MAKE - JANUS
MODEL - 750 SERIES
DIMENSIONS - MAX 10'-0" X 10'-0"
COLOR - AG GALVALUME, ULTRA MARINE BLUE
FINISH - HIGH GLOSS
ENERGY RATING - (REFER TO PLANS FOR ENERGY CODE REQUIREMENTS)
KEYWORDS - ROLL UP DOOR, DOORS, EXTERIOR DOORS, DRIVE-UP DOORS
MAKE - JANUS
MODEL - 650 SERIES
DIMENSIONS - MAX 10'-0" X 10'-0"
COLOR - HIGH GLOSS WHITE
FINISH - HIGH GLOSS
KEYWORDS - ROLL UP DOOR, DOORS, INTERIOR DOORS, STORAGE DOORS
GENERAL NOTES
NON - FUNCTIONING "DOOR" TYPICALLY LOCATED IN THE "DISPLAY AREA" (REFER TO PLANS)
MAKE - JANUS
MODEL -
DIMENSIONS -
COLOR - ULTRA MARINE BLUE
FINISH - HIGH GLOSS
KEYWORDS - DISPLAY DOORS, BRAND DOORS
GENERAL NOTES
4'-8" FROM FACE OF PIER TO FACE OF PIER
REFER TO DIAGRAMS FOR LAYOUT
GENERAL NOTES
COORDINATE FIRE AND LIFE SAFETY. FIRE SPRINKLER COVERAGE REQUIRED, CONFIRM WITH LOCAL FIRE OFFICIAL FOR CLEARENCES
ALL UNITS TO RECIEVE MESH CEILINGS AND / OR "BURGLAR BARS"
COORDINATE LIGHTING AND MEP ABOVE UNITS
GENERAL NOTES
ALL UNITS 150 SF AND OVER REQUIRE A "UNIT LIGHT"
REFER TO PLANS FOR HALLWAY LIGHTING
MAKE - JANUS
MODEL - JBI CTS (padlock and cylinder accepted)
COLOR - YELLOW ZINC
FINISH - YELLOW ZINC FACTORY
KEYWORDS - DOOR HARDWARE, LATCH, CYLINDER, OVERLOCK
MAKE - JANUS
MODEL - JBI-CTS
PART - JBTS YELLOW ZINC WITH PADLOCK HOLES
DIMENSIONS -
COLOR - YELLOW ZINC
FINISH -
INSTALLATION HEIGHT -
VENDOR NAME - SETH POWELL
VENDOR CONTACT - SETHP@JANUSINTL.COM
MAKE - JANUS
MODEL - JBI-NHYZ-CTS
PART - JBTS YELLOW ZINC WITHOUT PADLOCK HOLES
DIMENSIONS -
COLOR - YELLOW ZINC
FINISH -
INSTALLATION HEIGHT -
VENDOR NAME - SETH POWELL
VENDOR CONTACT - SETHP@JANUSINTL.COM
MAKE - CHATEAU
MODEL - C-487B-4-BK-SGL
PART -
DIMENSIONS -
COLOR - ZINC
FINISH - E COAT
INSTALLATION HEIGHT -
VENDOR NAME -
VENDOR CONTACT -
ADD - DIAMOND PLATE, KICKERS, WALL COVERING, FIRE EXTINGUISHERS,
RECESSED EXTINGUISHER
HVAC UNITS: NOT TO BE MOUNTED ABOVE CUSTOMER UNIT DRIP PAN PROPERLY DRAINED, GRAVITY CONDENSATE LINES NOT PENETRATE STORAGE UNITS, ACCESS PANEL TO BE LOCATED FOR EASE OF MAINTENANCE, 110 AC OUTLETS DISCREETLY MOUNTED 8"-0" A.F.F, T-STAT MOUNTED 8"-0" A.F.F, T-STAT LOCKED & PROTECTED
LIGHTING: CENTERED ON UNIT DOORS (10"-0" O.C.), REFER TO LIGHTING SECTION
CONVENIENCE OUTLETS: MOUNTED ABOVE 8' A.F.Fa DISCREETLY PLACED. IF MOUNTED BELOW 8'-0"- PROPERLY SECURED IN LOCK BOX
UNIT NUMBERS / PLAQUES: CONTACT AMGRAPH
HARDWARE
FIRE PROTECTION
FLOORS: ALL HALLWAYS TO RECEIVE NOX-CRETE 2 PART DENSIFIER OR WAX, INTERIOR UNITS WILL NOT BE FINISHED
DUCTWORK: ALIGNED ON EDGE OF HALLWAY, COORDINATE WITH LIGHTING HEIGHT AND FIRE PROTECTION