Construisez un laser à air à 10 € !
(Price doesn't include high voltage PSU)
We describe a very simple laser: no special gas, no chemical products, no vacuum and no glass work!
This Nitrogen laser uses normal air at atmospheric pressure. All you need is some metal parts and an about 10 kV 1 mA adjustable High tension DC source.
(All dimensions in mm)
(Le prix n'inclut pas le bloc d'alimentation haute tension)
Nous décrivons un laser très simple : pas de gaz spécial, pas de produits chimiques, pas de vide et pas de travail du verre !
Ce laser à azote utilise de l'air normal à pression atmosphérique. Tout ce dont vous avez besoin est de quelques pièces métalliques et d'une source continue haute tension réglable d'environ 10 kV 1 mA.
(Toutes les dimensions en mm)
Brief description:
The whole air laser is based on a rectangular A4 aluminium plate on which is disposed a rectangular A4 plastic sheet (European standard paper A4 dimensions 210 x 297 mm). 2 aluminium plates act as capacitors and 2 other pieces of metal (L) are used as electrodes for plasma channel. 2 U aluminium parts screwed on the main plate can hold all that with Nylon screws.
Nylon screws get electrical insulation and allow user to very easily change, modify or adjust plates, electrodes or plastic film.
A4 plastic film is a low cost very easy to find/repair dielectric solution.
Theory:
In fact, this air laser is a Nitrogen laser which use Nitrogen molecules in air to lase. Ordinary Nitrogen laser uses low pressure wide channel nitrogen like the old very well known "American Scientist" Nitrogen laser project: http://www.montagar.com/~patj/n2lmnu.htm
When a high current electric discharge passes through Nitrogen gas at low pressure, it can generate a coherent radiation at the wavelength of 337.1 nm (UV). The laser action begins when a molecule of Nitrogen absorbs energy by colliding with an electron that moves in the discharge. Molecule becomes in an unstable state and spontaneously falls to a state of lower energy by emitting a photon of radiation at 337.1 nm. The emitted photon may encounter another excited molecule of Nitrogen and merely by its proximity stimulate the molecule to emit an identical photon. The two particles of radiation proceed in the same direction with their waves lockstep. This is the laser action. It will continue as long as the growing pulse encounters more excited molecules of Nitrogen along its path that it does absorbing molecules. In the case of Nitrogen, the molecules on the average linger at a lower level longer that at the upper one before moving on to still lower states. The number of molecules at the lower laser level builds up rapidly, exceeding the number at the upper level and terminating the amplification. In fact, the gas quickly becomes strongly absorbing to 337.1 nm emission. The laser turns off even thought there are still excited molecules left. The turn off time is usually less than 10 ns.
Brève description:
L'ensemble du laser à air repose sur une plaque rectangulaire en aluminium A4 sur laquelle est disposée une feuille rectangulaire en plastique A4 (papier standard européen A4 dimensions 210 x 297 mm). 2 plaques d'aluminium font office de condensateurs et 2 autres pièces de métal (L) servent d'électrodes pour le canal plasma. Des pièces en aluminium 2 U vissées sur la platine principale peuvent maintenir tout ça avec des vis Nylon.
Les vis en nylon constituent une isolation électrique et permettent à l'utilisateur de changer, modifier ou ajuster très facilement des plaques, des électrodes ou un film plastique.
Le film plastique A4 est une solution diélectrique peu coûteuse et très facile à trouver/réparer.
Théorie:
En fait, ce laser à air est un laser à azote qui utilise des molécules d'azote présentes dans l'air pour laser. Le laser à azote ordinaire utilise de l'azote dans un canal large à basse pression, comme l'ancien projet de laser à azote très connu "American Scientist": http://www.montagar.com/~patj/n2lmnu.htm
Lorsqu'une décharge électrique à courant élevé traverse l'azote gazeux à basse pression, elle peut générer un rayonnement cohérent à la longueur d'onde de 337,1 nm (UV). L'action du laser commence lorsqu'une molécule d'azote absorbe de l'énergie en entrant en collision avec un électron qui se déplace dans la décharge. La molécule devient instable et tombe spontanément à un état d’énergie inférieure en émettant un photon de rayonnement à 337,1 nm. Le photon émis peut rencontrer une autre molécule d'azote excitée et simplement par sa proximité stimuler la molécule à émettre un photon identique. Les deux particules de rayonnement avancent dans la même direction avec leurs ondes synchronisées. C'est l'action du laser. Cela continuera tant que l’impulsion croissante rencontrera sur son chemin des molécules d’azote plus excitées que des molécules absorbantes. Dans le cas de l’azote, les molécules moyennes s’attardent plus longtemps à un niveau inférieur qu’au niveau supérieur avant de passer à des états encore plus bas. Le nombre de molécules au niveau laser inférieur s'accumule rapidement, dépassant le nombre au niveau supérieur et mettant fin à l'amplification. En fait, le gaz devient rapidement fortement absorbant jusqu'à l'émission à 337,1 nm. Le laser s’éteint même s’il reste encore des molécules excitées. Le temps d'arrêt est généralement inférieur à 10 ns.
That means that the maximum of energy must arrive in the very first ns. The laser structure must be very fast, avoiding parasitic resistors and mainly parasitic inductance. Using air at normal pressure is more difficult: Oxygen atoms tend to prevent laser emission. Normal pressure means low impedance and low width laser channel. That means that the laser structure must be faster.
Most Nitrogen lasers use Blumlein structure (this one also): 2 high tension capacitors (almost identical), one pole connected to ground and the other pole to an electrode. The 2 electrodes are connected together through a self and charged at a high tension. A spark gap is installed on an electrode: when tension is high enough, an arc occurs: a conductive plasma discharges very quickly one capacitor. One capacitor is about to ground, the other is still at a high potential. The huge tension difference between the 2 electrodes produces a plasma which induce laser beam. Then laser beam turns off, plasma stops and, later, other capacitor is discharged through the self. Then all that is charged again though high tension PSU (Power Supply Unit) and the process start again. That means that the structure must be fast enough to be able to deliver most of the energy in the very first ns: The spark gap capacitor fall time must be very low: parasitic resistors and inductors must be at the minimum.
Calculus:
(Here, we are just looking for orders of magnitude, not precise results)
On this prototype, we can consider that high tension is about 10 kV, each capacitor is about 2 nF (measured), "measured" spark capacitor fall time is about 11 ns, probably a little bit less.
CV=it: i=CV/t: 10 000 x 2 10-9 / 10 10-9 = 2000 A : a 2000 A current sink through spark gap for a few ns !
Total parasitic resistors must induce less than 1 kV to be negligible (compared with 10 kV): U=RI: R=U/I: 5 ohms which is easy to realise: parasitic resistors are not a problem (using copper, aluminium or iron isn't very important)
Total parasitic inductors V=Ldi/dt: L=V/(di/dt): 5 nH which is very little, L=u S n2/ l : S= L l / u n2, l=5 mm, u(air)=4 PI 10-7, n=1, =>20 10-6m2 => 20 mm2 is about 5 x 5 mm
That means that a conductor (spark gap connection for example) 5 mm width and 5 mm length to return to ground has an inductor that is not negligible! Parasitic inductors ARE a problem.
Global Nitrogen structure must be very flat and must keep spark gap connection to ground and capacitor, electrode connection to capacitor parasitic selfs at the minimum: loops area must be minimum.
One says there is a "travelling wave" in the capacitor during discharge. In those little amateur lasers, I don't think so. Anyway, accurately and safely measuring such high-tension very fast phenomena is difficult. You must own a fast oscilloscope and a very fast HT probe or using the ILS low-tension trick or a one turn self safely coupled to the Blumlein self
Cela signifie que le maximum d'énergie doit arriver dans les toutes premiers instants. La structure du laser doit être très rapide, évitant les résistances parasites et principalement l'inductance parasite. Utiliser de l’air à pression normale est plus difficile : les atomes d’oxygène ont tendance à
empêcher l’émission laser. Une pression normale signifie un canal laser à faible impédance et de faible largeur. Cela signifie que la structure laser doit être plus rapide.
La plupart des lasers à azote utilisent une structure Blumlein (celle-ci également) : 2 condensateurs haute tension (presque identiques), un pôle relié à la masse et l'autre pôle à une électrode. Les 2 électrodes sont reliées entre elles par une self et chargées sous haute tension. Un éclateur est installé sur une électrode : lorsque la tension est suffisamment élevée, un arc se produit : un plasma conducteur décharge très rapidement un condensateur. Un condensateur est sur le point d'être mis à la terre, l'autre est toujours à un potentiel élevé. L'énorme différence de tension entre les 2 électrodes produit un plasma qui induit un faisceau laser. Ensuite, le faisceau laser s'éteint, le plasma s'arrête et, plus tard, un autre condensateur se décharge à travers. Ensuite, tout cela est rechargé via un bloc d'alimentation haute tension et le processus recommence. Cela signifie que la structure doit être suffisamment rapide pour pouvoir délivrer l'essentiel de l'énergie dans les toutes premières ns : Le temps de décharge du condensateur de l'éclateur doit être très faible : les résistances et inductances parasites doivent être limitées au minimum.
Calcul:
(Ici, nous recherchons juste des ordres de grandeur, pas des résultats précis)
Sur ce prototype, on peut considérer que la haute tension est d'environ 10 kV, chaque condensateur fait environ 2 nF (mesuré), le temps de décharge du condensateur "mesuré" est d'environ 11 ns, probablement un peu moins.
CV=it : i=CV/t : 10 000 x 2 10-9 / 10 10-9 = 2000 A : un courant de 2000 A passe à travers l'éclateur pendant quelques ns !
Les résistances parasites totales doivent induire moins de 1 kV pour être négligeables (par rapport à 10 kV) : U=RI : R=U/I : 5 ohms ce qui est facile à réaliser : les résistances parasites ne posent pas de problème (en utilisant du cuivre, de l'aluminium ou du fer ce n'est pas très important)
Inducteurs parasites totaux V=Ldi/dt : L=V/(di/dt) : 5 nH ce qui est très peu, L=u S n2/ l : S= L l / u n2, l=5 mm, u(air )=4 PI 10-7, n=1, =>20 10-6m2 => 20 mm2 soit environ 5 x 5 mm
Cela veut dire qu'un conducteur (connexion éclateur par exemple) de 5 mm de largeur et 5 mm de longueur pour retourner à la masse possède une inductance qui n'est pas négligeable ! Les inducteurs parasites SONT un problème.
La structure globale du laser doit être très plate et doit maintenir au minimum la connexion de l'éclateur à la masse et au condensateur, la connexion des électrodes aux selfs parasites du condensateur : la surface des boucles doit être minimale.
On dit qu'il y a une "onde progressive" dans le condensateur pendant la décharge. Dans ces petits lasers amateurs, je ne pense pas. Quoi qu’il en soit, il est difficile de mesurer avec précision et en toute sécurité des phénomènes aussi rapides et à haute tension. Vous devez posséder un oscilloscope rapide et une sonde HT très rapide ou utiliser l'astuce basse tension ILS ou une self à un tour couplé en toute sécurité à la self de Blumlein.
Structure:
We choose a structure simple to build, with very low parasitic inductor, easy to change and adjust: changing the plastic film, a capacitor plate, electrode or adjusting electrode distance is very easy. We use an A4 (210 x 297 mm European standard) main aluminium plate on which we dispose an A4 plastic film, and the 2 capacitor plates. We also install 2 U aluminium rules with nylon screws to press capacitors and electrodes that are L aluminium rules. The 2 electrodes are attached with 2 pull springs that act also as self. 2 nylon screws set distance.
To adjust electrodes distance, simply unscrew a little bit 2 U rules corresponding nylon screws, then adjust distance with the 2 horizontal screws. Once distance OK, screw again the 2 U rules corresponding screws.
A hole in each U rule allows laser to output on one side and to install a 3 screws + springs adjustable mirror on the other side.
Even if this project seems very simple, dimensions has been optimised: I recommend to build the project "as this" before trying to modify parameters.
Bill of material:
- One 210 x 297 aluminium plate (1.5, 2 or 2.5 mm thick)
- One 210 x 297 A4 plastic film (those for printer slide)
- Two 135 x 190 aluminium plates (1.5, 2 or 2.5 mm thick)
- Two 20 x 20 x 250 U aluminium extruded rules
- Two 10 x 20 x 250 L aluminium extruded rules
- Twelve M5 x 20 (or 25 or 30) Nylon screws (or M4 x 20)
- Four metal M3 x 10 screws (chamfered head) with corresponding nuts
- Some M3 metal screws and springs (4 push springs and 2 pull springs)
- Four rubber feet
- One Red + one Black ordinary connectors
- Some 1 Mohms 1W resistors (depending from PSU)
Picture: (CD is just for the scale, these temporary M3 plastic screws are not strong enough)
Structure:
Nous choisissons une structure simple à construire, avec une inductance parasite très faible, facile à changer et à régler : changer le film plastique, une plaque de condensateur, l'électrode ou régler la distance des électrodes est très simple. Nous utilisons une plaque principale en aluminium A4 (210 x 297 mm norme européenne) sur laquelle nous disposons un film plastique A4, ainsi que les 2 plaques du condensateur. Nous installons également des règles en aluminium en U avec des vis en nylon pour presser les condensateurs et les électrodes qui sont des règles en aluminium en L. Les 2 électrodes sont fixées à l'aide de 2 ressorts de traction qui font également office de selfs. 2 vis en nylon règlent la distance.
Pour régler la distance des électrodes, il suffit de dévisser un peu les 2 vis nylon correspondantes des règles en U, puis de régler la distance avec les 2 vis horizontales. Une fois la distance OK, revissez les 2 vis correspondantes des règles U.
Un trou dans chaque règle en U permet de sortir le laser d'un côté et d'installer un miroir réglable 3 vis + ressorts de l'autre côté.
Même si ce projet semble très simple, les dimensions ont été optimisées : je recommande de construire le projet "tel quel" avant de tenter de modifier les paramètres.
Nomenclature:
- Une plaque aluminium 210 x 297 (épaisseur 1,5, 2 ou 2,5 mm)
- Un film plastique A4 210 x 297 (ceux pour imprimante)
- Deux plaques d'aluminium 135 x 190 (épaisseur 1,5, 2 ou 2,5 mm)
- Deux règles en aluminium extrudé 20 x 20 x 250 U
- Deux règles en aluminium extrudé de 10 x 20 x 250 L
- Douze vis Nylon M5 x 20 (ou 25 ou 30) (ou M4 x 20)
- Quatre vis métalliques M3 x 10 (tête chanfreinée) avec écrous correspondants
- Quelques vis et ressorts métalliques M3 (4 ressorts de poussée et 2 ressorts de traction)
- Quatre pieds en caoutchouc
- Un connecteur ordinaire Rouge + un Noir
- Quelques résistances 1 Mohms 1W (selon le bloc d'alimentation)
Photo : (Le CD est juste pour l'échelle, ces vis en plastique M3 temporaires ne sont pas assez solides)
Construction: (timing is for best understood, not for best efficiency ;-)
- Drill 4 holes d = 3.2 in the main 210 x 297 plate: 2 along one 297 side, 2 along the other 297 side at 10 from side, chamfer it for chamfered screws (screw heads must disappear in the plate to avoid disturb plastic sheet)
- Drill 2 holes d = 3.2 in each U rule and attach U rules on the big side of the main plate with the 4 rubber feet
- Drill 1 hole d = 10 in the middle (vertical face) of each U rule for laser outputs
- Drill 8 holes d = 4.0 on the upper side of each U rule and screw it for M5 screw
- Dispose the A4: 210 x 297 plastic film on the main plate
- Round (r = 5) the two 135 x 190 other plates corners and install it on main plate at 10 from all borders
- Dispose the 2 10 x 20 L rules on the plates in a symmetrical way: ( |__ __| ). Distance: 1 mm
- Install 8 M5 x 20 Nylon screws in each U rule and screw it to press plates and L electrodes
- Chamfer L rules side at 10 to increase distance between L rule and U rule at minimum 10 mm
- In a U rule, drill a 2.3 hole and screw it for M3, install a M3 x 20 screw with a push spring: that's the spark gap. Set it at 5 mm
- In a U rule, drill two d = 6.0 holes, install the Black connector without insulation: the ground connection
- Drill 4 d = 4.0 holes and 1 d = 6.0 in one electrode (and screw 2 holes at M5) and 3 d = 6.0 in the other.
- Install 2 pull springs, 2 M5 x 20 plastic screws and 1 Red connector on electrodes (Nota: pull springs act also as electrical self)
- Connect 5 x R 1 Mohm 1 W resistors between Red connector and electrode (in a clear plastic tube)
-You can also add three M3 holes in a U rules around one hole output and install a little plate with a glued mirror and 3 M3 x 10 screws and 3 push springs. Adjust screws to align mirror optical axis and plasma channel (with you eye or a little red laser pointer)
Nota: How to align mirror: take a white paper sheet, make a 1 mm hole in the middle. Disconnect and discharge laser. Look through the paper hole to the mirror through the laser output hole. Align your eye with electrodes and adjust mirror screws until paper hole is just centred between the 2 electrodes.
Construction : (l'ordre est destiné à une meilleure compréhension, pas à une meilleure efficacité ;-)
- Percer 4 trous d = 3,2 dans la plaque principale 210 x 297 : 2 le long d'un côté 297, 2 le long de l'autre côté 297 à 10 du côté, chanfreiner pour les vis chanfreinées (les têtes de vis doivent disparaître dans la plaque pour ne pas déranger la feuille plastique )
- Percez 2 trous d = 3,2 dans chaque règle en U et fixez les règles en U sur le grand côté de la platine principale avec les 4 pieds en caoutchouc
- Percer 1 trou d = 10 au milieu (face verticale) de chaque règle U pour les sorties laser
- Percez 8 trous d = 4,0 sur la face supérieure de chaque règle en U et vissez-la pour vis M5
- Disposer le film plastique A4 : 210 x 297 sur le plateau principal
- Arrondir (r = 5) les deux autres coins de la plaque 135 x 190 et l'installer sur la plaque principale à 10 de toutes les bordures
- Disposer les 2 règles de 10 x 20 L sur les plaques de manière symétrique : ( |__ __| ). Distance : 1 mm
- Installez 8 vis en nylon M5 x 20 dans chaque règle en U et vissez-la aux plaques de pression et aux électrodes en L.
- Chanfreiner le côté des règles L à 10 pour augmenter la distance entre la règle L et la règle U au minimum 10 mm
- Dans une règle en U, percez un trou de 2,3 et vissez-le pour M3, installez une vis M3 x 20 avec un ressort de poussée : c'est l'éclateur. Réglez-le sur 5 mm
- Dans une règle en U, percez deux trous d = 6,0, installez le connecteur Noir sans isolant : la liaison à la terre
- Percer 4 d = 4,0 trous et 1 d = 6,0 dans une électrode (et visser 2 trous en M5) et 3 d = 6,0 dans l'autre.
- Installez 2 ressorts de traction, 2 vis plastique M5 x 20 et 1 connecteur rouge sur les électrodes (Remarque : les ressorts de traction agissent également comme auto-électriques)
- Connectez 5 résistances R 1 Mohm 1 W entre le connecteur rouge et l'électrode (dans un tube en plastique transparent)
-Vous pouvez également ajouter trois trous M3 dans un U autour d'un trou de sortie et installer une petite plaque avec un miroir collé et 3 vis M3 x 10 et 3 ressorts de poussée. Ajustez les vis pour aligner l'axe optique du miroir et le canal plasma (avec votre œil ou un petit pointeur laser rouge)
Remarque : Comment aligner le miroir : prenez une feuille de papier blanc, faites un trou de 1 mm au milieu. Déconnectez et déchargez le laser. Regardez à travers le trou du papier jusqu'au miroir à travers le trou de sortie laser. Alignez votre œil avec les électrodes et les vis de réglage du miroir jusqu'à ce que le trou de papier soit juste centré entre les 2 électrodes.
Picture: (CD is just for the scale, at left: mirror with 3 screws and 3 springs to adjust it, electrodes with 2 pull springs, nylon screws and Red HT connector, on the right: spark gap screw with a Black plastic disc)
Photo : (le CD est juste pour l'échelle. A gauche : miroir avec 3 vis et 3 ressorts pour le régler, électrodes avec 2 ressorts de traction, vis nylon et connecteur HT Rouge, à droite : vis d'éclateur avec disque plastique Noir)
Preliminary low tension tests:
On that prototype, capacitors are about 2 x 2 nF.
Safely powered with 10 VDC (only), spark gap "replaced" with an ILS switch triggered with a magnet, measured fall time on spark electrode is about 11 ns, fall time on self electrode (other) is about 60 ns. Self electrode fall time and period depends only from capacitor and self value. Here self is made with the 2 electrodes springs, anyway self value isn't very critical.
Picture: In grey the 2 electrodes tension, in black the difference between the two electrodes. Laser will work only during the first ns: between cursors. Sine wave is due to C capacitor and L inductor combination.
Essais préliminaires en basse tension :
Sur ce prototype, les condensateurs mesurent environ 2 x 2 nF.
Alimenté en toute sécurité avec 10 VDC (uniquement), l'éclateur "remplacé" par un interrupteur ILS déclenché par un aimant, le temps de descente mesuré sur l'électrode à éclateur est d'environ 11 ns, le temps de descente sur l'éclateur est d'environ 60 ns. Le temps et la période de descente de l'auto-électrode dépendent uniquement du condensateur et de sa valeur propre. Ici, la self est réalisé avec les 2 ressorts d'électrodes, de toute façon la valeur de la self n'est pas très critique.
Photo : En gris, la tension des 2 électrodes, en noir la différence entre les deux électrodes. Le laser ne fonctionnera que pendant les premières ns : entre les curseurs. L'onde sinusoïdale est due à la combinaison du condensateur C et de l'inductance L.
HT (High tension) test:
Your laser is now ready to operate! You must connect HT supply set at 10 kV. Now, be very careful; take care to high tension and laser emission. Once laser disconnected, capacitors can keep high tension for a long time. Safely discharge it (with an insulated screwdriver first connect to ground and then to electrode) before touching anything. Or better, take the habit to short-circuit the Black and Red connectors when not powering. (Black connected first then Red)
Once distance between electrodes set to 1.3 mm, spark gap distance set to 3 mm and tension set to 10 kV for a first test. Install a white paper sheet aligned with the laser output at some 500 mm from the output. Put a plastic blackbox on the spark gap, keep away and power on.
If anything is correct, spark gap occurs several times a second (10 Hz for example), you can see a purple plasma band between electrodes without (too much) white sparks. And a white point (about 4 x 1 mm ellipse) appears on the white paper.
Picture: Here laser power is low: this is preliminary HT test, HT is low and everything must be adjust. HT is only an old photocopier 5.5 kV module, electrodes distance is set to 1.25 mm, rear mirror is installed, it has been adjust with the eye though a 1 mm hole in a paper sheet disposed at the laser output hole (when laser was disconnected of course!)
Laser works also without mirror but at lower output power
Test HT (Haute Tension) :
Le laser est maintenant prêt à fonctionner ! Il faut raccorder l'alimentation HT réglée à 10 kV. Maintenant, soyez très prudent ; faites attention à la haute tension et à l'émission laser. Une fois le laser déconnecté, les condensateurs peuvent maintenir une tension élevée pendant une longue période. Déchargez-les en toute sécurité (avec un tournevis isolé, connectez-le d'abord à la terre puis à l'électrode) avant de toucher quoi que ce soit. Ou mieux, prenez l'habitude de court-circuiter les connecteurs Noir et Rouge lorsqu'ils ne sont pas sous tension. (Le noir connecté en premier puis le rouge)
Une fois la distance entre électrodes réglée à 1,3 mm, la distance de l'éclateur réglée à 3 mm et la tension réglée à 10 kV pour un premier test. Installez une feuille de papier blanc alignée avec la sortie laser à environ 500 mm de la sortie. Placez une boîte noire en plastique sur l'éclateur, tenez-vous à l'écart et allumez.
Si tout est correct, l'éclateur produit un éclat plusieurs fois par seconde (10 Hz par exemple), vous pouvez voir une bande de plasma violette entre les électrodes sans (trop) d'étincelles blanches. Et un point blanc (ellipse d'environ 4 x 1 mm) apparaît sur le papier blanc.
Photo : Ici, la puissance du laser est faible : il s'agit d'un test HT préliminaire, la HT est faible et tout doit être réglé. Le module HT n'est qu'un vieux module de photocopieur 5,5 kV, la distance des électrodes est réglée à 1,25 mm, le miroir arrière est installé, il a été réglé à l'œil grâce à un trou de 1 mm dans une feuille de papier disposée au niveau du trou de sortie du laser (lorsque le laser a été déconnecté bien sûr!)
Le laser fonctionne également sans miroir mais avec une puissance de sortie inférieure
You can now modify parameters trying to get the strongest light.
In case of problem:
- Be very careful with L electrode side used for plasma: shape must be round and surface must be perfectly line and smooth.
- The 2 electrodes must be perfectly // and at the right distance. I recommend using calliper or car spark plugs adjustment tools: those little iron plates from various thickness. You can also use a CD that is 1.2 mm thin. If electrodes are not //, you see more white sparks at the end where there are nearest: you must then adjust nylon screw to correct it.
Comments and improvements:
- The same laser can be realised bigger to improve output power
- Of course, using Nitrogen instead air will also increase laser output power (far more boring and expensive too :-)
- At atmospheric pressure, air (Nitrogen laser) channel width is little and pumping a dye with it (for visible laser) may be difficult. (I will try soon)
- Adding an insulated plate or wire // and just upper laser channel that acts as a Corona can perhaps stabilise plasma, decrease white sparks and increase efficiency.
- Adding a probe made with and old CD player phototransistor connected to the scope will help to improve laser and increase output power. Of course, phototransistor isn't fast enough to show optical output pulses but stronger the displayed pulse is and stronger the optical output is. (With my CD player phototransistor sample, short wave bandwidth phototransistor is enough to measure 337 nm Nitrogen pulse laser).
This probe use an old CD player phototransistor, all outputs are connected in // and to a 22 ohms resistor: a fluorescent yellow paper with a little hole in front of the phototransistor make position adjustment easy.
Vous pouvez désormais modifier les paramètres en essayant d'obtenir la lumière la plus forte.
En cas de problème :
- Soyez très soigneux avec le bord de l'électrode utilisée pour le plasma : la forme doit être ronde et la surface doit être parfaitement rectiligne et lisse.
- Les 2 électrodes doivent être parfaitement // et à bonne distance. Je recommande d'utiliser des outils de réglage comme un pied à coulisse ou des cales de réglages de bougies de voiture. Vous pouvez également utiliser un CD de 1,2 mm d'épaisseur. Si les électrodes ne sont pas //, vous voyez davantage d'étincelles blanches à l'extrémité là où elles sont les plus proches : il faut alors ajuster la vis nylon pour corriger.
Commentaires et améliorations :
- Le même laser peut être réalisé en plus grand pour améliorer la puissance de sortie
- Bien sûr, utiliser de l'azote à la place de l'air augmentera également la puissance de sortie du laser (beaucoup plus difficile et plus cher aussi :-)
- À pression atmosphérique, la largeur du canal d'air (laser à azote) est faible et le pompage d'un colorant avec (pour laser visible) peut être difficile.
- L'ajout d'une plaque ou d'un fil isolé // et juste d'un canal laser supérieur qui agit comme une couronne peut peut-être stabiliser le plasma, diminuer les étincelles blanches et augmenter l'efficacité.
- L'ajout d'une sonde réalisée avec un ancien phototransistor de lecteur CD connecté à l'oscilloscope permettra d'améliorer le laser et à augmenter la puissance de sortie. Bien sûr, le phototransistor n'est pas assez rapide pour afficher les impulsions de sortie optique, mais plus l'impulsion affichée est élevée et plus la sortie optique est forte. (Avec mon échantillon de phototransistor de lecteur CD, un phototransistor à bande passante à ondes courtes est suffisant pour mesurer un laser à impulsion d'azote de 337 nm).
Cette sonde utilise un vieux phototransistor de lecteur CD, toutes les sorties sont connectées en // et à une résistance de 22 ohms : un papier jaune fluo avec un petit trou devant le phototransistor facilite le réglage de la position.
Then probe is installed in front of the laser output (well, a luxurious 150$ PSU for a poor 10$ laser!)
Ensuite, la sonde est installée devant la sortie laser (enfin, un luxueux bloc d'alimentation à 150 € pour un pauvre laser à 10 € !)
Measurement: Of course, probe isn't fast enough: probe rise time is low: about 300 ns and fall time very low: some us. But higher is the electrical pulse and higher is the optical pulse: we are now able to precisely optimise laser!
Mesure : Bien entendu, la sonde n'est pas assez rapide : le temps de montée de la sonde est faible : environ 300 ns et le temps de descente très faible : certains us. Mais plus l’impulsion électrique est élevée et plus l'impulsion optique est élevée : nous sommes désormais capables d’optimiser le laser avec précision !
- I think that a fast high tension simple and safe probe (capacitor divider) can be built to allow user to measure real capacitors tension without burning the scope. A 50 x 50 mm rectangular aluminium plate which will act as a capacitor with ground. Adding a very little well insulated plate against one electrode, connect the little plate to the 50 x 50. One will make a high tension capacitor attenuator that we can connect to a scope probe.
- Je pense qu'une sonde haute tension rapide, simple et sûre (diviseur de condensateur) peut être construite pour permettre à l'utilisateur de mesurer la tension réelle des condensateurs sans dégrader l'oscilloscope. Une plaque rectangulaire en aluminium de 50 x 50 mm qui fera office de condensateur avec masse. En ajoutant une très petite plaque bien isolée contre une électrode, connectez la petite plaque au 50 x 50. On fera un atténuateur de condensateur haute tension que l'on pourra connecter à une sonde d' oscilloscope.
09/12/2023