Laminated Material Adhesion

Navigation

Home‎ > ‎

Testing


 

Testing

L-MA uses both a Heated and Non-Heated Adhesion Surface Testing. Our testing process is 150F for one hour and then we raise the temperature by 5 degrees until failure or delamination occurs.

We maintain tested samples for 1 year in a temperature controlled environment and an additional 4 years in bulk storage.

L-MA does not certify the adhesion of any company as we cannot control the adhesive application process on each component. L-MA test individual components and maintains a spot check program to create a QC system for component producers.

For additional questions about our testing you may email your questions and a technical advisor will contact you.