L Zou, R Liu, S Hashem, JF Lo, "Stain-free LED Scanning Lifetime Imaging System for Diabetes Modified Tissue Matrices." Review of Scientific Instruments 2018, 89(12): 075812RSI
K Duan, G Ghosh, JF Lo, “Optimizing Multiplexed Detections of Diabetes Antibodies via Quantitative Microfluidic Droplet Array.” Small 2017 (accepted, smll.201702323R1) - [EMID:ccf5c4c911529960]
M-B Habhab, T Ismail, JF Lo, “Laminar Flow Based Microfluidic Tesla Pump via Lithography Enabled 3D Printing”. Sensors 2016, 16(11), 1970; doi:10.3390/s16111970
L Zou, R Koslakiewicz, M Mahmoud, M Fahs, R Liu, JF Lo, “3D Printed Miniaturized Spectral System for Collagen Fluorescence Lifetime Measurements,” Journal of Biomedical Optics 2016, 21(7), 075001
Z Zhao, MA Al-Ameen, K Duan, G Ghosh, JF Lo, “On-chip porous microgel generation for microfluidic enhanced VEGF detection,” Biosensors and Bioelectronics 2015,74:305-312
JY Lee, Y Park, S Pun, SS Lee, JF Lo, LP Lee, “Real-time investigation of cytochrome c release profiles in living neuronal cells undergoing amyloid beta oligomer-induced apoptosis,” Nanoscale 2015, DOI: 10.1039/c5nr02390d
R Liu, Z Zhao, L Zou, Q Fang, L Chen, A Argento, JF Lo, “Compact, non-invasive frequency domain lifetime differentiation of collagens and elastin,” Sensors and Actuators B:Chemical 2015, 219, pp.283-293
Z Li, D Hu, Z Zhao, M Zhou, R Liu, JF Lo, " Balancing Diffusion and Convection in a Spiral Oxygen Gradient Modulates Fibroblast VEGF," Biomedical Microdevices 2015, 17(1): p1-9
JF Lo†, M Brennan, Z Merchant, L Chen, DT Eddington, LA DiPietro, “Microfluidic Wound Bandage: Localized Oxygen Modulation of Collagen Maturation,” Wound Repair and Regeneration 2013, 21(2):226-234. †corresponding author.
JF Lo, Y Wang, Z Li, Z Zhao, D Hu, DT Eddington, J Oberholzer, “Quantitative and Temporal Control of Oxygen Microenvironment at the Single Islet Level,” Journal Visualized Experiment 2013, e50616, doi:10.3791/50616
M Nourmohammadzadeh†, JF Lo†, M Bochenek, JE Mendoza-Elias, Q Wang, Z Li, L Zeng, M Qi, DT Eddington, J Oberholzer, Y Wang, ”Microfluidic Array with Integrated Oxygenation Control for Real-Time Live-Cell Imaging: Effect of Hypoxia on Physiology of Microencapsulated Pancreatic Islets,” Analytical Chemistry 2013, 85 (23): 11240-11249. †equal contributions
G Mauleon, JF Lo, BL Peterson, C Fall, DT Eddington, “Enhanced Loading of Fura-2/AM Calcium Indicator Dye in Adult Rodent Brain Slices Via a Microfluidic Oxygenator,” Journal of Neuroscience Methods 2013, 216 (2):110-117
JF Lo, Y Wang, J Oberholzer, and DT Eddington, “Microfluidic Control of Hypoxia Aids Investigations of Islet Pathophysiology,” Micro and Nanosystems 2013, 5(3): 209-215.
Y Wang, JE Mendoza-Elias, JJ McGarrigle, M Nourmohammadzadeh, Q Wang, Z Li, B Rady, F Feng, M Qi, JF Lo, David T Eddington, Jose Oberholzer, “Application of Microfluidic Technology for Studying Islet Physiology and Pathophysiology”, Micro and Nanosystems 2013, 5(3):216-223.
JF Lo, Y Wang, A Blake, G Yu, TA Harvat, H Jeon, J Oberholzer, DT Eddington, “Islet Preconditioning via Multimodal Microfluidic Modulation of Intermittent Hypoxia,” Analytical Chemistry 2012, 84 (4): 1987–1993.
Y Wang, JF Lo, J Mendoza-Elias, AF Adewola, TA Harvat, M Qi, KP Kinzer, DT Eddington, J Oberholzer, “Applied Microfluidic Technology in Pancreatic Islet Research: 10 Years of Innovation,” Bioanalysis 2010, 2(10):1729-44.
JF Lo, E Sinkala, DT Eddington, “Oxygen Gradients for Open Well Cellular Cultures via Microfluidic Substrates,” Lab on a Chip 2010, 10:2394-401. A
JF Lo, P Butte, Q Fang, SJ Chen, T Papaioannou, ES Kim, M Gundersen, L Marcu, “Multilayered MOEMS Tunable Spectrometer for Fluorescence Lifetime Detection,” Photonics Technology Letters 2010, 22(7):486-8.
JF Lo, SJ Chen, Q Fang, T. Papaioannou, ES Kim, M Gundersen, L Marcu, “Performance of a Diaphragmed Microlens for a Packaged Microspectrometer,” Sensors 2009, 9(2):859-68.
JR Scherer, BM Paegel, GJ Wedemayer, C A Emrich, JF Lo, IL Medintz, RA Mathies, “High-pressure Gel Loader for Capillary Array Electrophoresis Microchannel Plates,” Biotechniques 2001, 31(5):1150-4.
Chapters in books
Y Wang, JE Mendoza-Elias, JF Lo, TA. Harvat, F Feng, Z Li, Q Wang, M Nourmohammadzadeh, D Gutierrez, M Qi, DT Eddington, J Oberholzer. “Chapter 16: Microfluidics for Monitoring and Imaging Pancreatic Islet and β-cells for Human Transplant.” In XiuJun James Li (eds), Microfluidic Devices for Biomedical Applications. Woodhead Publishing 2013, p557-593.
Conferences or symposiums
Podium:
L Zou, M Mahmoud, M Fahs, F Choughari, K Duan, JF Lo, “3D Printed Miniaturized System for Multispectral Tissue Fluorescence Lifetime Measurements,” The International Society for Optics and Photonics (SPIE)Photonics West 2016.
M-B Habhab, T Ismail, JF Lo, “Aqueous Gradient by Balancing Diffusive and Convective Mass Transport,” SPIE Photonics West 2016.
K Duan, Z Zhao, MA Al-Ameen, G Ghosh, JF Lo, “Smart Microgels: Autoantibody Detection and Disease Modeling on a Chip,” Biomedical Engineering Society Annual Meeting 2015.
Z Zhao, MA Al-Ameen, K Duan, D Hu, G Ghosh, JF Lo, “Nanoplasmonic Microparticles: Enhanced Sensitivity for High-throughput Bioassay,” SPIE Photonics West 2015.
R Liu, Z Zhao, M Zhou, Q Fang, A Argento, JF Lo, “Noninvasive Frequency Domain Tissue Collagen Detection,” Biomedical Engineering Society Annual Meeting 2014.
Z Li, Z Zhao, JF Lo, “Rapid Prototyping of Multiphase Microfluidics with Robotic Cutters”, SPIE Photonics West 2014
Z Zhao, Z Li, R Liu, JF Lo, “Spectral and Frequency-domain Collagen Detection of Spherical Ocular Tissue”, SPIE Photonics West 2014
JF Lo, M Brennan, Z Merchant, Z Nie, Q Fang, L Chen, L DiPietro, DT Eddington, “Microfluidic Bandage: Simultaneous Oxygen Delivery and Monitoring Collagen for Wound Therapy,” Biomedical Engineering Society Annual Meeting 2012.
Poster:
M-B Habhab, JF Lo, “Tesla Inspired Pump and Microfluidic Gradient Realized with Lithography Based Additive Manufacturing,” Solid State Sensors and Actuators (Transducers) 2017, 0820.
K Duan, G Ghosh, JF Lo, “On-chip Porous Microgel Based Insulin Autoantibody (IAA) Detection for Type I Diabetes Diagnostics,” Miniaturized Systems for Chemistry and Life Sciences (MicroTAS) 2016, 0956.
R Favot, M Zhou, JF Lo, “Rapid Formation of a Stable, Large Area Hypoxia Gradient,” Biomedical Engineering Society Annual Meeting 2015.
R Liu, Z Zhao, M Zhou, V.N. Du Le, Q Fang, JF Lo, “Wound collagen monitoring with low-cost noninvasive LED system,” SPIE Photonics West 2015.
M Zhou, Z Li, Z Zhao, D Hu, R Liu, JF Lo, “Spiral Microfluidic Gas Gradients by Balancing Diffusion and Convection,” MicroTAS 2014, 0653.
Zhao, R Liu, D Hu, JF Lo, “Monolithic Droplet Generator and Microarray for Screening Islet Beta Cells,” MicroTAS 2014, 0647.
D Hu, Z Zhao, G Ghosh, JF Lo, “Droplet Generation and Trapping for High-throughput Bioassay,” Biomedical Engineering Society Annual Meeting 2014.
M Zhou, K Milliman, Z Zhao, M Wang, N Chakraborty, JF Lo, “Modeling Spiral Oxygen Gradient for Simultaneous Hypoxic Stimulation and Cell Respiration Monitoring,” Biomedical Engineering Society Annual Meeting 2014.
F Choughari, M Mahmoud, JF Lo, “On-chip Oxygen Gradient Stimulation of Pancreatic Beta Cells,” Undergraduate Session, Biomedical Engineering Society Annual Meeting 2014.
Z Li, Z Zhao, R Liu, JF Lo, “Simultaneous O2 and CO2 Measurements Localized in an Open Top Microfluidic Cell Culture”, Biomedical Engineering Society Annual Meeting 2013.