Finnleo SCA-60V Sauna Heaters

Only available in 6kW



PayPal Simple Storefront

Electrical Specification

This heater can be connected to either 230V, 50Hz single-phase, or 400V, 50Hz 3-phase supplies.

 

They should be installed by a qualified person and in a domestic property all wiring should comply with BS7671, IET Wiring Regulations 17th Edition and The Building Regulations 2000, Part P.

 

Sauna heaters can sometimes trip residual current devices (RCDs). BS7671, Regulation 703.411.3.3 (page 179 BS7671, 2008) allows these heaters to be connected to NON-RCD circuits.


The single-phase 230V circuit needs to be protected by a 30/32 fuse or Type B circuit breaker to BSEN60898.

 The 3-phase 400V circuit needs to be protected by a 3 x 10Amp fuses or a triple-pole 10Amp Type B circuit breaker to BSEN60898.

 RCBO's to BSEN 61009-1 can be used