Disclaimer: Not all of our projects are displayed here, as we respect customers who highly value their privacy.
On this page, you’ll find a glimpse of the projects we’ve completed over the past two years. From small-scale jobs to large-scale projects, we handle them all — provided the investment makes sense, we deliver with full dedication.
With us, it’s never about “just getting it done” — it’s about doing it right, safe, and professionally.
Before:
Whenever the C32 MCB was switched on, the entire house tripped. The issue was caused by a short between the neutral and earth wires in two of the upstairs rooms.
After:
Our solution was to carry out insulation testing to trace and identify the exact fault point that caused the short circuit.
Before:
The previous electrician installed a 300mA ELCB for this house. However, a 300mA rating is meant for industrial applications and is not suitable for residential use.
After:
We traced the source of the short circuit and replaced the ELCB with a 30mA unit, which is the correct and safer standard for household protection.
Before:
Neutral & earth shorted
Weak and unsafe earthing system
After:
Fault traced & fully repaired
Brand-new earthing system (tested <10Ω)
Result:
Safe, compliant, and future-ready electrical system — another happy homeowner!
Want your home safe like this?
Click “WhatsApp Us” now and get a FREE safety inspection quote!
When we first arrived, this cabin home was at serious electrical risk:
Phase-to-phase shorting
Phase-to-earth shorting
Improper (and potentially dangerous) earthing system
Wrong type of Earth Leakage Circuit Breaker installed
Expert Tracing & Repair: Identified and rectified all shorting issues from the distribution board (DB) to the load.
Premium Earthing Upgrade: Installed a high-quality earthing system with a resistance reading below 10Ω for maximum safety.
New Metal Distribution Box: Ensuring durability and compliance with modern safety standards.
JKR-Approved Safety Breaker: Replaced with a trusted brand for reliable protection.
Result: Safe, compliant, and future-ready electrical system — giving the homeowner total peace of mind.
Weak and unsafe earthing system
Several household appliances were damaged, including the air conditioner, ceiling fans, refrigerator, and other electrical equipment.
Lack of water heater safety 10mA
This is an old house that has been facing numerous electrical issues. The original wiring was done poorly and did not follow proper specifications, which led to frequent damages and safety concerns. The homeowner has now entrusted us to carry out a complete rewiring of the house. Our service comes with a 5-year warranty, ensuring quality, safety, and peace of mind.
replace old waterproof socket to a brand new
The homeowner complained that their electricity bill had increased drastically, from around RM100 to RM400 per month.
Cause: Multiple looping power circuits installed with undersized 1.0mm wires.
Solution: Replace the existing wiring with larger capacity cables, such as 2.5mm, to safely handle higher current flow and ensure system stability.