value, normalized value without quality descriptor

ASDU_TYPE_22..29 22..29 Reserved (standard area)

M_SP_TB_1 30 Single-point information with time tag CP56Time2a

M_DP_TB_1 31 Double-point information with time tag CP56Time2a

M_ST_TB_1 32 Step position information with time tag CP56Time2a

M_BO_TB_1 33 Bitstring of 32 bit with time tag CP56Time2a

M_ME_TD_1 34 Measured value, normalised value with time tag CP56Time2a

M_ME_TE_1 35 Measured value, scaled value with time tag CP56Time2a

M_ME_TF_1 36 Measured value, short floating point number with time tag CP56Time2a

M_IT_TB_1 37 Integrated totals with time tag CP56Time2a

M_EP_TD_1 38 Event of protection equipment with time tag CP56Time2a

M_EP_TE_1 39 Packed start events of protection equipment with time tag CP56Time2a

M_EP_TF_1 40 Packed output circuit information of protection equipment with time tag CP56Time2a

ASDU_TYPE_41..44 41..44 Reserved (standard area)

C_SC_NA_1 45 Single command

C_DC_NA_1 46 Double command

C_RC_NA_1 47 Regulating step command

C_SE_NA_1 48 Set-point Command, normalized value

C_SE_NB_1 49 Set-point Command, scaled value

C_SE_NC_1 50 Set-point Command, short floating point number

C_BO_NA_1 51 Bitstring 32 bit command

ASDU_TYPE_52..57 52..57 Reserved (standard area)

C_SC_TA_1 58 Single command with time tag CP56Time2a

C_DC_TA_1 59 Double command with time tag CP56Time2a

C_RC_TA_1 60 Regulating step command with time tag CP56Time2a

C_SE_TA_1 61 Measured value, normalised value command with time tag CP56Time2a

C_SE_TB_1 62 Measured value, scaled value command with time tag CP56Time2a

C_SE_TC_1 63 Measured value, short floating point number command with time tag CP56Time2a

C_BO_TA_1 64 Bitstring of 32 bit command with time tag CP56Time2a

ASDU_TYPE_65..69 65..69 Reserved (standard area)

M_EI_NA_1 70 End of Initialization

ASDU_TYPE_71..99 71..99 Reserved (standard area)

C_IC_NA_1 100 Interrogation command

C_CI_NA_1 101 Counter interrogation command

C_RD_NA_1 102 Read command

C_CS_NA_1 103 Clock synchronization command

C_TS_NA_1 104 Test command

C_RP_NA_1 105 Reset process command

C_CD_NA_1 106 Delay acquisition command

C_TS_TA_1 107 Test command with time tag CP56Time2a

ASDU_TYPE_108..109 108..109 Reserved (standard area)

P_ME_NA_1 110 Parameter of measured values, normalized value

P_ME_NB_1 111 Parameter of measured values, scaled value

P_ME_NC_1 112 Parameter of measured values, short floating point number

P_AC_NA_1 113 Parameter activation

ASDU_TYPE_114..119 114..119 Reserved (standard area)

F_FR_NA_1 120 File ready

F_SR_NA_1 121 Section ready

F_SC_NA_1 122 Call directory, select file, call file, call section

F_LS_NA_1 123 Last section, last segment

F_FA_NA_1 124 ACK file, ACK section

F_SG_NA_1 125 Segment

F_DR_TA_1 126 Directory

ASDU_TYPE_127..255 127..255 Reserved (user area)


Knowledge Base

Interoperability


IEC 60870-5-104 Protocol RTU IED Server Interoperability


IEC 60870-5-104 Protocol Master HMI SCADA Client Interoperability

Licensing


Source Code License model:

In this License model, We deliver complete source code of the protocol implementation according to the customer specified operating system(Windows, Linux, QNX...).

Customer may embed the library into unlimited copies of Multiple end-use products for worldwide manufacturing, branding and distribution. Original equipment manufacturers choose this model. They usually have multiple products in their pipeline.


Compiled Library License model:

In this License model, We deliver Dynamic/ Static compiled library (dll / lib) of the protocol implementation according to the customer specified operating system(Windows, Linux, QNX...).

Customer may embed the library into unlimited copies of Multiple end-use products for worldwide manufacturing, branding and distribution. Original equipment manufacturers choose this model. They usually have multiple products in their pipeline.


You can also try our IEC 60870-5-104 Protocol RTU IED Server Simulator, IEC 104 Protocol Master HMI SCADA Client Simulator, IEC 60870-5-104 Protocol Windows SDK c,c++, c# .net and IEC 60870-5-104 Protocol ARM Linux POSIX RTOS SDK

For more details, Contact Us : Contact



Get free Demo IEC 104 Protoccol


IEC 104 Protocol Video Tutorial




Download Evaluation Kit - IEC 104 Development Bundle

New updated Version of IEC 104 Simulator & SDK (Software Development Kit) is available now.

In the Development Bundle, We included IEC 104 Server & Client Simulator, Windows and Linux SDK, C# projects, Doxygen documentation and Raspberry Pi, BeagleBone Demo library.



FacebookLinkedInYouTubeTwitterLinkPinterestTumblrLinkLinkGitHub
Google Sites
Report abuse
Page details
Page updated
Google Sites
Report abuse