CODEUDESCRIPTIONQUANTITYPRICE (€)Amount (€)IMPACT OF LABOR (€)MANPOWER (H)IMPACT OF LABOR (%)
RE0587u

Measurement and control of movement in cracks, joints, etc. (10 IU)

1,00494,31494,31273,0011,5055,23
Campaign measurement, control and monitoring of movements vertical, horizontal and rotational fissures, cracks, expansion joints, decks or surfaces, or local building inspection with 10 units, consisting of the installation of fissurímetres 2 directions record quarterly readings for a year and making a record will be documented on the location and photograph of each record, regular readings and conclusions or recommendations without prior expert character. Includes: fissurímetres of two directions (two devices per inspection unit, approximately) with resolution 0.1 mm and 2.5 cm range, manufactured in polyester weatherproof, tours and travel. Not included: writing report or expert opinion or auxiliary means for heights exceeding 3 m or restitution coatings.
%01a%Ancillary costs of labor0,021,50
%02%indirect costs0,037,65
Estimating the degree of difficulty or uncertainty (normal 1.00)1,00
MOU0068hSpecialist higher. Professional Level II (Source: IVE). / More information2,5030,0075,0075,002,50
REU0805uFissurímetre straight two directions, for measuring vertical movements, horizontal and rotational fissures, cracks, expansion joints, decks or metallic surfaces, bridges, tunnels, dams, etc. with 0.1 mm resolution and range 5cm (x direction) and 2 cm (y direction), made of polyester resistant to mineral and organic acids, alkalis, oxidation and reduction products, organic solvents, insects and microorganisms and sunlight, insoluble in acetone and formic acid. Even mounting adhesive.20,009,00180,00
RE0159uRecognition of an ocular inspection unit building or premises8,0023,10184,80176,008,00
RE0153uDisplacement of a technician (distance intervals of 10 km or fraction)4,0011,3445,3622,001,00
observations:
It is considered independent inspection unit each of the following: every home regardless of the surface; premises for commercial use, warehouse, garage or any other use other than housing on the same level and up to 200 m² of floor area or fraction.
written by Joaquim Iborra Posadas
company: REHABI-LI-TAR. Gestió i promoció de la rehabilitació SLU
update 26/07/2018
zone València
..........
Validated by
profile
Validated date
Edit price