CRITERIA
Acceptance criteria for specimens
Nasal swabs collected within 30 minutes and stored in the extraction buffer.
Specimen rejection criteria :
Sample other than nasal swab;
Nasal swab collected more than 1 hour ago;
Swab received in a medium other than the one supplied in the kit;
Kits should be stored between 2 - 30˚C.
Do not use the kits beyond the expiration date;
Do not use cartridges if the packaging is damaged.
The BD VeritorMD device should be stored between 15 - 30°C with a relative ambient humidity of < 85 %, without condensation.
The test should be performed in a dedicated area and at a minimum distance of two meters from other workers and patients.
The BD VeritorMD device should be placed on a flat, dry and stable surface away from direct sunlight or strong light.
Wearing PPE as recommended by the PCI is mandatory.
Samples should be considered potentionally infectious.Viruses are not inactivated.
The work surface must be cleaned and decontaminated before and after the work shift, using a disinfectant wipe.
Waste is disposed of in accordance with the biological waste disposal protocol. The swab, tube and device should be disposed of in a biological waste bag.
The extraction buffer contains < 0,1 % sodium azide as a preservative which may be toxic if swallowed.
Reference
Gouvernement du Canada. Avis de biosécurité. 30 juin 2020. SRAS‑CoV‑2.
LSPQ – INSPQ Le Laboratoire de santé publique du Québec
Auteur : Maud Vallée, PhD
Réviseurs : Vincent Boissonneault, MD, MSc., FRCPC, Marie-Noël Lambert, TM, Michel Roger, MD, PhD, FRCPC, Judith Fafard, MD, FRCPC
Gouvernement du Québec et Gouvernement du Canada
Adapté pour l'ICM par Isabelle Plamondon, TM, Assistante-Chef Qualité et EBMD
Adapté pour Optilab par Denis Savard, TM, Coordonnateur technique Qualité et EBMD
Gouvernement du Canada. Avis de biosécurité. 30 juin 2020. SRAS-CoV-2.
https://www.canada.ca/fr/sante-publique/services/biosecurite-biosurete-laboratoire/directives-avis-avis-speciaux-matiere-biosecurite/nouveau-coronavirus-27-janvier.html
Fournisseur BD
BD Veritor™ System For Rapid Detection of SARS-CoV-2. REF 256089. Monographie du fabricant.
Quick reference guide du fabricant
BD VeritorMD Plus Analyzer. Manuel du fabricant.
https://www.youtube.com/watch?v=Fs4w1J7dslI
BD Veritor Plus System for Rapid Detection of SARS-CoV-2.
https://www.youtube.com/watch?v=_65MZIt48cU