Energy Research Lab

Advanced Laboratory for Sustainable Energy and Environment

Dr. Adnan developed a lab for the synthesis of materials for Sustainable Energy and Environment; where some basic instrument have been installed are given below:

Vacuum Glove Box

TORUN 2GBS

Specifications

Main Chamber Size (Approximately): L1200 × W750 × H900

Antechamber size (App.)

-Large Antechamber: DN370 × 600 mm

-Small Antechamber: DN150 × 300mm

Material: Stainless steel (US 304;) with 2 Pairs of Butyl rubber (USA) gloves

Gases: Gases Argon and Nitrogen gas can be used

Control Touch Screen Panel and Install with Gas Purification Column, Oxygen Sensor, Moisture Sensor, and Vacuum pump

Electrochemical Work Station

Corrtest Instruments CS310 CHINA

Specifications

Support 2-, 3- or 4-electrode system

Potential and current range: Automatic

Potential control range: ±10V

Current control range: ±2A

Potential control accuracy: 0.1%×full range±1mV

Current control accuracy: 0.1%×full range

Potential resolution: 10μV (>100Hz),3μV (<10Hz)

Current sensitivity:1pA

Rise time: <1μS (<10mA), <10μS (<2A)

Reference electrode input impedance:1012Ω||20pF

Current range: 2nA~2A, 10 ranges

Compliance voltage: ±21V

Maximum current output: 2A

CV and LSV scan rate: 0.001mV~10,000V/s

CA and CC pulse width: 0.0001~65,000s

Current increment during scan: 1mA@1A/ms

Potential increment during scan: 0.076mV@1V/ms

SWV frequency: 0.001~100 kHz

DPV and NPV pulse width: 0.0001~1000s

AD data acquisition:16bit@1 MHz,20bit@1 kHz

DA Resolution:16bit, setup time:1μs

Minimum potential increment in CV: 0.075mV

IMP frequency: 10μHz~1MHz

Low-pass filters: covering 8-decade

Operating System: Windows 7/8/10/11

 Interface: USB 2.0

Weight / Measurements: 6.5kg, 36.5 x 30.5 x16 cm

EIS (Electrochemical Impedance Spectroscopy)

Signal generator

Frequency range:10μHz~1MHz

AC amplitude: 0.1mV~2500mV

DC Bias: -10~+10V

Output impedance: 50Ω

Waveform: sine wave, triangular wave and square wave

Wave distortion: <1%

Scanning mode: logarithmic/linear, increase/decrease

Signal analyzer

Integral time: minimum:10ms or the longest time of a  cycle: Maximum:106 cycles or 105s, Measurement delay: 0~105s

DC offset compensation

Potential automatic compensation range: -10V~+10V

Current compensation range: -1A~+1A

Bandwidth: 8-decade frequency range, automatic and manual setting

Batteries Testing Machine

CHINA

Specifications


§  Channel: Multichannel 

§  Voltage range: (-5) to 5 V

§  Current range: Below or equal to 10 mA and if above 50 mA will be prefered.

§  10mA/20mA/50mA

§  Measurement Resolution: 24-bit (1 part in 16,777,216)

§  Ventilation Method: Air-cooled with variable speed fans

§  Data Logging Rate: 2000 points per second, per system

§  Connection for PC: TCP/IP (Ethernet)

§  Independent high precision test channels with full potentiostatic, galvanostatic control


Button Coin Cell Crimping Machine (Manual)

TOB-VCF-150 CHINA

Specifications


·         Crimping die: Can die various types of coin cells such as CR2032, CR2025,   CR2016, CR2325, CR2450, AG3, AG5 and other special size cases with optional  

           die sets

·         Disassembling die: For all above

·         Press die

·         Built-in pressure gauge, disassembling pressure adjustable

·         Small size in order can be used in glove box


Manual Coin Cell Electrode Disc Cutting Machine

TOB-CP60 CHINA

Specifications



A 15mm

B 16mm 

C 19 mm (for separator to fully separate the electrodes) 

·         For CR2450 coin cell:


Oven

MEMERT GERMANY

Specifications


Heat upto 250 C

Muffle Furnace

Lahore Made

Specifications


operate upto 1200 C