Wind Tunnel
Model: Longwin LW-9300R
Flow Speed: 0 - 100 m/s
Test Section Size: 0.3 x 0.3 x 1.0 m
Location: Maritime Centre, Faculty of Engineering
Force Balance (Single Mount)
3-component force balance
Lift measurement: 0 - 3000 gram force (gf)
Drag measurement: 0 - 2000 gram force (gf)
Moment measurement: 0 - 10 Nm
Pitot Tube
For point measurement of flow velocity at any position inside the wind tunnel test section
Smoke Visualization
Operating speed: 0 - 10 m/s
Oil Type: Glycerin
Hot Wire Anemometer
Operating range: 0.5 - 30 m/s
Data Acquisition and Visualisation Software
DAVis version 10
Laser generator
Quantel Evergreen laser
Laser type: Nd:YAG
Wavelength: 532 nm
To illuminate seeding particle
Aerosol generator
Max pressure: 6 bar
Recommended liquid: DEHS, Vegetable oil
Used in PIV particle seeding
Laser guiding arm & optical lens
Laser sheet thickness: 0.5 - 2.5 mm
Aperture: f = -10 mm or -20 mm
PIV camera
LAVISION imager SX CCD imaging camera
Camera lens
Nikon 50 mm lens
SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM
VSys SCADA
Channel 1-16: Pressure valve
Port 0-5: Pressure transducer
DATA LOGGER
National Instrument Compact Rio
Converting analog data from sensor to electronic signal
PRESSURE TRANSDUCERS
4 Omega general pressure transducer
Operating pressure: 0-15 psi (Absolute)
2 Omega high temperature pressure transducer
Operating pressure: 0-1000 psi (Absolute)
Operating temperature: Up to 232 deg C
PRESSURE SCANNING VALVES
Brand: Scanivalve (USA)
Operating pressure: 0-750 psi
Operating temperature: 0 to 60 deg C