Energy Research Lab
Advanced Laboratory for Sustainable Energy and Environment
Dr. Adnan developed a lab for the synthesis of materials for Sustainable Energy and Environment; where some basic instrument have been installed are given below:
Vacuum Glove Box
TORUN 2GBS
Specifications
Main Chamber Size (Approximately): L1200 × W750 × H900
Antechamber size (App.)
-Large Antechamber: DN370 × 600 mm
-Small Antechamber: DN150 × 300mm
Material: Stainless steel (US 304;) with 2 Pairs of Butyl rubber (USA) gloves
Gases: Gases Argon and Nitrogen gas can be used
Control Touch Screen Panel and Install with Gas Purification Column, Oxygen Sensor, Moisture Sensor, and Vacuum pump
Electrochemical Work Station
Corrtest Instruments CS310 CHINA
Specifications
Support 2-, 3- or 4-electrode system
Potential and current range: Automatic
Potential control range: ±10V
Current control range: ±2A
Potential control accuracy: 0.1%×full range±1mV
Current control accuracy: 0.1%×full range
Potential resolution: 10μV (>100Hz),3μV (<10Hz)
Current sensitivity:1pA
Rise time: <1μS (<10mA), <10μS (<2A)
Reference electrode input impedance:1012Ω||20pF
Current range: 2nA~2A, 10 ranges
Compliance voltage: ±21V
Maximum current output: 2A
CV and LSV scan rate: 0.001mV~10,000V/s
CA and CC pulse width: 0.0001~65,000s
Current increment during scan: 1mA@1A/ms
Potential increment during scan: 0.076mV@1V/ms
SWV frequency: 0.001~100 kHz
DPV and NPV pulse width: 0.0001~1000s
AD data acquisition:16bit@1 MHz,20bit@1 kHz
DA Resolution:16bit, setup time:1μs
Minimum potential increment in CV: 0.075mV
IMP frequency: 10μHz~1MHz
Low-pass filters: covering 8-decade
Operating System: Windows 7/8/10/11
Interface: USB 2.0
Weight / Measurements: 6.5kg, 36.5 x 30.5 x16 cm
EIS (Electrochemical Impedance Spectroscopy)
Signal generator
Frequency range:10μHz~1MHz
AC amplitude: 0.1mV~2500mV
DC Bias: -10~+10V
Output impedance: 50Ω
Waveform: sine wave, triangular wave and square wave
Wave distortion: <1%
Scanning mode: logarithmic/linear, increase/decrease
Signal analyzer
Integral time: minimum:10ms or the longest time of a cycle: Maximum:106 cycles or 105s, Measurement delay: 0~105s
DC offset compensation
Potential automatic compensation range: -10V~+10V
Current compensation range: -1A~+1A
Bandwidth: 8-decade frequency range, automatic and manual setting
Batteries Testing Machine
CHINA
Specifications
§ Channel: Multichannel
§ Voltage range: (-5) to 5 V
§ Current range: Below or equal to 10 mA and if above 50 mA will be prefered.
§ 10mA/20mA/50mA
§ Measurement Resolution: 24-bit (1 part in 16,777,216)
§ Ventilation Method: Air-cooled with variable speed fans
§ Data Logging Rate: 2000 points per second, per system
§ Connection for PC: TCP/IP (Ethernet)
§ Independent high precision test channels with full potentiostatic, galvanostatic control
Button Coin Cell Crimping Machine (Manual)
TOB-VCF-150 CHINA
Specifications
· Crimping die: Can die various types of coin cells such as CR2032, CR2025, CR2016, CR2325, CR2450, AG3, AG5 and other special size cases with optional
die sets
· Disassembling die: For all above
· Press die
· Built-in pressure gauge, disassembling pressure adjustable
· Small size in order can be used in glove box
Manual Coin Cell Electrode Disc Cutting Machine
TOB-CP60 CHINA
Specifications
Punching size: φ14mm punching die, φ8-24mm can be chose
For making CR2016, CR2025 or/and CR2032 coin cell batteries, we will need at least three cutting dies:
A 15mm
B 16mm
C 19 mm (for separator to fully separate the electrodes)
· For CR2450 coin cell:
20mm cutting die can be used for cutting electrode discs and the
23mm cutting die for separator disc.
And cutting dies for AG3 and AG5
Oven
MEMERT GERMANY
Specifications
Heat upto 250 C
Muffle Furnace
Lahore Made
Specifications
operate upto 1200 C