If your inverter displays any error codes not listed below,
Please contact the Sun King Inverter Customer Care team on +260 971 243 303
Fault Name: Battery Over temperature
Affects Output: Yes
Troubleshooting:
Switch off the battery for 5 minutes then back on.
Enter the code 254123 the error should clear.
If the error persists, Call the Sun King customer support number +260 971 243 303
Fault Name: Overload
Affects Output: Yes
Troubleshooting:
Disconnect all the loads
Switch off the PV breaker > AC breaker > Changeover switch > Inverter > battery in that sequence.
After 5 minutes switch on in reverse sequence starting with the battery > Inverter > Changeover switch > AC breaker > PV breaker
Power your loads one by one to determine the appliance with overload.
Fault Name: Fan Failure
Possible Cause: The inverter cooling fan is blocked, preventing proper ventilation.
Troubleshooting:
Power off the inverter.
Inspect all fan vents and openings.
Remove any dust, debris, or objects blocking airflow.
Ensure the inverter is placed in a well-ventilated area.
Power on the inverter.
Restart the inverter using the reset code 531135
Fault Name: Battery Low
Possible Cause: Battery charge level is too low to support inverter operation.
Troubleshooting:
Leave the inverter powered on.
Allow the battery to recharge using solar or utility input.
Avoid connecting heavy loads during charging.
Check the inverter to see if there is a red blinking light, this means that there is an error experienced by the inverter.
The screen may be off, this means the inverter is in Sleep mode but not off
Press the "Ent" button once and wait for the screen to go on
Check the fault code displayed and refer to the user manual for troubleshooting.
if the there is no user manual contact the Sun King Inverter Customer Care team on +260 971 243 303
Inverter Has No Error but No AC Output
Ensure the inverter is powered ON.
Locate the power button and turn the inverter OFF.
Wait 10–15 seconds.
Turn the inverter ON again.
When prompted, enter the reboot/reset code 531135
Allow the inverter to complete the reboot process.
Turn off the PV breaker and the AC breaker in the Sun King protection box.
Turn off the inverter by flipping the switch on the right underside part of the inverter.
Wait for 1 minute until the inverter is completely off.
Proceed to the battery, press and hold the power button for at least 2 seconds and release. This will cause the battery display to go into sleep mode until it turns off completely.
Wait for 5 minutes for the battery to reset and then turn on the battery again.
Then turn on the inverter and after 2 minutes lift the PV and AC breakers in the Sun King protection box.
If the issue persists please call the Sun King Inverter Customer Care team on +260 971 243 303
Press the "Set " button on the inverter. This will display "00ESC" which switches the inverter to setting mode.
Press the "Up" button which will lead to setting "01" and press enter. This will cause the words on the right side of the display to blink until an action is performed.
Press the "Up" until you come to option "UTI." This means the inverter has been configured to prioritize ZESCO as the source power.
Press the "Set" button again which will take you back to the main screen where you will see the word "BYPASS" and a dotted line leading to the percentage bar on the right side of the display which signifies how much of the battery is being used.
If the issue persists please call the Sun King Inverter Customer Care team on +260 971 243 303
Press the "Set " button on the inverter. This will display "00ESC" which switches the inverter to setting mode.
Press the "Up" button which will lead to setting "06" and press enter. This will cause the words on the right side of the display to blink until an action is performed.
Press the "Up" until you come to option "CUB." This means the inverter has been configured such that ZESCO can charge the battery even when solar is available.
Press the "Set" button again which will take you back to the main screen where green light will blink provided the battery is not fully charged. (when fully charged the light is idle/ does not blink)
This is not energy saving.
If you prefer the energy saving options repeat the first 2 steps and select the "SNU" option. which means solar and utility will charge at the same time.
Press the "Set" button again which will take you back to the main screen where an icon for the solar panel and utility are connected by dotted lines and leading to the percentage bar.
If the issue persists please call the Sun King Inverter Customer Care team on +260 971 243 303
Possible Cause:
The inverter is configured to prioritize utility (grid) power instead of solar and battery power. Common incorrect modes include UTI (Utility) or SNU (Solar and Utility).
To reduce grid usage, the inverter must be set to:
SBU (Solar → Battery → Utility) for load priority
OSO (Only Solar) for charging priority
Press the SET button to enter Setting Mode.
Press the UP button to scroll to Setting 01.
Press ENTER. The current mode (for example, UTI) will start blinking.
Press UP or DOWN until SBU appears on the screen.
Press ENTER to confirm.
Press SET to exit Setting Mode.
This ensures the inverter uses solar first, then battery, and only uses utility power when necessary.
Press the SET button to enter Setting Mode.
Press the UP button to scroll to Setting 06.
Press ENTER. The current mode (for example, SNU) will start blinking.
Press UP or DOWN until OSO appears on the screen.
Press ENTER to confirm.
Press SET to exit Setting Mode.
This ensures the battery is charged only from solar, not from utility power.
Confirm solar panels are generating power during daylight hours.
Check that batteries are connected and functioning.
Contact the Sun King Inverter Customer Care team on +260 971 243 303