INSTALLATION SERVICE SYDNEY TO THE HUNTER
Phone : 0491 005237
Madimack V4 Series
Finely engineered design enhancements providing significant advancements in performance and resulting in a world best COP of 22. COP is the industry standard for measuring the efficiency of heat pumps. It represents the relationship between the heat generated and the power used to generate it. Essentially, the higher the COP the more efficient the unit. Triple layered sound insulation, commercial grade centrifugal fan, a revolutionary 3-Directional airflow, premium twin rotary compressor and three internal reflectors have joined forces to make Madimack’s InverELITE V4 the world’s most efficient, quietest, best performing pool heat pump
INVERECO PLUS
POOL HEAT PUMP SERIES
Built with efficiency and simplicity in mind the quiet, long-lasting and easy to use Eco is perfect for energy-conscious minds. With low energy and night time mode, it means efficiency can be increased by up to 20%, and with WiFi as standard, you can change your pool temperature and timers from wherever you are. State of the art anti-corrosion ABS casing means you can be sure your pool stays warm season after season no matter where you live. This electric pool heat pump series is ideal for recreational pool & spa owners.
SENSAPOOL PIX
POOL HEAT PUMP SERIES
The SENSAPOOL PiX Series inverter heat pumps have been specifically designed for pool and spa applications across Australia and New Zealand.
The PiX series heat pumps have been designed with a side discharge fan making them the ideal space saving solution.
Offering the latest and most efficient inverter technology and industry leading ultra quiet operation.
With heater sizes from 11kw up to 40kw, you can be sure to find a heater to suit your pool and spa requirements.
SENSAHEAT Heatpump Relay Box
Isolated Switching Interface
Switched Input: 240VAC
Switched Output: Max 24VAC/1A
Allows on/off control of a Sensaheat Heat Pump via an external controller.
Madimack MJ Box
Madimack Single Pump Controller is designed to operate a filter pump when filtration is called for by either the chlorinator or heater.
Heat Demand
As most pools are filtered for 8 hours a day, extra run times are often required to maintain the water at the desired temperature. The heat pump heater is equipped with a demand function that will assist in maintaining the temperature of the pool. The controller will over-ride the filter pump when heat is called for by the heat pump which monitors the temperature within its defined run times.
Dontek
AQUAHEAT 5 RO -S
The Aquaheat H5RO-S controller is suitable for separate/independent circulation pump systems in combination with ‘Heat Demand’ style of heat pumps.
The H5RO-S Controller is designed to switch on a 240Vac circulation pump, controlled from the ‘HEATER INTERLOCK’ output of the heat pump.
The DT-H5RO-I controller is designed to operate a filter pump when filtration is called for by either the chlorinator or heater.
Heat Demand
As most pools are filtered for 8 hours a day, extra run times are often required to maintain the water at the desired temperature. The heat pump/gas heater is equipped with a ‘Demand Heat” function that will assist in maintaining the temperature of the pool by communicating to the H5R0-I. The controller will over-ride the filter pump when heat is called for by the heat pump which monitors the temperature within its defined run times. By this mean, the user is sure the water is always ready to bathe, day or night.
Inverflow Quick Connect Comms Cable
The Madimack Inverflow Quick Connect Comms Cable is designed to enhance the functionality of your Madimack Pool Pump by providing seamless communication and connectivity to your heatpump
Quickly connects the filter pump to the heat pump for total control
Ideal for stand alone systems
Controls flow no need for valves
Inverflow Pro P300i/P400i
Ideal for stand alone systems
Ideal for stand alone systems
Inverflow Quick Connect Comms Cable
The Madimack Inverflow Quick Connect Comms Cable is designed to enhance the functionality of your Madimack Pool Pump by providing seamless communication and connectivity to your heatpump
Quickly connects the filter pump to the heat pump for total control
Ideal for stand alone systems
Controls flow no need for valves
Astral E170C Pool Pump 3/4 HP
Ideal for stand alone systems
Ideal for stand alone systems
INSTALLATION OPTIONS
MOST POPULAR
1. Chlorinator controller initiates the filtration pump either manually or through a timer.
2. Heat pump’s flow switch senses the water flowing through the heat pump.
3. Heat pump starts and will run until temperature is reached or filtration pump switches off
4. No additional internal wiring to the heat pump is required in this set up
5. No additional settings needed to be changed.
6. If the circulation pump is not running and no flow is detected, the unit will display E3 – this is normal and an indication the unit is sitting idle waiting for the filtration pump to start again.
7. If the pool temperature is not reached within the filtration times you may need to extend the timers to match the heating requirement.
1. Termination socket is labeled (Pump control output) found on the side of the heat pump and connects to P1 – P2 on the on-board relay and is activated by the timers (set on the Heat pump app) and pool temperature.
2. Once temperature is reached or the timer is finished the heat pump will switch off the relay output stopping the circulation pump.
3. If the pool reaches temperature but the timer is still active the heat pump will switch off relay to stop the circulation pump. Whilst the timer is still active every hour it will run the circulation pump for 2 minutes to test the water temperature. If the temperature is 1 degree below set point the heat pump will continue to run the circulation pump and start the heating process again.
4. Pump control socket only to be used with low voltage cable and devices
5. Heat Pump timers are set through the mobile application and requires a Wi-Fi connection. If no Wi-Fi is present, then additional external timer may be required or a Wi-Fi booster to extend a local Wi-Fi network (not supplied)
6. On the single pump controller (MJBOX), connect the black power cable to a 240V GPO, connect the grey piggyback cord into the chlorinator, and plug the water pump into the bottom of the single pump controller (MJBOX). 7. Connect the Fig 8 wire from the single pump controller to the pump control output terminals. (See control socket connection diagram, section [depending on the designer])
1- See Pool Pump installation manual for more information on commissioning and how to set the pump. (pump should be in normally off state for activated control)
2- Termination socket is labeled (Pump control output) found on the side of the heat pump, connected to the quick connect socket that comes with the Inverflow pro and ultra pumps. InverFlow Eco pump cable sold separately (See control socket connection diagram, section [depending on the designer])
3- Once temperature is reached or the timer is finished the heat pump will switch off the relay output stopping the circulation pump.
4- If the pool reaches temperature but the timer is still active the heat pump will switch off the relay to stop the circulation pump. Whilst the timer is still active every hour it will run the circulation pump for 2 minutes to test the water temperature. If the temperature is 1 degree below set point the heat pump will continue to run the circulation pump and start the heating process again.
5- Heat Pump timers are set through the mobile application and require a Wi-Fi connection. If no Wi-Fi is present, then additional external timer may be required or a Wi-Fi booster to extend a local Wi-Fi network (sold separately)
6- Pool pump cannot be adjusted when controlled by heater and will be indicated by Di2 on the controller
1. In may be impractical to get a new power cable from the house switch board to the pool equipment area due to finished flooring etc., in this case It may be possible to use the existing pipework which connects to the house and install a power cable from there.
2. An external thermostat controller can initiate the existing circulation pump, thus running the heat pump through the flow switch for full temperature control. Please speak to your installer for more information.
3. No additional wiring to the heat pump is needed internally
4. Timers are set on the external thermostatic controller
5. Set heat pump to 40 degrees (above the set point temperature of the external temperature controller.)
Automation systems and additional controls
Control input (Slave connection input normally closed): The Madimack heat pump has an external controller input built into the heater. This is to allow for external connections such as automation systems, PV inverter controllers, or external timers. The input is a volt free input and extra should be taken that the device connecting to is a volt free relay. For 230v inputs please see Madimack Automation Bridge (sold separately) for more information. Connecting additional controls 230V auxiliary outputs, please see Madimack automation bridge (sold separately) www.madimack.com.au/brochures The heat pump comes with easy to connect socket labeled as control input The unit comes pre-wired with a bridge cable connected. To add an external control to activate the heat pump, remove the bridge and add in a volt free terminal connection. Please check with the automation system provider that the connection is volt free and the best way to install with their set-up. P The sockets can be found on the right-hand side of the unit, used to simplify the process of connecting control cables from and into the heat pump (Volt free connections only). If these are removed without being connected it may show EXT OFF on the display. lease see control socket connection diagram for further information around connecting to the socket.) If Madimack quick connect is a unique feature found in Madimack products aimed to simplify the installation process. the external controller is not initiating the heat pump to operate the display with show the word “OFF”
Madimack quick connect is a unique feature found in Madimack products aimed to simplify the installation process.
GET THE RIGHT ADVICE
POOL SIZING MATTERS
When it comes to sizing your heatpump get the right advice the first time.We use a comprehensive evaluation sizing system designed and streamlined to generate accurate results.Having an accurate measuring system ensures you get the right product the first time.
DID YOU KNOW -Using a pool blanket will hold up to 45% of your heat over night
DONT BE FOOLED BY SIZING TABLES
HEAT PUMP TIME CALCULATOR / WATER VOLUME CALCULATOR
(GUIDE ONLY)
Ambient water temp is the same as
initial water temp
PLEASE NOTE:
These times will vary depending on atmospheric conditions