NOZZLE ASSEMBLY
Includes the Argon Halo, Manifold, and Tool Interface
NOZZLE FINAL DESIGN
Consists of extended argon halo nozzles which interface directly with the manifold.
Top of nozzle design, where manifold and argon halo interface. The fume extractor barb is also show which connects directly to fluidic loop.
Argon halo design shown with diverging outlet design to reduce flow speeds. The fume extractor inlet is shown, where fumes form the print bed and recirculated argon inlet are extracted.
NOZZLE ITERATION 2
Second nozzle design included argon halos and diverging outlets for fresh argon.
NOZZLE ITERATION 1
Simple converging-diverging nozzle design provided by sponsors.
FLUIDICS LOOP
The diagram to the left demonstrates the motion of different fluids: fresh argon, recirculated argon, and fluid exchange at the bottom of the nozzle.
Circuit Diagram
Mass Diffusion with Enclosure
Mass Diffusion without Enclosure
Mass Diffusion without Enclosure
Mass Diffusion Side View
Gantry Movement
System Design
CAD Gantry with Nozzle Assembly