Transurethral Resection of Prostate (TURP)
Quick Reference
-URO HDTV / Theatre 3 TV system
-Olympus USG 400 /
-Karl Storz UH 400
-S204C Olympus Bipolar TURP Set
-U009 Elik Evacuator for TURIS
-S210A Karl Storz Bipolar Set
-U009A Storz Cysto-Evacuator
-Camera Head x 1
-SURG0995 Wolf FOB (For URO TV System)
-UC23 Cystoscope, 4mm/30 (For TURIS), Olympus
-UC26 HOPKINS® II Telescope 30°
Drape:
Lithotomy Drape
Large Drape
-Short gauze
-20mL Syringe
-Electrode Loop :
Olympus WA22306D HF-resection electrode, loop, 24Fr., medium, 30, 0.2 mm wire
Storz 011168-10 Cuttung Loop, bipolar
-Xylocaine Jelly
-TURP set (Y set)
Connect camera head, FOB, NS tubing with cystoscope and white balance
Pass the Xylocaine jelly to surgeon for lubricating the cystoscope
Fill up the ellik with warm normal saline for bladder irrigation
+/- Unfold a short gauze and put it in the sieve on top of a kidney dish in the basin
Receive the ellik from surgeon and rinse the ellik for specimen
Weight the specimen as required and tell the surgeon