This intelligent FACP comes with a communicator preinstalled which provides support for 198 addressable devices (99 modules and 99 detectors). The NFW-100 X easily installs into applications which previously used only conventional panels with powerful programming features.

The FireWarden-100X (NFW2-100X, NFW2-100XR) is a UL listed addressable fire alarm control panel designed for applications requiring advanced addressable intelligence, flexible programming options, and robust power supply for driving horns, strobes, and auxiliary devices. The FireWarden-100X (NFW-100X) is the latest intelligent addressable Fire Alarm Control Panel (FACP) within the FireWarden Series. The NFW-100X comes with a pre-installed communicator and supports up to 198 addressable devices (99 detectors and 99 modules). With an extensive list of powerful features, the NFW-100X programs just like FireWarden-100 products, yet fits into applications previously served only by conventional panels.


Notifier Nfw-100x Programming Software Download


Download 🔥 https://urloso.com/2y4NS3 🔥



Listed to UL Standard 864, 10th editionPre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Telephone Service) Central Station Communicator over AlarmNetOptional CELL-MOD or CELL-CAB-N GSM Central Station Communicator over AlarmNetAutomated activation of the NFC-50/100 Emergency Command CenterNFC-FFT Firefighter Telephone optionCompatible with SWIFT wireless devicesAuto-programming (learn mode) reduces installation time. Reports two devices set to the same addressFour built-in, independently programmable Style Z (Class A) or Style Y (Class B) NAC circuitsSelectable strobe synchronization for System Sensor, Wheelock, and Gentex devicesNotification Appliance Circuit End of Line resistor matchingFour programmable function keys for ease of maintenanceTwo programmable relays and one fixed trouble relayBuilt-in ProgrammerIntegral 80-character LCD display with backlightingReal-time clock/calendar with automatic daylight savings controlHistory file with 1,000 event capacityAddressable sounder base compatibilityControl module delay timerAutomatic detector sensitivity testing (NFPA 72 compliant)Automatic device type-code verificationPoint trouble identificationWaterflow selection per module pointAlarm verification selection per detector pointMaintenance alert warns when smoke detector dust accumulation is excessiveOne-person audible or silent walk test with walk-test log and printoutSystem alarm verification selection per detector pointPAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant)Up to 16 ANN-BUS annunciators- 8 per each ANN-BusRemote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciatorUpload/Download of program and data via USB with optional FSTools Programming UtilitySLC COMMUNICATION LOOPSupports FlashScan and CLIP protocolsSLC operates up to 10,000 ft. (3,000 m) in FlashScan mode with twisted, unshielded wireSingle addressable SLC loop which meets NFPA Class B and Class A requirements198 addressable device capacity (99 addressable detectors and 99 modules)Compatible with NOTIFIER FireWarden and ONYX Series addressable devices (refer to the FireWarden SLC Wiring Manual)NOTIFICATION APPLIANCE CIRCUITS (NACS)Four independently programmable output circuits. Circuits can be configured for the following outputs:Style Y (Class B)Style Z (Class A)Silence Inhibit and Autosilence timer optionsContinuous, March Time, Temporal, or California code for main circuit board NACs with two-stage capabilitySelectable strobe synchronization per NAC2.5 A special application, 250mA regulated, total power for NACsNOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 APROGRAMMING AND SOFTWAREAutoprogramming (learn mode) reduces installation timeCustom English labels (per point) may be manually entered or selected from an internal library fileTwo programmable Form-C relay outputs99 software zonesContinuous fire protection during online programmingProgram Check automatically catches common errors not linked to any zone or input pointOFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows-based software package, and upload/download system programming locally. Offline programming requires an ethernet connection. FS-Tools is available on www.notifier.com.

NFW-100X: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display chassis with transformer, backbox with door, plastic bag containing screws, cables, key, etc.FS-Tools: Programming software for Windows-based PC computer. Available for download at www.notifier.com.CELL-CAB-N/CELL-MOD: Optional GSM communicators.IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board)DP-ES-R: Optional dress panel for the NFW-100X (red).DP-ES-B: Optional dress panel for NFW-100X (black).TR-CE-B: Optional trim ring for semi-flush mounting. (Black. For red, order TR-CE.)BB-XP: Optional cabinet for one or two modules.BB-25: Optional cabinet for up to six modules mounted on CHS-6 chassis.BB-26: Battery backbox, holds up to two 25 AH batteries and CHG75.NFS-LBB: Battery box, houses two 55 AH batteriesCHS-6: Chassis, mounts up to six multi-modules in a BB-25 cabinet.CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH.CHG-120: Remote battery charging system for lead-acid batteries with a rating of 55 to 120 AH. Requires additional NFS-LBB for mounting.NOTE: CHG-120 or CHG-75 required for batteries larger than 18AH.BAT Series: Batteries, see data sheet DN-6933.PRN Series: UL listed compatible event printer. Uses tractor-fed paper.OPTIONAL MODULES4XTM Reverse Polarity Transmitter Module: Provides a super vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED.PWRMOD24 Power Expander Module: Optional power module. Increases alarm power output to 6 amps.COMPATIBLE ANNUNCIATORSN-ANN-80: Remote LCD annunciator mimics the information displayed on the FACP LCD display. Recommended wire type is unshielded. (Basic model is black; order -W for white; see DN-7114.)N-ANN-100R: Remote LCD annunciator mimics the information displayed on the FACP LCD display. Recommended wire type is unshielded. For use in FM applications only. (Basic model is black; order R for red.)N-ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DN-7105.)N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DN-60242.)N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242.)N-ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DN-7107.)N-ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DN-7103.)ADDRESSABLE DEVICESFSP-951: Addressable low-profile photoelectric smoke detector. FlashScan only.FSP-951-IV: Addressable low-profile photoelectric smoke detector. Ivory. FlashScan and CLIP mode.NP-200: Addressable low-profile photoelectric smoke detector. B300-6 base included, FlashScan only.NP-200-IV: Addressable low-profile photoelectric smoke detector. Ivory, B300-6-IV base included. FlashScan and CLIP mode.FSP-951T: Addressable low-profile photoelectric smoke detector with thermal sensor. FlashScan only.FSP-951T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory. FlashScan and CLIP mode.NP-200T: Addressable low-profile photoelectric smoke detector with thermal sensor. B300-6 base included. FlashScan only.NP-200T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory, B300-6-IV base included. FlashScan and CLIP mode.FSP-951R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only.FSP-951R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. FlashScan and CLIP mode.NP-200R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only.NP-200R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory, FlashScan and CLIP mode.FST-951: Low-profile 135F fixed thermal sensor. FlashScan only.FST-951-IV: Low-profile 135F fixed thermal sensor. Ivory. FlashScan and CLIP mode.NH-200: Low-profile 135F fixed thermal sensor. B300-6 base included, FlashScan only.NH-200-IV: Low-profile 135F fixed thermal sensor. Ivory. B300-6-IV base included, FlashScan and CLIP mode.FST-951R: Low-profile, intelligent, rate-of-rise thermal sensor. FlashScan only.FST-951R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory.FlashScan and CLIP mode.NH-200R: Low-profile 135F fixed thermal sensor. B300-6 base included, FlashScan only.NH-200R-IV: Low-profile 135F fixed thermal sensor. Ivory. B300-6- IV base included, FlashScan and CLIP mode.FST-951H: Low-profile intelligent 190F/88C fixed thermal sensor. FlashScan only.FST-951H-IV: Low-profile intelligent 190F/88C fixed thermal sensor. Ivory. FlashScan and CLIP mode.NH-200H: Low-profile intelligent 190F/88C fixed thermal sensor. B300-6 base included, FlashScan only.NH-200H-IV: Low-profile intelligent 190F/88C fixed thermal sensor. Ivory. B300-6-IV base included, FlashScan and CLIP mode.Legacy DevicesFSI-851: Addressable low-profile ionization smoke detector.NI-100: Addressable low-profile ionization smoke detector.FSP-851: Addressable low-profile photoelectric smoke detector.NP-100: Addressable low-profile photoelectric smoke detector.FSP-851T: Addressable low-profile photoelectric smoke detector with thermal sensor.NP-100T: Addressable low-profile photoelectric smoke detector with thermal sensor.FSP-851R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing.NP-100R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing.FST-851: Fast-response, low-profile heat detector.NH-100: Fast-response, low-profile heat detector.FST-851R: Fast-response, low-profile heat detector with rate-of-rise option.NH-100R: Fast-response, low-profile heat detector with rate-of-rise option.FST-851H: Fast-response, low-profile heat detector that activates at 190F/88C.NH-100H: Fast-response, low-profile heat detector that activates at 190F/88C.FAPT-851: Addressable low-profile multi-sensor detector.NP-A100: Addressable low-profile multi-sensor detector.B200S: Programmable, addressable sounder base.B200SR: Addressable sounder base.DNR: InnovairFlex low-flow non-relay duct-detector housing. (Order FSP-851R, FSP-951R, or NP-100R separately.)DNRW: InnovairFlex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order FSP-851R, FSP-951R, or NP-100R separately.) Addressable ModulesFMM-1: Addressable Monitor Module for one zone of normally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC.NMM-100: Addressable Monitor Module for one zone of normallyopen dry contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC.FDM-1: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only IDCs.NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only IDCs.FMM-101: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox.NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox.FZM-1: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation.NZM-100: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation.FCM-1: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances.NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances.FRM-1: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500.NC-100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500.NBG-12LX: Addressable manual pull station with interface module mounted inside.NOT-BG12LX: Addressable manual pull station with interface module mounted inside.ISO-X: Fault Isolator Module.N100-ISO: Fault Isolator Module.ISO-6: Six-fault isolator module. Mount one or two modules in a BBXP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet.SMB500: Used to mount all modules except the FMM-101/NMM100P.NMM-100-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet.NZM-100-6: Six-zone interface module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet e24fc04721

strong vibration sound download

nimbus sans thai bold font free download

download pemetaan kd matematika kelas 6 semester 1

snakes and ladders game apk download

curl download