Greystone’s differential and low-pressure transmitters give HVAC and building-management systems the accurate pressure feedback needed for airflow control, filter monitoring, and equipment protection. In India, Airmep Sales Corporation supplies genuine Greystone products with local technical support for commercial, industrial, and data-centre HVAC projects.
Differential pressure is the difference between two pressure points—for example, across an air filter, fan, duct section, or room boundary. Measuring it helps operators confirm that air is moving as designed, detect clogged filters, maintain room pressurisation, and optimise fan energy use. Greystone has manufactured HVAC sensors and transmitters for building and energy-management systems for more than 40 years.
The LP series measures positive, negative, or differential pressure in air or clean inert gases, while the DP series is intended for higher-pressure differential applications using dual remote sensors.
The LPB04X is a versatile low-pressure transmitter for HVAC installations that need field-configurable pressure ranges and output signals. Its jumper-selectable outputs simplify integration with different building automation systems, while the hinged polycarbonate weatherproof enclosure supports demanding plant-room and outdoor-adjacent installations.
Typical uses include:
Air-filter differential-pressure monitoring.
Fan inlet/outlet pressure measurement.
Duct static-pressure control.
General airflow and ventilation-system diagnostics.
The LP series is specifically used for positive, negative, or differential pressure and is commonly applied to filter differential pressure and VAV systems.
The LPB05X is designed for low-pressure HVAC measurement, with selectable ranges of 500 Pa, 1,000 Pa, and 2,000 Pa. It provides 0–10 VDC, 0–5 VDC, or 4–20 mA signals, making it suitable for both voltage-input and current-loop BAS controllers.
It is especially appropriate for:
Variable-air-volume (VAV) terminal control.
Low-pressure duct static control.
Filter monitoring in air-handling units.
Pressure relationships in cleanrooms, laboratories, and isolation areas.
Because these applications depend on small pressure differences, selecting the correct range is important for resolution and control stability.
The DPB07S15 belongs to Greystone’s DP Series and measures differential pressure up to 10 bar, with selectable ranges of 1, 2, 5, and 10 bar. It includes FT-6 plenum-rated cable with a 1.5 m length and supports unidirectional or bidirectional measurement.
The DP Series uses dual remote sensors and is rated for an overload pressure of twice the maximum full-scale range, with burst pressure five times full scale. Its output is factory calibrated and temperature compensated, which supports dependable start-up accuracy.
Common applications include:
High-pressure air or gas differential measurement.
Fan and blower performance monitoring.
Duct, plenum, and process-air pressure verification.
Applications where remote pressure sensing and durable cabling are required.
The GPB07S15 is a gauge-pressure transmitter rather than a true differential-pressure device. It measures pressure relative to atmospheric pressure and offers selectable 4–20 mA, 0–5 VDC, or 0–10 VDC outputs for straightforward BAS integration.
Use it where the requirement is to monitor a single pressure point, such as:
Supply-air duct pressure.
Compressed-air or pneumatic systems.
Fan discharge pressure.
Equipment inlet or outlet pressure monitoring.
For filter condition or room-to-room pressure control, a differential model such as the LPB04X, LPB05X, or DPB07S15 is generally the better choice.
Air-handling units: Use LPB04X or LPB05X across filters to identify loading and schedule maintenance before airflow drops.
VAV systems: Use LPB05X for low-range duct static-pressure control, helping maintain comfort while reducing fan energy.
Cleanrooms and hospitals: Use low-pressure differential transmitters to maintain positive or negative pressure relationships between rooms and corridors.
Data centres: Use pressure transmitters to detect abnormal differential pressure in HVAC systems and support reliable thermal management.
Industrial ventilation: Use DPB07S15 where higher-pressure differentials, remote sensors, and robust plenum-rated cabling are required.
Airmep Sales Corporation supplies Greystone HVAC sensors and controls in India and provides technical support for product selection, commissioning, calibration, and troubleshooting. The company positions itself as a trusted channel for genuine Greystone products, helping projects reduce lead-time risk and downtime through local availability and support.
For Indian HVAC contractors, consultants, and facility teams, Airmep can help match the transmitter range, output signal, enclosure, and cable configuration to the specific application—whether the need is a low-range VAV sensor such as the LPB05X or a higher-pressure DPB07S15 installation.
Before ordering, confirm:
Measurement type: differential, gauge, positive, or negative pressure.
Pressure range: choose the smallest range that safely covers expected operating pressure.
Output signal: 4–20 mA, 0–5 VDC, or 0–10 VDC, based on the controller input.
Media: clean air or inert gas for LP models; verify compatibility for higher-pressure DP applications.
Installation environment: enclosure protection, cable type, and plenum-rating requirements.
BAS integration: signal scaling, direction of measurement, and alarm thresholds.
For specification assistance or pricing for LPB04X, LPB05X, DPB07S15, and GPB07S15 in India, contact Airmep Sales Corporation at info@airmep.in or +91-9810220896.