Inventory
Electronics boards/parts
ICs
LM111: 4
analog comparator
AD652: 3
voltage to frequench converter
frequency to voltage converter
application notes
LM340: 5
linear voltage regulator
NE555: 7
OP27: 10
AD8065ARZ: 3
AD8066ARZ: 3
AD7747ARUZ : 3
ADG794BRQZ: 2
uA741CN:15 units
Summing amplifiers
Voltage followers
Integrators
Active filters
Function generators
LM741:0 units
Comparators
Multivibrators
DC Amplifiers
Summing Amplifiers
Integrator or Differentiators
Active Filter
HA17741:17 units
multivibrator
Sine Wave Oscillator
Quadrature Oscillator
Triangular Wave Generator
Sawtooth Waveform Generator
AD623: 14 units
Bridge Amplifier
Low power medical instrumentation
Transducer interfaces
Thermocouple amplifiers
Industrial process controls
Difference amplifiers
Low power data acquisition
LM324N: 20 units
Bridge Current Amplifier
Transducer Amplifiers
DC Gain Blocks
RC Active Bandpass Filter
LED Driver
Power amplifier
Fixed Current Sources
Voltage Follower
Driving TTL
Pulse Generator
Squarewave Oscillator
High Compliance Current Sink
Low Drift Peak Detector
Comparator With Hysteresis
Voltage Controlled Oscillator Circuit
Ground Referencing a Differential Input
Low-Pass RC Active Filter Signal
Photo Voltaic-Cell Amplifier
AC Coupled Inverting Amplifier
AC Coupled Non-Inverting Amplifier
High Input Z, DC Differential Amplifier
High Input Z Adjustable-Gain DC Instrumentation Amplifier
AD620: 11 unit
Bridge Amplifier
Weigh scales
ECG and medical instrumentation
Transducer interface
Data acquisition systems
msop16 (0.5mm) to dip16 (2.54mm) PCB : 10
無鉛 so/msop/tssop/soic/sop8轉dip8 寬體 窄體 轉接板PCB 8pin: 10
Evaluation boards
Arduino nano v3.0: 2
Arduino mega: 1
Arduino uno: 1
16-channel analog multiplexer (MUX, CD74HC4067): 0
The analog voltages were read via the analog-digital converting pins in the Arduino Nano Microcontroller. We connected a load resistor of 100 MΩ to each sensor and applied an offset of 3.3 V to measure the analog voltage output in the positive value region. The sampling rate was 300 Hz. A personal computer (PC) used for data processing was connected to the microcontroller through serial communication. For the full testing of the 2 × 2 sensor array, a 16-channel analog multiplexer (MUX, CD74HC4067) was used to measure 12 signals and was controlled via the microcontroller. The sampling rate was adjusted to 50 Hz since the number of sensors increased.
A4988 step motor controller: 3
cnc shield v4: 2
MG995 servo motor: 1
Strain gauge amplifier: 1
160603904
廣華電子商城
Power supply DC: 5V
Output accuracy 0.001V
The output voltage is -4 to +4V depending on forward bend and reverse bend.
magnification is fixed at 2500
output zero position is adjustable.
Size: 50.5X30.5 (mm)
Strain gauge BX120-3AA 120 ohm: 15 gauge factor 2.06 ~ 2.12
gauge factor source: https://www.aliexpress.us/item/2251832101378575.html?gatewayAdapt=glo2usa4itemAdapt