[German]A counter in the firmware of certain HPE SSD storage systems may overflow in the coming days, causing data loss and system failure. The manufacturer HPE warns against this scenario and asks device administrators to update the firmware.

In the affected HPE SSD storage media a counter for the operating hours runs in the firmware. In the SSD firmware version installed on the devices, a drive failure and data loss occurs after 32,768 operating hours. This requires a recovery of data from the backup. Using the drives in a fault tolerant RAID mode (e.g. RAID 0) does not protect against data loss, if more drives fail than are supported by the logical drive in the fault tolerant RAID mode. This scenario is likely to cause the SSDs in the RAID array to reach operating hours and fail almost simultaneously.




HPE Warns Of SSD Storage Systems Failure Coming Soon