Client: Double check Client/project name
Location: Double check project location (city, state)
Date: proper date (and issue/release name)
Cover sheet: triple check client, location, date
Drawing index — check against drawings (title and number)
Proper @ date
Scale: everything to scale relative to everything else
Caulk/sealant is darker hatch than backer rod and proper shape and size.
Layering clear and properly sequenced.
Flashing darker lineweight than moisture barrier.
Flashing sloped with end dams
Window head flashing extends beyond jamb through vertical trim or to corner (if applies)
Casing at windows properly aligned. Wall trim over jamb.
Vent penetration detail not dryer, verify isometric drawing with small lower fin, no head flashing
High temperature vent penetration detail (Fireplace/water heater/furnace)
Door details (no nailing fin)
No cant strip at deck (so the door sill pan can go straight down)
Stucco joints (horizontal expansion continuous, vertical broken)
Door pan sill 2" min horizontal leg
Show trim at top of siding flat against wall, not against soffit
Table of contents/ index — Check all Sections are included.
Clean before reinstalling miscellaneous fixtures (e.g. light fixtures).
Buildings with flat roofs. Note to re-side anything at roof level.
Cross-referencing — Check all “Related Sections” are included.
Warrantees — defined for related section.
07460 f-c siding Warrantee — number of years (50 adds cost).
07920 caulk Backer rod — should be “soft type which combines the best of closed and open cell.”
07920 caulk Sika has trouble with UV — should be restrict to applications that will not be exposed to UV.
08 Windows — do not ask for installation instructions or details as these are covered in our details and the manufacturer's recommendations may contradict ours.
08 Windows — replacement criteria.
09225 stucco — Drainage mat included, vertical joints shall be broken at horizontal expansion joints.