Fan heater thermostat : On demand hot water heater. Fan Heater Thermostat
Thermostat-0152 it took a -long- time (days) to figure out why the system kept dying. I removed all the wires, trimmed them back, re-striped them, still blew. I bought new wire and connected the thermostat directly to the unit and had it sitting on the floor in the basement. That was stable for 2 weeks. It turns out that there is an intermitent short between the blue (common) and red (power) lines. So, even though I had 5-conductor cable in the walls I could only use 4 of them. So, I had to buy a '4 to 5' adaptor (that white box hanging down). It uses the magic of electronics to convert a single wire in to two control lines by making use of a diode pack attached to the thermostat and a control box attached to the HVAC circuit. This let me clip the broken blue wire, use the old 'fan' control line as the new 'common' line, and use the AC line to run both the AC and the heater fan independently. Small compact Thermostat KT 011
KTO 011: Thermostat (normally closed); contact breaker for regulating heaters. KTS 011: Thermostat (normally open); contact maker for regulating of filter fans and heat exchangers or for switching signal devised when temperature limit has been exceeded. See also: carbon sauna heaters cheap night storage heaters testing electric water heater lpg water heaters water heater costs non electric space heater ultimate wood heaters melbourne duct air heater aqua hut water heater enclosure integrated solar water heater |