Linux‎ > ‎

Aware Electronics RM-60

I modified Rickard E. Faith (faith@alephnull.com) program code to work with USB-To-Serial adapters. I also wrote daemon and wrapper scripts. Below is a link  to compressed tar file. Once configure.bsh script is run and executable is build and wrapper sripts are deployed RM-60 daemon will start every time when you boot your PC. Radiation level will be logged every 60 seconds to /usr/share/geiger-data/YYYYMMDD.txt file. If level is above of configurable threshold pop-up notification window will be displayed on desktop, terminals will also get console warning message.
ċ
rm60.tar.gz
(5k)
Vadim Tsozik,
Dec 26, 2010, 7:38 PM
ċ
rm60v2.tgz
(6k)
Vadim Tsozik,
Mar 17, 2015, 10:05 AM