Textbook "Biomechanics of Joints: Concepts to Application" published by Springer Nature Singapore
Online version available at https://link.springer.com/book/10.1007/978-981-96-0586-6
Saviour, C. M., Senapati, R., Mohanty, B., and Gupta, S. (2025) "Optimal design of a functionally graded porous uncemented acetabular component: a Kriging model‑based computational framework", Structural and Multidisciplinary Optimization, 68, 117. https://doi.org/10.1007/s00158-025-04037-4.
Vaidya, P.V., Seesala, V.S., Talukdar, R.G., Biswas, A., Jana, S., Yadav, M.K., Rajasekaran, R., Dogra, N., Roy, T., Mukherjee, S., Bagde, A., Dabhade, P., Syed, Z.Q., Fulzele, P., Gupta, S., Bandyopadhyay, T.K. and Dhara, S. (2025), Highly Interconnected Ti6V4Al Foam with Tailorable Pore Architecture and Mechanical Property by Powder Processing for Skeletal Tissue Ingrowth. Advanced Engineering Materials, 27, 2401630. https://doi.org/10.1002/adem.202401630.
Talukdar, R. G., Dhara, S., and Gupta, S. (2024). "Bone ingrowth in randomly distributed porous interbody cage during lumbar spinal fusion". Medical Engineering and Physics, 133, 104248. https://doi.org/10.1016/j.medengphy.2024.104248.
Saviour, C. M., and Gupta, S. (2024). "Towards an optimal design of a functionally graded porous uncemented acetabular component using genetic algorithm". Medical Engineering and Physics, 126, 104159. https://doi.org/10.1016/j.medengphy.2024.104159.
Talukdar, R. G., Dhara, S., and Gupta, S. (2024). "Bone ingrowth in randomly distributed porous interbody cage during lumbar spinal fusion". Medical Engineering and Physics, 133, 104248. https://doi.org/10.1016/j.medengphy.2024.104248.
Saviour, C. M., Mathai, B., and Gupta, S. (2024). "Mechanobiochemical Bone Remodelling around an Uncemented Acetabular Component: Influence of Bone Orthotropy". Medical & Biological Engineering & Computing, 62(6), 1717–1732. https://doi.org/10.1007/s11517-024-03023-0
Talukdar, R. G., Saviour, C. M., Dhara, S., and Gupta, S. (2023). "Biomechanical Analysis of Functionally Graded Porous Interbody Cage For Lumbar Spinal Fusion". Computers in Biology and Medicine, 164, 107281. https://doi.org/10.1016/j.compbiomed.2023.107281.
Saviour, C. M., Gupta, S. (2023). "Design of a functionally graded porous uncemented acetabular component: Influence of polar gradation". International Journal for Numerical Methods in Biomedical Engineering, 39(6), e3709. https://doi.org/10.1002/cnm.3709.
Saviour, C. M., Chowdhury, J. B., Gupta, S. (2023). "Numerical evaluations of an uncemented acetabular component in Total Hip Arthroplasty: Effects of loading and interface conditions." Trans. ASME. Journal of Biomechanical Engineering, 145(2), 021009. https://doi.org/10.1115/1.4055760.
Dutta, A., Mukherjee, K., Seesala, V. S., Dutta, K., Paul, R. R., Dhara, S., Gupta, S. (2023). "Comparative Evaluation of a Patient-specific Customised Plate Designs and Screws for Partial Mandibular Reconstruction." Medical Engineering and Physics, 111, 103941. https://doi.org/10.1016/j.medengphy.2022.103941.
Dutta, S., Khan, R., Prakash, N. S., Gupta, S., Ghosh, D., Nandi, S. K., Roy, M. (2022). "In Vitro Degradation and In Vivo Biocompatibility of Strontium-Doped Magnesium Phosphate-Reinforced Magnesium Composites." ACS Biomaterials Science & Engineering, 8(10), 4236–48. https://doi.org/10.1021/acsbiomaterials.2c00142.
Talukdar, R. G., Saviour, C. M., Tiwarekar, K., Dhara, S., Gupta, S. (2022). "Bone Remodelling Around Solid and Porous Interbody Cages in the Lumbar Spine." Trans. ASME. Journal of Biomechanical Engineering, 144(10), 101011. https://doi.org/10.1115/1.4054457.
Mathai, B., Dhara, S., Gupta, S. (2022). "Bone remodelling in implanted proximal femur using topology optimization and parameterized cellular model". Journal of the Mechanical Behavior of Biomedical Materials, 125, 104903. https://doi.org/10.1016/j.jmbbm.2021.104903.
Mathai, B., Gupta, S. (2022). "Bone Ingrowth Around an Uncemented Femoral Implant Using Mechanoregulatory Algorithm: A Multiscale Finite Element Analysis". Trans. ASME, Journal of Biomechanical Engineering, 144(2), 021004-10.
Talukdar, R. G., Mukhopadhyay, K. K., Dhara, S., Gupta, S. (2021). "Numerical analysis of the mechanical behaviour of intact and implanted lumbar functional spinal units: Effects of loading and boundary conditions". Proc Instn Mech Engrs: Part H, Journal of Engineering in Medicine, 235(7), 792–804.
Mathai, B., Dhara, S., Gupta, S. (2021). "Orthotropic bone remodelling around uncemented femoral implant: a comparison with isotropic formulation". Biomechanics and Modeling in Mechanobiology. 20(3), 1115–1134.
Dutta, S., Mandal, S., Gupta, S., & Roy, M. (2020). "Effects of cerium addition on the corrosion resistance and biocompatibility of Mg–2Sr–1Zr Alloy". Journal of Materials Research, 35(22), 3124-3135.
Pal, B., Gupta, S. (2020). "The Relevance of Biomechanical Analysis in Joint Replacements: A Review". J Inst. Eng India Ser. C, 101, 913–927 .
Mathai B., Gupta S. (2020). "The influence of loading configurations on numerical evaluation of failure mechanisms in an uncemented femoral prosthesis", International Journal for Numerical Methods in Biomedical Engineering, 36(8), e3353. https://doi.org/10.1002/cnm.3353.
Chanda S., Mukherjee K., Gupta S. , Pratihar D. K. (2020), “A comparative assessment of two designs of hip stem using rule-based simulation of combined osseointegration and remodeling”, Proc Instn Mech Engrs: Part H, Journal of Engineering in Medicine, 234, 118-128.
Dutta A, Mukherjee K, Seesala VS, Dutta K, Paul RR, Dhara S, Gupta S. (2020), "Load transfer across a mandible during a mastication cycle: The effects of odontogenic tumour", Proc Instn Mech Engrs: Part H, Journal of Engineering in Medicine, 234, 486-495.
Mathai B. and Gupta S. (2019) ,“Numerical predictions of hip joint and muscle forces during daily activities: a comparison of musculoskeletal models”, Proc Instn Mech Engrs: Part H, Journal of Engineering in Medicine, 233(6), 636–647.
Dutta A., Mukherjee K., Dhara S., Gupta S. (2019), “Design of porous titanium scaffold for complete mandibular reconstruction: The influence of pore architecture parameters”, Computers in Biology and Medicine, 108, 31-41.
Dutta S., Devi B. K., Mandal S. , Mahato A. , Gupta S. , Kundu B. , Balla V. , Roy M. (2019), “In Vitro Corrosion and Cytocompatibility Studies of Hot Press Sintered Magnesium-Bioactive Glass Composite”, Materialia, 5, 100245.
Dutta S., Karuppasamy, B., Gupta S., Kundu B., Balla V., Roy M. (2018), “Mechanical and in vitro degradation behavior of magnesium-bioactive glass composites prepared by SPS for biomedical applications”, Journal of Biomedical Materials Research: Part B - Applied Biomaterials, 107(2), 352-365.
Mukherjee K., Gupta S. (2017), “Combined Bone Ingrowth and Remodelling around Uncemented Acetabular Component: a Multiscale Mechanobiology based Finite Element Analysis”, Trans. ASME, Journal of Biomechanical Engineering, 139(9), 091007-1–12.
Mukherjee K., Gupta S. (2017), “Influence of Implant Surface Texture Design on Peri-acetabular Bone Ingrowth: A Mechanobiology Based Finite Element Analysis”, Trans. ASME, Journal of Biomechanical Engineering, 139(3), 031006-1–8.
Mukherjee K., Gupta S. (2017), “Mechanobiological simulations of peri-acetabular bone ingrowth: a comparative analysis of cell-phenotype specific and phenomenological algorithms”, Medical & Biological Engineering & Computing, 55(3), 449 – 465.
Mukherjee K. and Gupta S. (2016), “The effects of musculoskeletal loading regimes on numerical evaluations of acetabular component”, Proc Instn Mech Engrs: Part H, Journal of Engineering in Medicine, 230(10), 918-929.
Mukherjee K. and Gupta S. (2016), “Bone Ingrowth around Porous Coated Acetabular Implant: A Three-dimensional Finite Element Study using Mechanoregulatory Algorithm”, Biomechanics and Modeling in Mechanobiology, 15(2), 389-403.
Chanda S., Gupta S., Pratihar D.K. (2016), “A combined neural network and genetic algorithm based approach for optimally designed femoral implant having improved primary stability”, Applied Soft Computing , 38, 296-307.
Chanda S., Gupta S., Pratihar D.K. (2016), “Effects of Interfacial Conditions on Shape Optimization of Cementless Hip Stem: an Investigation Based on a Hybrid Framework”, Structural and Multidisciplinary Optimization, 53, 1143-1155.
Chanda S, Dickinson A, Gupta S and Browne M. (2015), “Full-field in vitro measurements and in silico predictions of strain shielding in the implanted femur after total hip arthroplasty”, Proc Instn Mech Engrs: Part H, Journal of Engineering in Medicine, 229(8), 549-559.
Chanda S., Gupta S., Pratihar D.K. (2015), “A Genetic Algorithm Based Multi-objective Shape Optimization Scheme for Cementless Femoral Implant”, Trans. ASME, Journal of Biomechanical Engineering, 137, 034502 (1-12).
Ghosh R., Pratihar D.K., Gupta S. (2015), “Towards Optimal Design of an Uncemented Acetabular Component Using Genetic Algorithms”, Engineering Optimization, 47 (12), 1587-1601.
Ghosh R., Pal B., Ghosh D., Gupta S. (2015), “Finite element analysis of a hemi-pelvis: the effect of inclusion of cartilage layer on acetabular stresses and strain", Computer Methods in Biomechanics and Biomedical Engineering, 18 (7), 697-710.
Ghosh, R. and Gupta, S. (2014), "Bone remodelling around cementless composite acetabular components: The effects of implant geometry and implant–bone interfacial conditions", Journal of the Mechanical Behavior of Biomedical Materials, 32, 257 – 269.
Ghosh R., Mukherjee K., Gupta S. (2013), “Bone remodelling around uncemented metallic and ceramic acetabular components”, Proc. Instn. Mech. Engrs, Part H, Journal of Engineering in Medicine, 227(5), 490 – 502.
Ghosh R., Gupta S., Dickinson A., Browne M. (2013), “Experimental validation of numerically predicted strain and micromotion in intact and implanted composite hemi-pelvises”, Proc Instn Mech Engrs: Part H, Journal of Engineering in Medicine, 227(2), 162 – 174.
Ghosh R., Gupta S., Dickinson A., Browne M. (2012), “Experimental validation of finite element models of intact and implanted composite hemi-pelvises using digital image correlation”, Trans. ASME, Journal of Biomechanical Engineering, 134(8), 081003(1 – 9).
Pal B. and Gupta S. (2011), “The effect of primary stability on load transfer and bone remodelling within the uncemented resurfaced femur”, Proc Instn Mech Engrs: Part H, Journal of Engineering in Medicine, 225 (6), 549 – 561.
Pal B., Gupta S., New A.M.R. (2010), “Influence of the change in stem length on the load transfer and bone remodelling for a cemented resurfaced femur”, Journal of Biomechanics , 43 (15), 2908 – 2914.
Pal B., Gupta S., New A.M.R., Browne M. (2010), “Strain and micromotion in intact and resurfaced composite femurs: experimental and numerical investigations”, Journal of Biomechanics, 43 (10), 1923 – 1930.
Gupta S., Pal B., New A.M.R. (2010), “The effects of interfacial conditions and stem length on potential failure mechanisms in the uncemented resurfaced femur”, Annals of Biomedical Engineering, 38(6), 2107-2120.
Junaid S., Gupta S., Sanghavi S., Hansen U.N., Anglin C., Emery R, Amis A. (2010), “Failure mechanism of the all-polyethylene glenoid implant”, Journal of Biomechanics , 43(4), 714 – 719.
Pal B., Gupta S., New A.M. (2010), “Design considerations for ceramic resurfaced femoral head: effect of interface characteristics on failure mechanisms”, Computer Methods in Biomechanics and Biomedical Engineering, 13: 2, 143 – 155.
Pal B., Gupta S., New A.M. (2009), “A numerical study of failure mechanisms in the cemented resurfaced femur – effects of interface characteristics and bone remodelling”, Proc Instn Mech Engrs: Part H, Journal of Engineering in Medicine, 223(4), 470 – 484.
Gupta S., New A.M.R., Taylor M. (2006), “Bone remodelling inside a cemented resurfaced femoral head”, Clinical Biomechanics , 21, 594 – 602.
Van der Helm F.C.T. and Gupta S. (2005), Reply to: “The scapula is a sesamoid bone”, letter to the editor by Dr. Stephen M. Levin”, Journal of Biomechanics, 38(8), 1734 – 1736.
Gupta S. and Dan P. (2004), "Bone geometry and mechanical properties of the human scapula using computed tomography data", Trends in Biomaterials and Artificial Organs, 17(2), 61 – 71.
Gupta S., Van der Helm F.C.T., Van Keulen F. (2004), “Stress analysis of cemented glenoid prostheses in Total Shoulder Arthroplasty”, Journal of Biomechanics, 37(11), 1777 – 1786.
Gupta S. and Van der Helm F.C.T. (2004), “Load transfer across the scapula during humeral abduction”, Journal of Biomechanics, 37(7), 1001 – 1009.
Gupta S., Van der Helm F.C.T., Sterk J.C., Van Keulen F., Kaptein B.L. (2004), “Development and experimental validation of a three-dimensional finite element model of the human scapula”, Proc Instn Mech Engrs: Part H, Journal of Engineering in Medicine, 218(2), 127-142.
Gupta S., Van der Helm F.C.T., Van Keulen F. (2004), “The possibilities of uncemented glenoid prosthesis – a finite element study”, Clinical Biomechanics, 19(3), 292-302.
Saviour, C. M. and Gupta, S (2025). Tissue ingrowth around a functionally graded porous acetabular component using a novel mechanobioregulatory framework. TERMIS-EU 2025, May 19 - 23, 2025, Freiburg, Germany.
Saviour, C. M. and Gupta, S (2024). Design optimization of a functionally graded porous acetabular component using genetic algorithm. 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC2024), July 9 – 12, 2024, Orlando, USA.
Saviour, C. M. and Gupta, S (2024). Bone ingrowth around a uncemented acetabular component: Influence of biphasic stimulus and poroelastic model. 29th Congress of European Society of Biomechanics (ESB2024), June 30 – July 3, 2024, Edinburgh, United Kingdom.
Talukdar, R. G., Dhara, S and Gupta, S. (2024). Bone ingrowth in porous interbody cage for lumbar spinal fusion. 29th Congress of European Society of Biomechanics (ESB2024), June 30 – July 3, 2024, Edinburgh, United Kingdom.
Saviour, C. M. and Gupta, S (2023). Orthotropic Bone Remodeling Around Uncemented Acetabular Component. XXIX Congress of International Society of Biomechanics (ISB2023), July 30 - August 3, 2023, Fukuoka, Japan.
Saviour, C. M., Mathai, B., Gupta, S (2023). Mechanobiochemical Based Orthotropic Bone Remodeling Around Uncemented Acetabular Component. 28th Congress of European Society of Biomechanics (ESB2023), July 9-12, 2023, Maastricht, The Netherlands.
Saviour, C. M., Mathai, B., Gupta, S (2022). Stress Analysis of a Natural Hemipelvis During Daily Activities. 9th World Congress of Biomechanics, July 10-14, 2022, Taipei, Tawian.
Saviour, C. M., Talukdar, R. G., Gupta, S. (2022),"Preclinical analysis of an implanted hemipelvis during daily activities: effects of interface conditions", In: Proc. 9th World Congress of Biomechanics, July 10 - 14, 2022, Taipei, Taiwan.
Talukdar, R. G. and Gupta, S. (2022), "Bone remodelling around a solid interbody cage in the lumbar spine", In: Proc. 9th World Congress of Biomechanics, July 10 - 14, 2022, Taipei, Taiwan.
Mukherjee K. and Gupta S. (2018), "A multiscale mechanobiology based finite element study on combined bone ingrowth and remodelling around uncemented acetabular component", In: Proc. 8th World Congress of Biomechanics, July 7 - 12, 2018, Dublin, Ireland.
Dutta A., Mukherjee K. , Dhara S. , Gupta S. (2018), "A numerical investigation on the influence of location and size of lesion on load transfer in an osteonecrotic mandible", In: Proc. 8th World Congress of Biomechanics, July 7 - 12, 2018, Dublin, Ireland.
Dutta A., Mukherjee K. , Dhara S. , Gupta S. (2018), "Design of 3D-printed patient-specific porous titanium scaffolds for total mandibular reconstruction: a multiscale finite element study", In: Proc. 8th World Congress of Biomechanics, July 7 - 12, 2018, Dublin, Ireland.
Mathai B., Gupta S. (2018), "Numerical estimation of hip contact and muscle forces during normal walking: a comparison of musculoskeletal models", In: Proc. 8th World Congress of Biomechanics, July 7 - 12, 2018, Dublin, Ireland.
Mathai B., Gupta S. (2018), "The effects of multiple loading regimes on pre-clinical evaluations of uncemented femoral prosthesis", In: Proc. 8th World Congress of Biomechanics, July 7 - 12, 2018, Dublin, Ireland.
Mukherjee K and Gupta S. (2017), “The Effect of Implant Surface Texture Design on Peri-acetabular Bone Ingrowth: A Multiscale Mechanobiology Based Numerical Analysis”, In: Proc. TERMIS-EU 2017, June 26 - 30, 2017, Davos, Switzerland.
Dutta A., Mukherjee K., Dhara S., Gupta S. (2017), "Influence of fiber spacing on mechanical properties of lattice structured titanium bone grafts: A three-dimensional finite element study", In: Proc. TERMIS-EU 2017, June 26 - 30, 2017, Davos, Switzerland.
Mukherjee K and Gupta S. (2015), “The Effects of Cellular Activities on Acetabular Cup Fixation: A Parametric Study using Three-Dimensional Finite Element Analysis”, 28th Annual Congress of The International Society for Technology in Arthroplasty (ISTA), September 30 – October 3, 2015, Vienna, Austria.
Chanda S., Gupta S., Pratihar D.K. (2015), “Shape Optimization of Femoral Implant based on a Machine Learning Framework and Assessment of the Optimum Design using Evolutionary Interface”, 28th Annual Congress of The International Society for Technology in Arthroplasty (ISTA), September 30 – October 3, 2015, Vienna, Austria.
Mukherjee K, Gupta S. (2014), “Investigations on Bone Ingrowth on a Porous Coated Implant using Three-dimensional Finite Element Analysis and Mechano-regulatory Algorithm.” In: Proc. 7th World Congress of Biomechanics, July 6-11, 2014, Boston, MA.
Chanda S., Dickinson A., Gupta S., Ozturk H., Browne M. (2014), “Prediction of Bone Remodeling after Total Hip Arthroplasty Using Digital Image Correlation on an Analogue Bone Model” In: Proc. 7th World Congress of Biomechanics, July 6-11, 2014, Boston, MA.
Chanda S., Pratihar D.K., Gupta S. (2014) ,“Shape Optimization of Cementless Hip Prosthesis.” In: Proc. 7th World Congress of Biomechanics, July 6-11, 2014, Boston, MA.
Ghosh R., Pratihar D.K., Gupta S. (2014), “Towards an Optimal Design of Uncemented Acetabular Component using Genetic Algorithms.” In: Proc. 7th World Congress of Biomechanics, July 6-11, 2014, Boston, MA.
Mukherjee K, Gupta S. (2014), “Comparison between Phenomenological and Cell-phenotype Specific Algorithms to Quantify Mechanoregulatory Peri-prosthetic Bone Ingrowth: A Three Dimensional Finite Element Study.” 12th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering, October 13 - 15, 2014, Amsterdam, The Netherlands.
Chanda S., Pratihar D.K., Gupta S. (2014), “Towards an Optimally Designed Cementless Hip Stem: a Multiobjective Genetic Algorithm based Approach.” 12th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering, October 13 - 15, 2014, Amsterdam, The Netherlands.
Ghosh R., Gupta S., Dickinson A., Browne M. (2012), Verification of the digital image correlation technique for bone surface strain measurements. In: Proc. 18th European Society of Biomechanics Conference, July 2012, Lisbon, Portugal. J. Biomechanics, Vol 45, S277.
Mukherjee K, Pal B, Gupta S. (2012), Analysis of Failure Mechanisms in Cemented Short-Stem Femoral Resurfacing Implant. In: Proc. 25th Annual Congress of the International Society for Technology in Arthroplasty, Sydney, Australia, October 3-6, 2012. Bone and Joint Journal Orthopaedic Proceedings, 2013, Vol 95-B (Suppl 15), 185.
Mukherjee K, Pal B, Gupta S. (2012), Bone adaptation around a cemented short-stem ceramic femoral resurfacing component. In: Proc. 18th European Society of Biomechanics Conference, July 2012, Lisbon, Portugal. J. Biomechanics, Vol 45, S99.
Ghosh R., Pal B., Ghosh D., Gupta S. (2011), “Load transfer across the pelvic bone during normal walking.” In: Proc. 35th Annual Meeting of American Society of Biomechanics, August 2011, Long Beach, California.
Ghosh R., Gupta S., Dickinson A, Browne M (2011), “Experimental validation of a finite element model of the composite pelvis using digital image correlation.” In: Proc. 35th Annual Meeting of American Society of Biomechanics, August 2011, Long Beach, CA.
Pal B., Gupta S., New A.M.R. (2010), “Effects of Change in Stem Length on the Mechanics of a Resurfaced Femur.” In: Proc. 6th World Congress of Biomechanics, August 2010, Singapore.
Ghosh R., Pal B., Ghosh D., Gupta S., New A.M.R., Browne M (2010), “Finite element analysis of uncemented acetabular component designs.” In: Proc. 6th World Congress of Biomechanics, August 2010, Singapore.
Pal B., Gupta S., New A.M.R. (2010), “A Numerical Study Exploring the Possibilities of Cementless Femoral Resurfacing.” In: Proc. 17th European Society of Biomechanics Conference, July 2010, University of Edinburgh, United Kingdom.
Ghosh R., Pal B., Ghosh D., Gupta S., New A.M.R. (2010), “Pre-clinical analysis of uncemented metallic acetabular component.” In: Proc. 17th European Society of Biomechanics Conference, July 2010, University of Edinburgh, United Kingdom.
Pal B., Ghosh D., Gupta S., New A.M.R. (2010), “Experimental measurement of strains and micromotions in the resurfaced femur.” In: Proc. 17th European Society of Biomechanics Conference, July 2010, University of Edinburgh, United Kingdom.