Working Line and Bundles

1. Engine stops as directed by Officer

a. At fire

2. Firefighter gets off engine with full PPE

3. Equipment is removed

a. Hose clamp

b. Tri-wye

4. Working line is pulled

a. Quantity as determined by Officer

b. Laid out on the ground behind engine

c. Working line is broken with male end going back in hose bed

d. Additional nozzles are removed if needed

5. Bundle(s) are removed

6. Oasis valve and LDH is removed

7. Firefighter anchors supply

a. With hands

b. Maintains anchor until enough hose is on the ground

8. Firefighter signals Driver

a. To “Take off”

9. Engine lays supply hose

a. To water source

b. Attention is given to hose lay out on street

c. Supply line is clamped

d. Water is called for verbally, visually or by radio

10. Remove Oasis valve from LHD

11. Tri-wye is connected

a. Valves are confirmed closed

b. Water is called for

12. Clamp is removed

13. Working line is connected

a. To Tri-wye

14. Working line and bundle are advanced to fire

15. Set bundle and working line down at objective

a. Remove nozzle from the end of working line

16. Remove bundle bra straps

a. Connect gated wye to working line

b. Shut off wye valve

c. Call for water – verbally, visually or by radio

17. Flake out bundle

a. Call for water – verbally, visually or by radio

18. Charge bundle

a. Open wye

b. Remove kinks

19. Bleed air from nozzle

a. Away from fire