Employers in certain sectors need to ensure employees are provided with adequate respiratory protection, to guard against risks such as dust, particles and chemical fumes. In addition to the provision of suitable respiratory equipment, it is key that a respirator can be fitted effectively so that it can form a good seal and limit an individual’s exposure to hazardous substances.
Due to this, the correct fitting of respirators is an important part of a company’s health and safety procedures. Employers can further enhance their respiratory protection provision by employing staff who have been trained to effectively fit respirators. Mainland Safety run a Train the Fit Tester course which both educates and practically trains people in the fitting of respirators.
Train the Fit Tester (TFT) is a training programme which enables people to undertake qualitative fit testing. It includes information about selecting and fitting masks and also how to appropriately test for respirator fit.
It is based on good respiratory protection practice and CSA Z94.4. Delegates are taught to use the 3M qualitative fit testing equipment to test the fit of both N95 and half face masks.
Following practical training and a successful final assessment delegates are awarded three year certification.
Respirators are frequently used within the workplace to protect workers from breathing in harmful substances. Poorly fitting respirators can cause unfiltered air to leak into the mask.
Employees can undergo regular testing to establish if a specific make and size of respirator is correctly fitted.
Advantages of fit testing for respirators can include:
Improved worker protection: Helps ensure respirators fit correctly and provide the intended protection.
Workplace safety compliance: Supports respiratory protection program requirements under applicable CSA and WorkSafeBC standards.
Reduced exposure risks: Helps identify poorly fitting masks before employees rely on them in hazardous environments.
Better safety awareness: Educates workers about proper respirator selection and use.
Stronger safety programs: Helps employers maintain consistent respiratory protection procedures.
The Mainland Safety Train the Fit Tester course combines theoretical information with practical exercises. Participants learn the important steps involved in conducting qualitative respirator fit tests.
Key learning areas include:
Understand the responsibilities involved in workplace respiratory protection programs. Learn about respiratory hazards, the importance of proper respirator use, and the key elements of an effective safety program.
Learn how to identify suitable respirators for different workplace situations. Participants also explore the differences between filters and cartridges and understand why selecting the correct respirator model and size matters.
A proper seal is essential for effective respirator protection. Participants learn how to put on respirators correctly and perform seal checks before use.
Learn how to conduct qualitative fit testing using the 3M fit test kit. The process uses harmless sweet Saccharin or bitter Bitrex test solutions to determine whether a respirator provides an acceptable seal.
Understand proper respirator care, cleaning, maintenance, and storage procedures. Participants also learn about maintaining fit-testing records and documentation.
Qualitative fit testing determines whether a respirator provides an acceptable seal by checking whether the wearer can detect a test solution while performing specific movements.
The testing process generally includes the following steps:
Mask Selection: Choose a suitable respirator model and size for the participant.
Donning and Seal Check: Put on the respirator correctly and perform a seal check.
Sensitivity Test: Confirm that the participant can detect the test solution.
Fit Test Exercises: Perform normal breathing, deep breathing, head movements, talking, and bending or jogging in place while wearing the respirator inside a testing hood.
Result Assessment: If the participant detects the test solution during the test, the respirator fails. A different model or size should be selected and tested.
This practical approach helps participants understand how to perform fit testing accurately and consistently.
This training is useful for individuals and workplace safety professionals responsible for respiratory protection and employee safety.
It may be particularly beneficial for:
Occupational health and safety officers
Workplace safety coordinators
Construction supervisors
Industrial safety professionals
Manufacturing facility safety teams
Respiratory protection program administrators
Employers managing employees who use N95 or half-face respirators
Organizations that regularly require employees to wear respirators can benefit from having trained personnel who understand fit-testing procedures.
The Train the Fit Tester course at Mainland Safety is a four-hour, hands-on training program.
Here are the important course details:
Course Name: Train the Fit Tester (TFT)
Duration: 4 hours
Training Type: In-person practical training
Fit Testing Method: Qualitative Respirator Fit Testing
Equipment: 3M Qualitative Fit Test Kit
Prerequisites: No formal prerequisites
Examination: Practical demonstration and final examination
Certification Validity: Three years
Course Fee: $199 + GST
Participants must demonstrate the correct fit-testing procedure and successfully pass the final examination to receive certification.
Selecting the right training provider is important when developing workplace safety knowledge. Mainland Safety offers practical safety training designed to help individuals and organizations improve their workplace preparedness.
Reasons to choose Mainland Safety include:
Experienced and knowledgeable instructors
Hands-on training with practical demonstrations
Focus on applicable respiratory protection standards
Training using the 3M qualitative fit testing kit
Convenient training location in Burnaby, BC
Certification following successful course completion
Whether you are an individual safety professional or an employer looking to strengthen your workplace respiratory protection program, this course can help develop essential fit-testing knowledge.
Correct respirator fit is a key area within health and safety. Qualitative fit testing can be used to further enhance a business’ safety and ensure that they are following regulations, in addition to improving their respiratory protection processes.
To build your respirator fit testing knowledge, why not attend Mainland Safety’s Train the Fit Tester course?
Visit the Train the Fit Tester Course page to explore course details and upcoming schedules.
Contact Mainland Safety:
Phone: +1-604-617-0211
Email: info@mainlandsafety.ca
Training Location: 3236 Beta Avenue, Burnaby, BC, Canada
Take the next step towards better workplace respiratory protection with professional Train the Fit Tester training.