Learned fluorescent magnetic particle inspection (MPI) to detect cracks on forged transmission components
Performed dimensional inspection of finished shafts against engineering drawings
Applied fluorescent magnetic solution and inspected parts under UV light, where crack indications glow due to magnetic flux leakage
Flagged forged shafts showing crack indications before further processing
Measured critical dimensions with a height gauge and cross-checked against GD&T callouts on the drawing
Gained hands-on exposure to NDT crack-detection methods used in OEM quality control
Helped prevent defective forged parts from advancing in production
Practiced linking dimensional measurements to GD&T requirements on real production drawings