Journal Papers:
- C.S. Hu, Y.F. Chung, C.C. Yeh, and C.H. Luo, 「Temporal and spatial properties of arterial pulsation measurement using pressure sensor array,」 Evidence-based Complementary and Alternative Medicine, DOI:10.1155/2012/745127. (SCI, 2011 IF=4.774, 1/22). 此篇談論應用陣列感測器於脈診量化研究的可行性。為首次應用陣列感測器於臨床取樣實驗。
- C. H. Luo, Y. F. Chung, C. S. Hu, C. C. Yeh, X. C. Si, D. H. Feng, Y. C. Lee, S. I. Huang, S. M. Yeh, and C. H. Liang, 「Possibility of Quantifying TCM Finger-Reading Sensations: I. Bi-Sensing Pulse Diagnosis Instrument,」 European Journal of Integrative Medicine, vol. 4, no. 3, pp. e255-e262, 2012. (SCI, 2011 IF=0.775, 17/22). 此篇談論雙感測脈診儀的設計。此脈診儀可重複醫生的取脈深度,並可經由PVDF取得脈象訊息。
- Y.F. Chung, C.S. Hu, C.H. Luo, C. C. Yeh, X. C. Si, D. H. Feng, S. M. Yeh, and C. H. Liang, 「Possibility of Quantifying TCM Finger-Reading Sensations: II. An Example of Health Standardization,」 European Journal of Integrative Medicine, vol. 4, no. 3, pp. e263-e270, 2012. (SCI, 2011 IF=0.775, 17/22). 此篇應用雙感測脈診儀於浮寸中關沉尺的檢驗。
- C.H. Luo, Y.F. Chung, C.C. Yeh, X.C. Si, C.C. Chang, C.S. Hu, and Y.W. Chu, 「Stringlike Pulse Quantification Study by Pulse Wave in 3D Pulse Mapping,」 The Journal of Alternative and Complementary Medicine: Research on Paradigm, Practice, and Policy, vol. 18, no. 10, pp. 924-931, 2012. (SCI, 2011 IF=1.585, 10/22). 此篇經由脈像三維圖譜(3DPM)提出PPW與dPW的方法應用在高血壓弦脈、春弦與非弦脈的辨識。
- Y.F. Chung, C.S. Hu, C.C. Yeh, and C.H. Luo, 「How to Standardize the Pulse Taking Method of Traditional Chinese Medicine Pulse Diagnosis,」 Computers in Biology and Medicine, vol. 43, no. 4, pp. 342-349, 2013. (SCI, 2011 IF=1.089, 56/99). 此篇討論單按取脈與總按取脈法分別在浮中沉與脈搏波最大值時的差異性。
- Yu-Wen Chu, Ching-Hsing Luo, Yu-Feng Chung, Chung-Shing Hu, Cheng-Chang Yeh, 「Using an array sensor to determine differences in pulse diagnosis-Three positions and nine indicators,」 European Journal of Integrative Medicine, 2014. (SCI, 2011 IF=0.775, 17/22).
- Cheng-Ying Chung, Yu-Wei Cheng, Yu-Feng Chung, Ching-Hsing Luo, 「Neural network study for standardizing pulse-taking depth by the width of artery,」 Computers in Biology and Medicine, DOI: http://dx.doi.org/10.1016/j.compbiomed.2014.10.016. (SCI, 2011 IF=1.089, 56/99).
Conference Papers:
- Y.F. Chung, C.S. Hu, Y.W. Chu, C.H. Luo, C.C. Yeh, and X.C. Si. 「Exploring the Conventional Pulse Conditions Using Bi-Sensing Pulse Diagnosis Instrument,」 in 2011 4th International Conference on Biomedical Engineering and Informatics, 2011, pp. 746-750. (EI).
- C.S. Hu, Y.F. Chung, C.H. Luo, C.C. Yeh, and X.C. Si. 「Pulse Difference and 3D Pulse Mapping in TPNI Displacements,」 in 2011 4th International Conference on Biomedical Engineering and Informatics, 2011, pp. 830-834. (EI).
- Y.W. Chu, Y.F. Chung, C.S. Hu, C.H. Luo, C.C. Yeh, and X.C. Si. 「The Wrist Fixer System of Three Position and Nine Indicators Pulse Diagnosis Instrument,」 in 2011 4th International Conference on Biomedical Engineering and Informatics, 2011, pp. 1199-1202. (EI).
- Y.W. Chu, Y.F. Chung, C.S. Hu, C.H. Luo, C.C. Yeh, and X.C. Si. 「Using the Chinese Zither Strings to Simulate the String-Like Pulse of Traditional Chinese Medicine,」 in 2012 5th International Conference on Biomedical Engineering and Informatics, 2012, pp. 482-485. (EI).
- Y.F. Chung, Y.W. Chu, C.Y. Chung, C.S. Hu, C.H. Luo, and C.C. Yeh. 「New Vision of the Pulse Conditions Using Bi-Sensing Pulse Diagnosis Instrument,」 in 2013 1st International Conference on Orange Technologies, 2013, pp. 5-8.
- Y.W. Chu, Y.F. Chung, C.Y. Chung, C.S. Hu, C.H. Luo, C.C. Yeh, and X.C. Si. 「A New Pulse Pillow of Traditional Chinese Medicine – The Wrist Fixer System,」 in 2013 1st International Conference on Orange Technologies, 2013, pp. 11-14.
- C.Y. Chung, Y.F. Chung, Y.W. Chu, and C.H. Luo. 「Spatial Feature Extraction from Wrist Pulse Signals,」 in 2013 1st International Conference on Orange Technologies, 2013, pp. 1-4.